Rheonik RHM 015 Flow Sensor
The RHM 015 Coriolis sensors offers solutions for the lowest flow rates – for flow control, batching and injections up the highest pressures in industry. Small, compact and highest performance.
- Range: 0.002 kg/min up to 1.2 kg/min
- Pressure: up to 1481 bar (21480 psi)
- Temperature: -196°C (-321°F) up to +210°C (410°F)
- Accuracy: 0.1 % of rate
- Materials: SS 316L / SS 316Ti, Alloy C22 – 2.4602, Super Duplex – 1.4410, Sandvik HP160
- Process Connection: ¼” up to 1″
MFG Part Number | RHM-015 |
Stock | Limited |
The specifications provided are detailed technical information for a flow sensor model, likely the Rheonik RHM series. Here is a summary of the key points:
Flow Specifications
- Nominal Flow (Qnom): 0.6 kg/min (1.32 lb/min)
- Maximum Flow (Qmax): 1.2 kg/min (2.65 lb/min)
- Typical Minimum Flow (Qmin): 0.002 kg/min (0.004 lb/min)
- For serial configurations, flow rates (Qmax, Qnom, Qmin) are 50% of those for the parallel/dual path version.
Temperature and Pressure Ratings
- Fluid Temperature Range: -196°C to +210°C (-320°F to +410°F)
- Note: Refer to the transmitter datasheet for integral transmitter versions.
- Ambient Temperature: -50°C to +80°C (-60°F to +180°F), with a high-temperature version up to +210°C (+410°F).
- Pressure Rating: Up to 1481 bar (21480 psi), material-dependent.
Electrical Connections
- Sensor without Integral Transmitter:
- Standard entry: M20 x 1.5 for JM and SM terminal boxes.
- Optional entries include ½” NPT, M25 x 1.5 (only SM), or ¾” NPT (only SM).
- PM terminal box version: M16 x 1.5 standard.
- Maximum cable length: 100 m (330 ft) to remote RHE transmitter.
Enclosure and Wetted Material Options
- Enclosure Material: Stainless steel 304 (standard), SS 316 (optional), coated aluminum or SS 316 for the terminal box.
- Enclosure Type: IP66, NEMA 4 (standard); optional IP66/67, NEMA 4X.
- Wetted Materials: Various stainless steel options (SS 316L, SS 316Ti) and specialized alloys (SuperDuplex, Alloy C22).
Process Connections and Approvals
- Process Connections: Customizable to various fittings (AnyPipeFit Commitment).
- Pressure Compliance: Follows PED 2014/68/EU Article 4, Section 3.
- Certifications: ATEX, IECEx (Zones 0, 1, 2), North American approvals, ABS.
Testing, Inspection, and Additional Services
- Testing: Hydro tested and calibrated with traceable certification; customized calibration/testing available.
- Additional Services: Project documentation, QA, origin certificates, functional testing, and more.
- Customization Options: Available for machine integration and specific project needs.
Important Notes
- Pressure Drop: Approx. 2 bar (29 psi) for H2O at Qnom in parallel tube sensors; will increase with higher flow rates or in high-pressure models.
- Accuracy at Low Flow: Qmin represents the recommended minimum for accurate measurements; flows below Qmin can be measured but with increased uncertainty (>1% rate).
This data provides critical specifications needed for selecting or integrating the flow sensor in various operational environments and engineering projects.