OMERIN

Industry and Building

Electrical wires, specialised cables and braided insulating sleevings

OMERIN offers a wide range of high-performance products covering a large number of applications in very diverse industries, including the electrothermal construction, electromechanical, chemical, nuclear energy, railway, automotive, naval, aerospace, heavy industry, power plant and other sectors. 

Cables & Braided sleevings

Power, control, communication, instrumentation, ignition, thermocouple and traction cables

Discover all the OMERIN Group products and solutions for high temperature and specific applications. Discover OMERIN product segmentation and download all the documentation for each of our product references: Technical data sheets, REACH, RoHs, CE certificats. Our teams are at your disposal, don’t hesitate to get in touch. 

Aeronautics and Defence

Onboard cables, Avionics cables, Data cables, Miniature thermocouples, Special cables and Harness protection

CGP, a EN 9100 certified subsidiary of the OMERIN Group, is a recognised specialist on the Aeronautics, Defence and Space market. We design and manufacture a complete range of products that meet the specific needs of these high-tech sectors: reduced weight, miniaturisation, ability to withstand severe environments (high temperatures, arc tracking, abrasion, chemical aggression, etc.). Our wires and cables comply with the most demanding international standards EN, MIL, NEMA, SAE, NF. We also develop tailor-made solutions: specialised multifunctional cables and spiral cords. In addition to this offer, the OMERIN Group manufactures flexible heating elements and braided sleevings for specific aeronautics applications.

PRODUCTS
SPECIFICATIONS
ELECTROAIR®
NEMA HP3 ET
Temperature:
- 90°C to + 200°C
Rated voltage:
250 V
Material:
PTFE
Core:
silve- plated copper
ELECTROAIR®
NEMA HP3 E
Temperature:
- 90°C to + 200°C
Rated voltage:
600 V
Material:
PTFE
Core:
silve- plated copper
ELECTROAIR®
NEMA HP3 EE
Temperature:
- 90°C to + 200°C
Rated voltage:
1000 V
Material:
PTFE
Core:
silve- plated copper
ELECTROAIR®
NEMA HP4 KT
Temperature:
- 55°C to + 200°C
Rated voltage:
250 V
Material:
FEP
Core:
silve- plated copper
Resistance:
arc tracking
ELECTROAIR®
NEMA HP4 K
Temperature:
- 55°C to + 200°C
Rated voltage:
600 V
Material:
FEP
Core:
silve- plated copper
Resistance:
arc tracking
ELECTROAIR®
NEMA HP4 KK
Temperature:
- 55°C to + 200°C
Rated voltage:
1000 V
Material:
FEP
Core:
silve- plated copper
Resistance:
arc tracking
ELECTROAIR®
M6BA-A6
Temperature:
- 55°C to + 200°C
Rated voltage:
600 V
Material:
FEP
Core:
silve- plated copper
Shielding:
silver-plated copper braid
Resistance:
arc tracking
ELECTROAIR®
MEEBA-AEE
Temperature:
- 90°C to + 200°C
Rated voltage:
600 V
Material:
PTFE
Core:
silve- plated copper
Shielding:
silver-plated copper braid
ELECTROAIR®
KU 01, 03, 04
Temperature:
- 55°C to + 150°C
Rated voltage:
600 V
Material:
ETFE
Core:
tin-plated copper
ELECTROAIR®
KU 02, 05, 06
Temperature:
- 55°C to + 150°C
Rated voltage:
600 V
Material:
ETFE
Core:
tin-plated copper
Shielding:
tin-plated copper braid
ELECTROAIR®
M7-KU 01
Temperature:
- 55°C to + 150°C
Rated voltage:
600 V
Material:
ETFE
Core:
tin-plated copper
Version:
4x, 5x, 7x
ELECTROAIR®
M7BE-KU 01
Composition:
4 to 7 conductors
Temperature:
- 55°C to + 150°C
Rated voltage:
600 V
Material:
ETFE
Core:
tin-plated copper
Shielding:
tin-plated copper braid
ELECTROAIR®
AGZ 04
Temperature:
- 55°C to + 200°C
Rated voltage:
250 V
Material:
FEP
Core:
silve- plated copper
Resistance:
arc tracking
ELECTROAIR®
AGZ 05
Temperature:
- 55°C to + 200°C
Rated voltage:
600 V
Material:
FEP
Core:
silve- plated copper
Resistance:
arc tracking
ELECTROAIR®
AGZ 06
Temperature:
- 55°C to + 200°C
Rated voltage:
1000 V
Material:
FEP
Core:
silve- plated copper
Resistance:
arc tracking
ELECTROAIR®
M-AGZ 04
Temperature:
- 55°C to + 200°C
Rated voltage:
250 V
Material:
FEP
Core:
silve- plated copper
Version:
twisted (2x, 3x, 4x)
Resistance:
arc tracking
ELECTROAIR®
M-AGZ 05
Temperature:
- 55°C to + 200°C
Rated voltage:
600 V
Material:
FEP
Core:
silve- plated copper
Version:
twisted (2x, 3x, 4x)
Resistance:
arc tracking
ELECTROAIR®
M-AGZ 06
Temperature:
- 55°C to + 200°C
Rated voltage:
1000 V
Material:
FEP
Core:
silve- plated copper
Version:
twisted (2x, 3x, 4x)
Resistance:
arc tracking
ELECTROAIR®
AGZ 55, 67, 79
Temperature:
- 55°C to + 200°C
Rated voltage:
250 V
Material:
FEP
Core:
silve- plated copper
Shielding:
silver-plated copper braid
Resistance:
arc tracking
ELECTROAIR®
AGZ 57, 69, 81, 93
Temperature:
- 55°C to + 200°C
Rated voltage:
600 V
Material:
FEP
Core:
silve- plated copper
Shielding:
silver-plated copper braid
Resistance:
arc tracking
ELECTROAIR®
AGZ 59, 71, 83
Temperature:
- 55°C to + 200°C
Rated voltage:
1000 V
Material:
FEP
Core:
silve- plated copper
Shielding:
silver-plated copper braid
Resistance:
arc tracking
ELECTROAIR®
AGF 05
Temperature:
- 55°C to + 200°C
Rated voltage:
600 V
Material:
FEP
Core:
extra flexible silver-plated copper
Resistance:
arc tracking
ELECTROAIR®
M-AGF 05
Temperature:
- 55°C to + 200°C
Rated voltage:
600 V
Material:
FEP
Core:
extra flexible silver-plated copper
Version:
twisted (2x, 3x, 4x)
Resistance:
arc tracking
ELECTROAIR®
AGF 57, 69, 81, 93
Temperature:
- 55°C to + 200°C
Rated voltage:
600 V
Material:
FEP
Core:
extra flexible silver-plated copper
Shielding:
silver-plated copper braid
Resistance:
arc tracking
ELECTROAIR®
KZ 04, 07
Temperature:
- 90°C to + 200°C, + 260°C
Rated voltage:
250 V
Material:
PTFE
Core:
silver-plated or nickel-plated copper
ELECTROAIR®
KZ 05, 08
Temperature:
- 90°C to + 200°C, + 260°C
Rated voltage:
600 V
Material:
PTFE
Core:
silver-plated or nickel-plated copper
ELECTROAIR®
KZ 06, 09
Temperature:
- 90°C to + 200°C, + 260°C
Rated voltage:
1000 V
Material:
PTFE
Core:
silver-plated or nickel-plated copper
PLASTHERM®
E40-FR , M-E40-FR
Temperature:
- 40°C to + 150°C
Rated voltage:
600 V
Material:
halogen free
Core:
tin-plated copper
PLASTHERM®
M40BE-E40-FR
Temperature:
- 40°C to + 150°C
Rated voltage:
600 V
Material:
halogen free
Core:
tin-plated copper
Shielding:
tin-plated copper braid
PRODUCTS
SPECIFICATIONS
HIFLEX®
AGP400 R
Composition:
400 Hz cable
Temperature:
-40°C to +90°C
Rated voltage:
115/230 V
Material:
Halogen free
Core:
Red copper extra-flexible, class 6
HIFLEX®
AGP400 R 3
Composition:
400 Hz cable
Temperature:
-40°C to +90°C
Rated voltage:
115/230 V
Material:
Halogen free
Core:
Tin plated copper extra-flexible, class 6
HIFLEX®
AGP400 R 6
Composition:
400 Hz cable
Temperature:
-40°C to +90°C
Rated voltage:
115/230 V
Material:
Halogen free
Core:
Red copper extra-flexible, class 6
HIFLEX®
AGP400 M
Composition:
400 Hz cable
Temperature:
-40°C to +90°C
Rated voltage:
115/230 V
Material:
Halogen free
Core:
Red copper extra-flexible, class 6
HIFLEX®
AGP400 M i
Composition:
400 Hz cable
Temperature:
-40°C to +90°C
Rated voltage:
115/230 V
Material:
Halogen free
Core:
Tin plated copper extra-flexible, class 6
HIFLEX®
AGP400 M iT
Composition:
400 Hz cable
Temperature:
-40°C to +90°C
Rated voltage:
115/230 V
Material:
Halogen free
Core:
Tin plated copper extra-flexible, class 6
HIFLEX®
AGP400 M iTN
Composition:
400 Hz cable
Temperature:
-40°C to +90°C
Rated voltage:
115/230 V
Material:
Halogen free
Core:
Tin plated copper extra-flexible, class 6
HIFLEX®
AGP400 F
Composition:
400 Hz cable
Temperature:
-20°C to +90°C
Rated voltage:
115/230 V
Material:
Halogen free
Core:
Red copper flexible, class 5
HIFLEX®
AGP400 F LH
Composition:
400 Hz cable
Temperature:
-30°C to +90°C
Rated voltage:
115/230 V
Core:
Red copper flexible, class 5
HIFLEX®
AGP400 F A
Composition:
400 Hz cable
Temperature:
-20°C to +90°C
Rated voltage:
115/230 V
Material:
Halogen free
Core:
Red copper flexible, class 5
PRODUCTS
SPECIFICATIONS
ELECTROAIR®
EN 2266-003 CF Line
Temperature:
- 55°C to + 200°C
Rated voltage:
600 V
Material:
Polyimide
Core:
nickel-plated copper
ELECTROAIR®
EN 2713-007 CF Line
Temperature:
- 55°C to + 200°C
Rated voltage:
600 V
Material:
Polyimide
Core:
nickel-plated copper
Shielding:
nickel-plated copper spiral shield
ELECTROAIR®
EN 2267-007 DM Line
Temperature:
- 55°C to + 260°C
Rated voltage:
600 V
Material:
Polyimide / PTFE
Core:
nickel-plated copper
Resistance:
arc tracking
ELECTROAIR®
EN 2714-011 DM Line
Temperature:
- 55°C to + 260°C
Rated voltage:
600 V
Material:
Polyimide / PTFE
Core:
nickel-plated copper
Shielding:
nickel-plated copper spiral shield
Resistance:
arc tracking
PRODUCTS
SPECIFICATIONS
ELECTROAIR®
DA6007
Temperature:
- 55°C to + 200°C
Rated voltage:
600 V
Material:
Polyimide / PTFE
Core:
silve- plated copper
ELECTROAIR®
DA6010
Temperature:
- 55°C to + 150°C
Rated voltage:
600 V
Material:
Polyimide / PTFE
Core:
silve- plated copper
Shielding:
tin-plated copper spiral shield
ELECTROAIR®
AH7080
Temperature:
- 55°C to + 150°C
Rated voltage:
600 V
Material:
Polyimide / PTFE
Core:
tin-plated copper
Resistance:
arc tracking
ELECTROAIR®
AH7083
Temperature:
- 55°C to + 150°C
Rated voltage:
600 V
Material:
Polyimide / PTFE / FEP
Core:
tin-plated copper
Shielding:
tin-plated copper spiral shield
Resistance:
arc tracking
ELECTROAIR®
FR
Temperature:
- 65°C to + 310°C
Rated voltage:
600 V
Material:
PTFE / fibre minérale
Core:
nickel-plated copper
Version:
fire resistant
ELECTROAIR®
KQ
Temperature:
- 40°C to + 85°C
Rated voltage:
100, 250, 350, 600 V
Material:
Polyurethane
Version:
improved mechanical strength
Approval:
DGA specifications
CERAFIL®
CN8
Temperature:
- 90°C to + 500°C (peak + 1000°C)
Rated voltage:
150 V
Material:
ceramic
Version:
innovation
Size:
miniature
OMBILIFLEX®
Special multi-function cables
Composition:
umbilical cable
Version:
customized product
Specific:
multi-function ernergy, signal, fluid, traction...
SPIRFLEX®
High performance spiral cables
Composition:
spiral cables
Version:
customized product
Specific:
fitted with or without connectors
PRODUCTS
SPECIFICATIONS
COAXTHERM®
W5BA5 - 50
Temperature:
- 90°C to + 260°C
Impedance:
50 ohms
Material:
PFA
Size:
very small
Use:
space saving
COAXTHERM®
RG 178 BU
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
FEP
Size:
very small
Use:
space saving
COAXTHERM®
RG 178 BU / PFA
Temperature:
- 55°C to + 230°C
Impedance:
50 ohms
Material:
PFA
Size:
very small
Use:
space saving
COAXTHERM®
KX 21A
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
FEP
Size:
very small
Use:
space saving
COAXTHERM®
KX 22A
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
FEP
Size:
small
Use:
space saving
COAXTHERM®
RG 316 U
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
FEP
Size:
small
Use:
space saving
COAXTHERM®
RG 316 U / PFA
Temperature:
- 55°C to + 230°C
Impedance:
50 ohms
Material:
PFA
Size:
small
Use:
space saving
COAXTHERM®
RG 303 U
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
FEP
COAXTHERM®
RG 142 BU
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
FEP
COAXTHERM®
RG 400 U
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
FEP
COAXTHERM®
KX 23
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
PTFE / fiberglass
COAXTHERM®
RG 304 U
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
FEP
COAXTHERM®
RG 115 U
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
PTFE / fiberglass
COAXTHERM®
RG 165 U
Temperature:
- 55°C to + 250°C
Impedance:
50 ohms
Material:
PTFE / fiberglass
COAXTHERM®
RG 393 U
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
FEP
COAXTHERM®
RG 225 U
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
PTFE / fiberglass
COAXTHERM®
KX 24
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
PTFE / fiberglass
COAXTHERM®
W5BA5 - 75
Temperature:
- 90°C to + 260°C
Impedance:
75 ohms
Material:
PFA
Size:
very small
Use:
space saving
COAXTHERM®
RG 179 BU
Temperature:
- 55°C to + 200°C
Impedance:
75 ohms
Material:
FEP
Size:
small
Use:
space saving
COAXTHERM®
RG 179 BU / PFA
Temperature:
- 55°C to + 230°C
Impedance:
75 ohms
Material:
PFA
Size:
small
Use:
space saving
COAXTHERM®
RG 59 MINI HT 200C
Temperature:
- 90°C to + 200°C
Impedance:
75 ohms
Material:
PFA
Size:
small
Use:
space saving
COAXTHERM®
KX 25
Temperature:
- 55°C to + 200°C
Impedance:
75 ohms
Material:
PTFE / fiberglass
COAXTHERM®
KX 6A HT 180C
Temperature:
- 60°C to + 180°C
Impedance:
75 ohms
Material:
silicone
COAXTHERM®
RG 302 U
Temperature:
- 55°C to + 200°C
Impedance:
75 ohms
Material:
FEP
COAXTHERM®
RG 144 U
Temperature:
- 55°C to + 200°C
Impedance:
75 ohms
Material:
PTFE / fiberglass
COAXTHERM®
KX 8 HT 180C
Temperature:
- 60°C to + 180°C
Impedance:
75 ohms
Material:
silicone
COAXTHERM®
RG 180 BU
Temperature:
- 55°C to + 200°C
Impedance:
95 ohms
Material:
FEP
Size:
small
Use:
space saving
COAXTHERM®
RG 180 BU / PFA
Temperature:
- 55°C to + 230°C
Impedance:
95 ohms
Material:
PFA
Size:
small
Use:
space saving
PRODUCTS
SPECIFICATIONS
TWINLINK®
FP
Temperature:
- 55°C to + 200°C
Impedance:
50, 75, 100, 120 ohms
Material:
FEP
Core:
silve- plated copper
Shielding:
silver-plated copper braid
TWINLINK®
FA
Temperature:
- 90°C to + 260°C
Impedance:
50, 75, 100, 120 ohms
Material:
PFA
Core:
silve- plated copper
Shielding:
silver-plated copper braid
ELECTROAIR®
MIL-STD-1553 W WJC
Temperature:
- 65°C to + 200°C
Impedance:
77 ohms
Material:
fluoropolymer / polyimide
Core:
silve- plated copper
Shielding:
silver-plated copper braid
PRODUCTS
SPECIFICATIONS
COUPLIX®
K/KX-M-8, E/EX-M-8
Temperature:
- 90°C to + 500°C (peak + 1000°C)
Couple:
E, K
Material:
ceramic
Version:
thermocouple
Size:
miniature
COUPLIX®
KX-M-EE
Temperature:
- 90°C to + 260°C
Couple:
KX
Material:
Polyimide / PTFE
Version:
thermocouple, inspired of EN 2714
Size:
miniature
PRODUCTS
SPECIFICATIONS
MINOROC®
P
Temperature:
- 40°C to + 80°C
Traction:
150 to 3 500 daN
Material:
thermoplastic
Core:
synthetic polyester fibres
MINOROC®
K
Temperature:
- 40°C to + 80°C
Traction:
1060 to 6000 daN
Material:
thermoplastic
Core:
synthetic aramide fibres
PRODUCTS
SPECIFICATIONS
SILITUBE®
X - FIREPROOF SLEEVING
Temperature:
- 60°C to + 260°C (1 min 1500°C)
Material:
mineral fibre with silicone coating
Version:
improved fire performance
PRODUCTS
SPECIFICATIONS
METALTRESSE®
GTCA
Temperature:
- 60°C to + 200°C
Material:
silver plated copper
Version:
1.5 and 2 µm guaranteed thickness
METALTRESSE®
GTCN
Temperature:
- 60°C to + 250°C
Material:
nickel plated copper
Version:
1.27 µm guaranteed thickness

Special Applications

Miniature ceramic insulated wires +500°C, Traction cables, Cables for solar farms, Cables for submersible pumps, Connected power cords, Special custom-made cables...

Whether it be miniature ceramic insulation conductor wire for spacecraft thrusters, traction cables for anti-helicopter protection at prisons or cables for submersible pumps, the OMERIN Group offers its customers its expertise and total control over the cable manufacturing processes to find solutions for even the most specialised applications. Our design offices are made up of engineers specialised in chemistry of materials, metallurgy, plastics, micro-mechanics, electromagnetic compatibility, data transmission and signals to name but a few, which enables them to quickly find the perfect solution to meet your needs.

PRODUCTS
SPECIFICATIONS
CERAFIL®
CN8
Temperature:
- 90°C to + 500°C (peak + 1000°C)
Rated voltage:
150 V
Material:
ceramic
Version:
innovation
Size:
miniature
PRODUCTS
SPECIFICATIONS
OMBILIFLEX®
Special multi-function cables
Composition:
umbilical cable
Version:
customized product
Specific:
multi-function ernergy, signal, fluid, traction...
PRODUCTS
SPECIFICATIONS
MINOROC®
P
Temperature:
- 40°C to + 80°C
Traction:
150 to 3 500 daN
Material:
thermoplastic
Core:
synthetic polyester fibres
MINOROC®
K
Temperature:
- 40°C to + 80°C
Traction:
1060 to 6000 daN
Material:
thermoplastic
Core:
synthetic aramide fibres
PRODUCTS
SPECIFICATIONS
SPIRFLEX®
High performance spiral cables
Composition:
spiral cables
Version:
customized product
Specific:
fitted with or without connectors
PRODUCTS
SPECIFICATIONS
POWER CONNECT®
Power cords
Composition:
cables with crimped lugs
Version:
customized product
PRODUCTS
SPECIFICATIONS
PROFIPLAST®
PBS-R
Temperature:
- 25°C to + 70°C
Rated voltage:
450/750 V
Material:
atoxic Profiprene
Approval:
AD8 (250 m), ACS
Use:
fresh water
PROFIPLAST®
PBS-R BE
Temperature:
- 25°C to + 70°C
Rated voltage:
450/750 V
Material:
atoxic Profiprene
Shielding:
tin-plated copper braid
Approval:
AD8 (250 m), ACS
Use:
fresh water
PROFIPLAST®
PBS-P
Temperature:
- 25°C to + 70°C
Rated voltage:
450/750 V
Material:
atoxic Profiprene
Version:
flat cable
Approval:
AD8 (250 m), ACS
Use:
fresh water
PROFIPLAST®
PBS-SUB
Temperature:
- 25°C to + 70°C
Rated voltage:
450/750 V
Material:
Profiprene
Version:
450 m - 45 bars
Approval:
AD8 (450 m)
Use:
deep water
PROFIPLAST®
PBS-USE
Temperature:
- 25°C to + 70°C
Rated voltage:
450/750 V
Material:
Profiprene
Approval:
AD8 (250 m)
Use:
waste water
PROFIPLAST®
PBS-USE + Bearer cable
Temperature:
- 25°C to + 70°C
Rated voltage:
450/750 V
Material:
Profiprene
Version:
with bearer
Approval:
AD8 (250 m)
Use:
waste water
PROFIPLAST®
PBS-PLUS
Temperature:
- 40°C to + 80°C
Rated voltage:
450/750 V
Material:
Profiprene
Approval:
AD8 (250 m)
Use:
agressive environment
PROFIPLAST®
PBS-SEA
Temperature:
- 25°C to + 70°C
Rated voltage:
450/750 V
Material:
Profiprene
Approval:
AD8 (250 m)
Use:
marine environment
PROFIPLAST®
PBS-SPOT
Temperature:
- 25°C to + 70°C
Rated voltage:
450/750 V
Material:
Profiprene
Approval:
AD8 (100 m)
Use:
swimming pool
PROFIPLAST®
PBS-POOL
Temperature:
- 25°C to + 70°C
Rated voltage:
300/500 V
Material:
Profiprene
Approval:
AD8 (100 m)
Use:
robotic pool cleaners
PROFIPLAST®
PBS-FLOT
Temperature:
- 25°C to + 70°C
Rated voltage:
300/500 V
Material:
Profiprene
Version:
floating cable
Approval:
AD8 (100 m)
Use:
robotic pool cleaners
PROFIPLAST®
PBS-W
Temperature:
- 25°C to + 70°C
Rated voltage:
450/750 V
Material:
atoxic Profiprene
Approval:
AD8 (250 m), ACS
Use:
agro-food industry
PROFIPLAST®
PBS-M BE
Temperature:
- 25°C to + 70°C
Rated voltage:
300/300 V
Material:
Profiprene
Shielding:
tin-plated copper braid
Approval:
AD8 (100 m)
Use:
measuring devices
PROFIPLAST®
PBS-GARDEN
Temperature:
- 40°C to + 60°C
Rated voltage:
300/300 V, 450/750 V
Material:
PEHD
Version:
buried installations
Use:
spraying control systems
PRODUCTS
SPECIFICATIONS
SOLARPLAST®
H1Z2Z2-K
Temperature:
- 40°C to + 90°C
Rated voltage:
1.0/1.0 kV A.C
Material:
halogen free
Version:
double insulation
Approval:
EN 50618 (Lloyd's Register)
SOLARPLAST®
TWIN H1Z2Z2-K
Temperature:
- 40°C to + 90°C
Rated voltage:
1.0/1.0 kV A.C
Material:
halogen free
Version:
double insulation, 2 conductors
Approval:
EN 50618 (Lloyd's Register)
PRODUCTS
SPECIFICATIONS
ODIOSIS®
HP-M
Temperature:
- 5°C to + 70°C
Material:
PVC
Version:
flat cable
Approval:
RPC EN 50575
ODIOSIS®
HP-R
Temperature:
- 5°C to + 70°C
Material:
PVC
Approval:
RPC EN 50575
ODIOSIS®
HP-GARDEN
Composition:
2x2.5 mm²
Temperature:
- 5°C to + 70°C
Rated voltage:
300V
Material:
polyéthylène
Use:
outside or buried
ODIOSIS®
MIC
Composition:
1 to 5 conductors 0.22 mm²
Temperature:
- 5°C to + 70°C
Material:
extra flexible PVC
Core:
flexible bare copper
Shielding:
bare copper braid
ODIOSIS®
Audio Modulation XP
Composition:
2x0.34 mm²
Temperature:
- 5°C to + 70°C
Impedance:
75 ohms
Material:
PVC
Core:
flexible tin-plated copper
Version:
screened
ODIOSIS®
Audio Modulation MP
Composition:
2 pairs 0.5 mm²
Temperature:
- 5°C to + 70°C
Impedance:
75 ohms
Material:
PVC
Core:
flexible tin-plated copper
Version:
each pair screened
ODIOSIS®
V2AN
Composition:
1 to 5 coaxial cables
Temperature:
- 5°C to + 70°C
Impedance:
75 ohms
Material:
PVC
Core:
flexible tin-plated copper
Shielding:
tin-plated copper braid
PRODUCTS
SPECIFICATIONS
PROFIPLAST®
FLEX Y
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V, 450/750 V
Material:
extra flexible PVC
Core:
classe 6, extra flexible
PROFIPLAST®
FLEX Yw
Temperature:
- 25°C to + 105°C
Rated voltage:
300/500 V, 450/750 V
Material:
extra flexible PVC
Core:
classe 6, extra flexible
PROFIPLAST®
07V-K6 HT
Temperature:
- 25°C to + 105°C
Rated voltage:
450/750 V
Material:
extra flexible PVC
Core:
classe 6, extra flexible
PROFIPLAST®
FLEX YY
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V
Material:
extra flexible PVC
Core:
classe 6, extra flexible
PROFIPLAST®
FLEX YwYw
Temperature:
- 25°C to + 105°C
Rated voltage:
300/500 V
Material:
extra flexible PVC
Core:
classe 6, extra flexible
ROBOFLEX®
41Qb
Temperature:
- 50°C to + 105°C
Rated voltage:
600/1000 V
Material:
TPE / Polyurethane
Core:
classe 6, extra flexible
Version:
double insulation
ROBOFLEX®
MQb-41
Temperature:
- 50°C to + 105°C
Rated voltage:
300/500 V, 450/750 V
Material:
TPE / Polyurethane
Core:
classe 6, extra flexible
ROBOFLEX®
MQbBE-41
Temperature:
- 50°C to + 105°C
Rated voltage:
300/500 V, 450/750 V
Material:
TPE / Polyurethane
Core:
classe 6, extra flexible
Shielding:
tin-plated copper braid
PRODUCTS
SPECIFICATIONS
PROFIPLAST®
03ET-F
Temperature:
- 50°C to + 125°C
Rated voltage:
300/300 V
Material:
elastomer thermoplastic
PROFIPLAST®
05ET-F
Temperature:
- 50°C to + 125°C
Rated voltage:
300/500 V
Material:
elastomer thermoplastic
PROFIPLAST®
03ET-F BE
Temperature:
- 50°C to + 125°C
Rated voltage:
300/300 V
Material:
elastomer thermoplastic
Shielding:
tin-plated copper braid
PROFIPLAST®
05ET-F BE
Temperature:
- 50°C to + 125°C
Rated voltage:
300/500 V
Material:
elastomer thermoplastic
Shielding:
tin-plated copper braid
PROFIPLAST®
CLIM-BT HT
Temperature:
- 40°C to + 105°C
Rated voltage:
450/750 V
Material:
PVC
PRODUCTS
SPECIFICATIONS
PLASTHERM®
M-RY, M-R31, M-R39, M-R7
Material:
PVC (M-RY), PEHD (M-R31), PP (M-R39) or ETFE (M-R7)
Core:
from Ø 20/100 mm (0.03 mm²)
Size:
thin insulation
Use:
electric cables for ignition systems

Automotive and Electric Mobility

High-voltage cables for electric and hybrid vehicles, Low-voltage cables and Braided insulated sleeving for areas exposed to high temperatures or confined spaces

The OMERIN Group, an innovative player in the Automotive and E-mobility sector, is the world’s leading manufacturer of silicone elastomer-insulated wires and cables.This material offers exceptional insulating capabilities and good resistance to thermal shocks. With the development of electric and hybrid vehicles, the engineers from the OMERIN Group have developed the high-voltage cables FHL2G and FHLR2GCB2G until 1000 VAC / 1500 VDC. The silicone material employed led the SILICABLE ® FHLR2GCB2G cable extremely flexible and offers exceptional insulation capabilities and good resistance to high temperatures and thermal shocks. We also offer wires, cables and braided insulated sleevings for high-temperature zones, harnesses for passenger compartments, battery chargers, braking systems and other specialised systems in compliance with the international standard ISO 6722. In addition to this offer, the OMERIN Group manufactures tubes and extruded insulated sleevings for specialised Automobile applications.

PRODUCTS
SPECIFICATIONS
PROFIPLAST®
48 AU IN
Temperature:
-40°C to +85°C
Rated voltage:
600 V
Material:
PVC
PROFIPLAST®
48 AU IN HT
Temperature:
-40°C to +105°C
Rated voltage:
600 V
Material:
PVC 105°C
PROFIPLAST®
48 AU IN THT
Temperature:
-40°C to +125°C
Rated voltage:
600 V
Material:
PVC 125°C
PROFIPLAST®
48 AU Ird
Temperature:
-40°C to +85°C
Rated voltage:
600 V
Material:
PVC
Version:
thin wall insulation
PROFIPLAST®
48 AU Ird HT
Temperature:
-40°C to +105°C
Rated voltage:
600 V
Material:
PVC 105°C
Version:
thin wall insulation
PROFIPLAST®
48 AU Ird THT
Temperature:
-40°C to +125°C
Rated voltage:
600 V
Material:
PVC 125°C
Version:
thin wall insulation
PLASTHERM®
FLRY
Temperature:
-40°C to +105°C
Material:
PVC 105°C
Core:
ISO 6722-1, ISO 19642-3 type A : FLRY-A & type B : FLRY-B
Specific:
ISO 19642-3
PLASTHERM®
FLRYW
Temperature:
-40°C to +125°C
Material:
PVC 125°C
Core:
ISO 6722-1, ISO 19642-3 type A : FLRYW-A & type B : FLRYW-B
Specific:
ISO 19642-3
PLASTHERM®
FLR11Y
Temperature:
-40°C to +150°C
Material:
TPE-U
Core:
ISO 6722-1, ISO 19642-3 type A : FLR11Y-A & type B : FLR11Y-B
Specific:
ISO 19642-3
SILIFLON®
FLR7Y
Temperature:
- 40°C to + 175°C
Material:
ETFE
Core:
ISO 6722-1, ISO 19642-3 type A : FLR7Y-A & type B : FLR7Y-B
Specific:
ISO 19642-3
SILIFLON®
FLR6Y
Temperature:
- 40°C to + 210°C
Material:
FEP
Core:
ISO 6722-1, ISO 19642-3 type A : FLR6Y-A & type B : FLR6Y-B
Specific:
ISO 19642-3
SILIFLON®
FLR51Y
Temperature:
- 40°C to + 260°C
Material:
PFA
Core:
ISO 6722-1, ISO 19642-3 type A : FLR51Y-A & type B : FLR51Y-B
Specific:
ISO 19642-3
SILICABLE®
FL2G
Temperature:
- 40°C to + 200°C
Material:
silicone
Core:
ISO 6722-1, ISO 19642-3 type B : FL2G-B & type C : FL2G-C
Version:
Halogen free
Specific:
ISO 19642-3
PLASTHERM®
FLR2X
Temperature:
- 40°C to + 125°C
Material:
PE-X
Core:
ISO 6722-1, ISO 19642-3 type A : FLR2X-A & type B : FLR2X-B
Version:
Halogen free
Specific:
ISO 19642-3
PLASTHERM®
FLR41X
Temperature:
- 40°C to + 150°C
Material:
PO-X
Core:
ISO 6722-1, ISO 19642-3 type A : FLR41X-A & type B : FLR41X-B
Version:
Halogen free
Specific:
ISO 19642-3
PRODUCTS
SPECIFICATIONS
SILICABLE®
FHL2G-C
Temperature:
- 40°C to + 180°C, Class E
Rated voltage:
1000 VAC / 1500 VDC
Material:
silicone
Core:
ISO 6722-1, ISO 19642-5 & EN 13602
Version:
Halogen free
Specific:
ISO 19642-5
SILICABLE®
FHLR2GCB2G-C Mono
Temperature:
- 40°C to + 180°C, Class E
Rated voltage:
1000 VAC / 1500 VDC
Material:
silicone
Core:
ISO 6722-1, ISO 19642-5 & EN 13602
Shielding:
double shielding, single core version
Version:
Halogen free
Specific:
ISO 19642-9
SILICABLE®
FHLR2GCB2G-C Multi
Temperature:
- 40°C to + 180°C, Class E
Rated voltage:
600 VAC / 900 VDC (cross sections < 10 mm²), 1000 VAC / 1500 VDC (cross sections > 6 mm²)
Material:
silicone
Core:
ISO 6722-1, ISO 19642-5 & EN 13602
Shielding:
double shielding, multicore version
Version:
Halogen free
Specific:
ISO 19642-9
SILICABLE®
FHLR6YBCF2G Hybride
Temperature:
- 40°C to + 180°C, Class E
Rated voltage:
600 VAC / 900 VDC
Material:
silicone
Core:
ISO 6722-1, ISO 19642-5
Shielding:
double shielding + twisted shielded pair 2x0.5 mm²
Version:
Specific composition 2x4 + 0.5 mm²
Specific:
ISO 19642-9
SILICABLE®
FHLR2G-C
Temperature:
- 40°C to + 180°C, Class E
Rated voltage:
600 VAC / 900 VDC (cross sections < 10 mm²), 1000 VAC / 1500 VDC (cross sections > 6 mm²)
Material:
silicone
Core:
ISO 6722-1, ISO 19642-5 & EN 13602
Version:
Halogen free
Specific:
ISO 19642-5
SILICABLE®
FHLR2G LV216
Temperature:
- 40°C to + 180°C, Class E
Rated voltage:
600 VAC / 1000 VDC
Material:
silicone
Core:
ISO 6722-1 & EN 13602
Version:
Halogen free
Specific:
LV 216 - 2
SILICABLE®
FHLR2GCB2G LV216 Mono
Temperature:
- 40°C to + 180°C, Class E
Rated voltage:
600 VAC / 900 VDC (cross sections < 10 mm²), 1000 VAC / 1500 VDC (cross sections > 6 mm²)
Material:
silicone
Core:
ISO 6722-1 & EN 13602
Shielding:
double shielding, single core version
Version:
Halogen free
Specific:
LV 216 - 2
SILICABLE®
FHLR2G2G-C Multi
Temperature:
- 40°C to + 180°C, Class E
Rated voltage:
600 VAC / 900 VDC (cross sections < 10 mm²), 1000 VAC / 1500 VDC (cross sections > 6 mm²)
Material:
silicone
Core:
ISO 6722-1, ISO 19642-5 & EN 13602
Version:
Halogen free
Specific:
ISO 19642-9
SILICABLE®
FHLR2GCB2G LV216 Multi
Temperature:
- 40°C to + 180°C, Class E
Rated voltage:
600 VAC / 1000 VDC
Material:
silicone
Core:
ISO 6722-1, LV 216-2 & EN 13602
Shielding:
double shielding, multicore version
Version:
Halogen free
Specific:
LV 216 - 2
PRODUCTS
SPECIFICATIONS
FLEXBAT®
ST
Temperature:
- 15°C to + 70°C
Rated voltage:
450/750 V
Material:
extra flexible PVC
Core:
IEC 60228, extra flexible
FLEXBAT®
HT
Temperature:
- 25°C to + 105°C
Rated voltage:
450/750 V
Material:
extra flexible PVC
Core:
IEC 60228, extra flexible
FLEXBAT®
THT
Temperature:
- 25°C to + 125°C
Rated voltage:
450/750 V
Material:
TPE 125°C
Core:
IEC 60228, extra flexible
FLEXBAT®
DI LR HT
Temperature:
- 40°C to + 105°C
Rated voltage:
600/600 V
Material:
extra flexible PVC
Core:
ISO 6722 type B & C
Version:
double insulation
TWINBAT®
RN
Temperature:
- 15°C to + 70°C
Rated voltage:
450/750 V
Material:
extra flexible PVC
Core:
IEC 60228, extra flexible
Version:
2-conductor
PRODUCTS
SPECIFICATIONS
PROFIPLAST®
CSA
Temperature:
- 15°C to + 70°C
Rated voltage:
600 V
Material:
PVC
PROFIPLAST®
CSA Ird
Temperature:
- 15°C to + 70°C
Rated voltage:
600 V
Material:
PVC
Version:
thin wall insulation
PROFIPLAST®
CSA ADR
Temperature:
- 15°C to + 70°C
Rated voltage:
600 V
Material:
PVC ADR
PROFIPLAST®
CSA ADR Ird
Temperature:
- 15°C to + 70°C
Rated voltage:
600 V
Material:
PVC ADR
Version:
thin wall insulation
PROFIPLAST®
ADR
Temperature:
- 15°C to + 70°C
Rated voltage:
300 V
Material:
PVC ADR
Version:
flat cable
PRODUCTS
SPECIFICATIONS
SILIGAINE®
13F1
Temperature:
- 30°C to + 155°C, Class F
Dielectric strength:
> 1 kV (dry)
Material:
fiberglass with PU coating
SILIGAINE®
13F3
Temperature:
- 30°C to + 155°C, Class F
Dielectric strength:
3 kV (dry, central value)
Material:
fiberglass with PU coating
SILIGAINE®
13F4
Temperature:
- 30°C to + 155°C, Class F
Dielectric strength:
> 4 kV (dry)
Material:
fiberglass with PU coating
SILIGAINE®
16F2
Temperature:
- 30°C to + 155°C, Class F
Dielectric strength:
1.8 kV (dry, central value)
Material:
fiberglass with acrylic coating
SILIGAINE®
16F3
Temperature:
- 30°C to + 155°C, Class F
Dielectric strength:
3.3 kV (dry, central value)
Material:
fiberglass with acrylic coating
SILIGAINE®
16F7 UL
Temperature:
- 30°C to + 155°C, Class F
Dielectric strength:
7 kV (dry, central value)
Material:
fiberglass with acrylic coating
Approval:
UL
SILIGAINE®
15C1.5
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
1.5 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C2
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
2.5 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C3
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 3 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C3-UV
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 3 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C4
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 4 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C4.d
Temperature:
- 60°C to + 200°C, Class H
Dielectric strength:
> 4 kV (dry)
Material:
fiberglass (double insulation)
Version:
abrasion resistance
SILIGAINE®
15C5
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 5 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C5-E EXTENSIBLE
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 5 kV (dry)
Material:
fiberglass with silicone coating
Version:
expandable
SILIGAINE®
15C7 GRADE A UL
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 7 kV (dry)
Material:
fiberglass with silicone coating
Approval:
UL
SILIGAINE®
15C10
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 10 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
TN
Temperature:
-50°C to +150°C
Material:
single-filament polyester
Version:
expandable
SILIGAINE®
TN FR
Temperature:
-50°C to +150°C
Material:
single-filament polyester
Version:
expandable
Approval:
EN 45545-2
Fire-smoke:
Flame resistant
SILIGAINE®
TN FR TWIST
Temperature:
-50°C to +150°C
Material:
single-filament polyester
Version:
expandable and self wrapping
Approval:
EN 45545-2
Fire-smoke:
Flame resistant
SILIGAINE®
TNL FR TWIST
Temperature:
-50°C to +150°C
Material:
single-filament polyester
Version:
expandable and self wrapping
Approval:
EN 45545-2
Fire-smoke:
Flame resistant

Building

For residential cabling, public and high-rise buildings

The OMERIN Group has established its reputation in the manufacturing of power and communication cables for the building market. Our cable range PROFIPLAST® (thermoplastic-insulated wires and cables), LUMIPLAST® (wires and cables for lighting systems), MULTI-VX® (hybrid data and power cables), BIO-HABITAT® (wires and cables for a home without electromagnetic interference), TS CABLES® (coaxial and data cables), TS COM 900® (telephone cables for very high-speed reception ), TS LAN® (computer cables for VDI networks) offer comprehensive solutions for the specific needs of the building industry. Our wires and cables comply with the European standards in the building sector, and in particular with the new requirements for Construction Product Regulations based on Euroclasses Eca, Dca-s2,d2,a1 and Cca-s1a,d1,a1. We also offer low-pressure hoses for sanitary, heating and HVAC applications.

PRODUCTS
SPECIFICATIONS
PYRISOL®
500 EN CR1-C1
Rated voltage:
300/500 V
Material:
fire resistant
PYRITEL®
100 EN CR1-C1
Rated voltage:
100/170 V
Material:
fire resistant
Version:
sreened
PYRISOL®
500 ENA CR1-C1
Rated voltage:
300/500 V
Material:
fire resistant
Version:
armoured
PYRISOL®
500 BEL
Rated voltage:
300/500 V
Material:
fire resistant
PYRITEL®
100 BEL
Rated voltage:
100/170 V
Material:
fire resistant
Version:
sreened
SILIFLAM®
500 TX-K CR1-C1
Rated voltage:
300/500 V
Material:
fire resistant
Core:
flexible
SILIFLAM®
500 TX-K BE CR1-C1
Rated voltage:
300/500 V
Material:
fire resistant
Core:
flexible
Shielding:
tin-plated copper braid
SILIFLAM®
500 TEL-EI/EG CR1-C1
Rated voltage:
100/170 V
Material:
fire resistant
Version:
sreened
ELECTROFEU®
ET2002SH CR1-C1 1000V
Rated voltage:
600/1000 V
Material:
fire resistant
PRODUCTS
SPECIFICATIONS
PROFIPLAST®
CABLETTE
Material:
stranded bare copper core
Resistance:
hydrocarbons
PROFIPLAST®
H05V-U
Temperature:
- 5°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Approval:
RPC EN 50575, <HAR>
PROFIPLAST®
H05V2-U
Temperature:
- 5°C to + 90°C
Rated voltage:
300/500 V
Material:
PVC
Approval:
RPC EN 50575, <HAR>
PROFIPLAST®
H07V-U
Temperature:
- 5°C to + 70°C
Rated voltage:
450/750 V
Material:
PVC
Approval:
RPC EN 50575, <HAR>
PROFIPLAST®
H07V2-U
Temperature:
- 5°C to + 90°C
Rated voltage:
450/750 V
Material:
PVC
Approval:
<HAR>
PROFIPLAST®
H07V-R
Temperature:
- 5°C to + 70°C
Rated voltage:
450/750 V
Material:
PVC
Approval:
RPC EN 50575, <HAR>
PROFIPLAST®
07V2-R
Temperature:
- 5°C to + 90°C
Rated voltage:
450/750 V
Material:
PVC
PROFIPLAST®
H05V-K
Temperature:
- 5°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Approval:
RPC EN 50575, <HAR>
PROFIPLAST®
H05V2-K
Temperature:
- 5°C to + 90°C
Rated voltage:
300/500 V
Material:
PVC
Approval:
<HAR>
PROFIPLAST®
H07V-K
Temperature:
- 5°C to + 70°C
Rated voltage:
450/750 V
Material:
PVC
Approval:
RPC EN 50575, <HAR>
PROFIPLAST®
H07V2-K
Temperature:
- 5°C to + 90°C
Rated voltage:
450/750 V
Material:
PVC
Approval:
RPC EN 50575, <HAR>
PROFIPLAST®
SV-HT 105
Temperature:
- 25°C to + 105°C
Rated voltage:
300/500 V, 450/750 V
Material:
PVC
PROFIPLAST®
SV-THT 125
Temperature:
- 25°C to + 125°C
Rated voltage:
300/500 V, 450/750 V
Material:
PVC
PROFIPLAST®
05Z1-K
Temperature:
- 5°C to + 70°C
Rated voltage:
300/500 V
Material:
halogen free
PROFIPLAST®
07Z1-K
Temperature:
- 5°C to + 70°C
Rated voltage:
450/750 V
Material:
halogen free
PROFIPLAST®
FR-N07V-AR
Temperature:
- 5°C to + 70°C
Rated voltage:
450/750 V
Material:
PVC
Core:
aluminium (16, 25, 35 mm²)
Approval:
RPC EN 50575, NF USE
PROFIPLAST®
TWISTE
Temperature:
- 5°C to + 70°C
Rated voltage:
450/750 V
Material:
PVC
Version:
twisted
PROFIPLAST®
FR-N05VV-U
Temperature:
- 5°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Approval:
NF USE
PROFIPLAST®
H03VV-F
Temperature:
- 5°C to + 60°C
Rated voltage:
300/300 V
Material:
PVC
Approval:
<HAR>
PROFIPLAST®
H03V2V2-F
Temperature:
- 5°C to + 90°C
Rated voltage:
300/300 V
Material:
PVC
PROFIPLAST®
H05VV-F
Temperature:
- 5°C to + 60°C
Rated voltage:
300/500 V
Material:
PVC
Approval:
<HAR>
PROFIPLAST®
H05V2V2-F
Temperature:
- 5°C to + 90°C
Rated voltage:
300/500 V
Material:
PVC
Approval:
<HAR>
PROFIPLAST®
CSR
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
PROFIPLAST®
CSR-HT
Temperature:
- 25°C to + 105°C
Rated voltage:
600/1000 V
Material:
PVC
PROFIPLAST®
CSR LSZH
Temperature:
- 20°C to + 70°C
Rated voltage:
300/500 V
Material:
halogen free
PROFIPLAST®
CSR BPA
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Version:
sreened
PROFIPLAST®
CSR BE
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Shielding:
tin-plated copper braid
PROFIPLAST®
03Z1Z1-F
Temperature:
- 5°C to + 60°C
Rated voltage:
300/300 V
Material:
halogen free
PROFIPLAST®
05Z1Z1-F
Temperature:
- 5°C to + 60°C
Rated voltage:
300/500 V
Material:
halogen free
PROFIPLAST®
H03VVH2-F
Temperature:
- 5°C to + 60°C
Rated voltage:
300/300 V
Material:
PVC
Version:
flat cable
Approval:
<HAR>
LUMIPLAST®
03VH-H
Temperature:
- 5°C to + 60°C
Rated voltage:
300/300 V
Material:
PVC
Version:
2-conductor
PROFIPLAST®
U1000 R02V
Temperature:
- 25°C to + 90°C
Rated voltage:
600/1000 V
Material:
PVC
Approval:
RPC EN 50575
BIO-HABITAT®
H07V-U BPA
Temperature:
- 5°C to + 70°C
Rated voltage:
450/750 V
Material:
PVC
Version:
screened
Approval:
RPC EN 50575
BIO-HABITAT®
H07V-R BPA
Temperature:
- 5°C to + 70°C
Rated voltage:
450/750 V
Material:
PVC
Version:
screened
Approval:
RPC EN 50575
BIO-HABITAT®
H07Z-U BPA
Temperature:
- 5°C to + 70°C
Rated voltage:
450/750 V
Material:
halogen free
Version:
screened
Approval:
RPC EN 50575
BIO-HABITAT®
05VV-U BPA
Temperature:
- 5°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Version:
screened
Approval:
RPC EN 50575
BIO-HABITAT®
H05VV-F BPA
Temperature:
- 5°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Version:
screened
Approval:
RPC EN 50575
PROFIPLAST®
10V2-K
Temperature:
- 25°C to + 105°C
Rated voltage:
600/1000 V
Material:
PVC 105°C
PROFIPLAST®
10Z1-K
Temperature:
- 25°C to + 105°C
Rated voltage:
600/1000 V
Material:
halogen free
PROFIPLAST®
1000 YY
Temperature:
- 15°C to + 70°C
Rated voltage:
600/1000 V
Material:
PVC
PROFIPLAST®
1000 YCY
Temperature:
- 15°C to + 70°C
Rated voltage:
600/1000 V
Material:
PVC
Shielding:
tin-plated copper braid
PROFIPLAST®
1000 YwCYw
Temperature:
- 25°C to + 105°C
Rated voltage:
600/1000 V
Material:
PVC
Shielding:
tin-plated copper braid
PROFIPLAST®
1000 YCY LSLH
Temperature:
- 15°C to + 70°C
Rated voltage:
600/1000 V
Material:
PVC LSLH
Shielding:
tin-plated copper braid
PROFIPLAST®
1000 LSZH
Temperature:
- 15°C to + 70°C
Rated voltage:
600/1000 V
Material:
halogen free
PROFIPLAST®
1000 LSZH BE
Temperature:
- 15°C to + 70°C
Rated voltage:
600/1000 V
Material:
halogen free
Shielding:
tin-plated copper braid
PROFIPLAST®
1000 YCYRHC1
Temperature:
- 15°C to + 70°C
Rated voltage:
600/1000 V
Material:
PVC HR
Shielding:
tin-plated copper braid
Version:
oil resitant
PROFIPLAST®
1000 YCY LSLH C1
Temperature:
- 5°C to + 60°C
Rated voltage:
600/1000 V
Material:
PVC LSLH
Shielding:
tin-plated copper braid
PROFIPLAST®
1000 2YSLCY-J
Temperature:
- 5°C to + 70°C
Rated voltage:
600/1000 V
Material:
PVC
Version:
shielded (tape and braid)
PROFIPLAST®
1000 GVS RH
Temperature:
- 20°C to + 60°C
Rated voltage:
600/1000 V
Material:
PVC HR
Version:
tin-plated copper
Resistance:
hydrocarbons
PROFIPLAST®
07V-K6 HT
Temperature:
- 25°C to + 105°C
Rated voltage:
450/750 V
Material:
extra flexible PVC
Core:
classe 6, extra flexible
PRODUCTS
SPECIFICATIONS
PROFIPLAST®
LiY
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
PROFIPLAST®
LiYw
Temperature:
- 25°C to + 105°C
Rated voltage:
300/500 V
Material:
PVC
PROFIPLAST®
LiYY
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
PROFIPLAST®
LiYwYw
Temperature:
- 25°C to + 105°C
Rated voltage:
300/500 V
Material:
PVC
PROFIPLAST®
LiYY P
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Version:
multi-pair
PROFIPLAST®
LiYY BPA
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Version:
sreened
PROFIPLAST®
LiYCY
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Shielding:
tin-plated copper braid
Approval:
RPC EN 50575
PROFIPLAST®
LiYwCYw
Temperature:
- 25°C to + 105°C
Rated voltage:
300/500 V
Material:
PVC
Shielding:
tin-plated copper braid
PROFIPLAST®
LiYCY P
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Shielding:
tin-plated copper braid
Version:
multi-pair
PROFIPLAST®
P-MKE
Temperature:
- 25°C to + 105°C
Rated voltage:
500 V
Material:
PVC
Core:
tin-plated copper
Shielding:
tin-plated copper braid
PROFIPLAST®
P-MKA
Temperature:
- 25°C to + 105°C
Rated voltage:
500 V
Material:
PVC
Core:
tin-plated copper
PROFIPLAST®
KY 30
Temperature:
- 20°C to + 105°C
Rated voltage:
250 Vca / 350 Vcc
Material:
PVC
PROFIPLAST®
KY 33 A
Temperature:
- 20°C to + 105°C
Rated voltage:
750 Vca / 1000 Vcc
Material:
PVC
PRODUCTS
SPECIFICATIONS
PRODUCTS
SPECIFICATIONS
TS LAN®
Cat 5e U/UTP LSZH
Temperature:
- 20°C to + 70°C
Impedance:
100 ohms
Material:
halogen free
Approval:
RPC EN 50575
TS LAN®
Cat 5e F/UTP LSZH
Temperature:
- 20°C to + 70°C
Impedance:
100 ohms
Material:
halogen free
Version:
sreened
Approval:
RPC EN 50575
TS LAN®
Cat 6 U/UTP LSZH
Temperature:
- 20°C to + 70°C
Impedance:
100 ohms
Material:
halogen free
Approval:
RPC EN 50575
TS LAN®
Cat 6 F/UTP LSZH
Temperature:
- 20°C to + 70°C
Impedance:
100 ohms
Material:
halogen free
Version:
sreened
Approval:
RPC EN 50575 (Dca)
TS LAN®
Cat 6 SF/UTP LSZH
Temperature:
- 20°C to + 70°C
Impedance:
100 ohms
Material:
halogen free
Version:
screened and shielded
Approval:
RPC EN 50575
TS LAN®
Cat 6 U/FTP LSZH
Temperature:
- 20°C to + 70°C
Impedance:
100 ohms
Material:
halogen free
Version:
screened
Approval:
RPC EN 50575
TS LAN®
Cat 6A F/UTP LSZH
Temperature:
- 20°C to + 70°C
Impedance:
100 ohms
Material:
halogen free
Version:
screened
Approval:
RPC EN 50575 (Dca)
TS LAN®
Cat 6A U/FTP LSZH
Temperature:
- 20°C to + 70°C
Impedance:
100 ohms
Material:
halogen free
Version:
screened
Approval:
RPC EN 50575 (Dca)
TS LAN®
Cat 6A F/FTP LSZH
Temperature:
- 20°C to + 70°C
Impedance:
100 ohms
Material:
halogen free
Version:
screened
Approval:
RPC EN 50575 (Dca)
TS LAN®
Cat 6A SF/UTP LSZH
Temperature:
- 20°C to + 70°C
Impedance:
100 ohms
Material:
halogen free
Version:
screened and shielded
TS LAN®
Cat 7 S/FTP LSZH
Temperature:
- 20°C to + 70°C
Impedance:
100 ohms
Material:
halogen free
Version:
screened and shielded
Approval:
RPC EN 50575 (Dca)
TS LAN®
Cat 7A S/FTP LSZH
Temperature:
- 20°C to + 70°C
Impedance:
100 ohms
Material:
halogen free
Version:
screened and shielded
Approval:
RPC EN 50575 (Dca)
TS LAN®
Cat 6A SF/UTP LSZH
Temperature:
- 20°C to + 70°C
Impedance:
100 ohms
Material:
halogen free
Version:
screened and shielded
PRODUCTS
SPECIFICATIONS
TEXALARM®
MULTI EV6S CCA
Temperature:
- 30°C to + 80°C
Material:
PVC
Core:
copper plated aluminium
Approval:
RPC EN 50575
TEXALARM®
MULTI EV6S
Temperature:
- 30°C to + 80°C
Material:
PVC
Core:
bare copper
TEXALARM®
MONO EV6R CCA
Temperature:
- 30°C to + 80°C
Material:
PVC
Core:
copper plated aluminium
Approval:
RPC EN 50575
TEXALARM®
MONO EV6R
Temperature:
- 30°C to + 80°C
Material:
PVC
Core:
bare copper
Approval:
RPC EN 50575
PRODUCTS
SPECIFICATIONS
VIDEOCOAX®
KX 6A
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Approval:
RPC EN 50575
VIDEOCOAX®
RG 59 BU
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Approval:
RPC EN 50575
VIDEOCOAX®
KX 8 (RG 11/U)
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Approval:
RPC EN 50575
VIDEOCOAX®
TRIAXIAL KX 8
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Use:
long distance until 800 m
VIDEOCOAX®
75
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Use:
long distance until 500 m
COAXFLASH®
75
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Version:
wide range of colours
Use:
long distance until 500 m
VIDEOCOAX®
100
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Use:
very long distance until 1500 m
VIDEOCOAX®
RG 59 MINI
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Size:
small
Use:
space saving
VIDEOCOAX®
RG 6 LSZH
Temperature:
- 40°C to + 85°C
Impedance:
75 ohms
Material:
halogen free
Version:
improved fire performance
VIDEOCOAX®
RG 11 LSZH
Temperature:
- 40°C to + 85°C
Impedance:
75 ohms
Material:
halogen free
Version:
improved fire performance
VIDEOCOAX®
RG 59 LSZH
Temperature:
- 40°C to + 85°C
Impedance:
75 ohms
Material:
halogen free
Version:
improved fire performance
VIDEOCOAX®
HD
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Approval:
RPC EN 50575
Use:
signaux vidéo HD
PRODUCTS
SPECIFICATIONS
TS CABLES®
11 VRtC classe A
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Approval:
RPC EN 50575
TS CABLES®
11 Z1RtC LSZH classe A
Temperature:
- 30°C to + 70°C
Impedance:
75 ohms
Material:
halogen free
TS CABLES®
11 PRtC classe A
Temperature:
- 30°C to + 70°C
Impedance:
75 ohms
Material:
PVC
Use:
external connection
TS CABLES®
11 PRtC AP classe A
Temperature:
- 30°C to + 70°C
Impedance:
75 ohms
Material:
PVC
Version:
with bearer
Use:
external connection
TS CABLES®
11 VAtC Classe A
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Approval:
RPC EN 50575
TS CABLES®
11 PAtC classe A
Temperature:
- 30°C to + 70°C
Impedance:
75 ohms
Material:
polyéthylène
Use:
external connection
COAXDESIGN®
17 VAtC classe B
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Version:
crystal, concrete-grey, alu colours
Use:
design high tech, art moderne, loft
TS CABLES®
17 VAtC classe B
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Approval:
RPC EN 50575
TS CABLES®
17 PAtC classe B
Temperature:
- 30°C to + 70°C
Impedance:
75 ohms
Material:
halogen free
Use:
external connection
TS CABLES®
17 VAtC classe A
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Approval:
RPC EN 50575
TS CABLES®
17 VAtCPH classe A
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Approval:
RPC EN 50575
TS CABLES®
17 PAtC classe A
Temperature:
- 30°C to + 70°C
Impedance:
75 ohms
Material:
halogen free
Use:
external connection
TS CABLES®
FP 1000® classe A
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
TS CABLES®
17 VRtC classe A
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Approval:
RPC EN 50575
TS CABLES®
17 PRtC classe A
Temperature:
- 30°C to + 70°C
Impedance:
75 ohms
Material:
halogen free
Use:
external connection
TS CABLES®
K1000® classe A
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Specific:
suitable for compression connectors
TS CABLES®
Connecteur CLIP F1000®
Composition:
coaxial K1000®
Connector:
FLIP F1000®
TS CABLES®
17 Z1AtC LSZH classe A
Temperature:
- 30°C to + 70°C
Impedance:
75 ohms
Material:
halogen free
TS CABLES®
KX 3B (RG 174/U)
Temperature:
- 30°C to + 80°C
Impedance:
50 ohms
Material:
PVC
TS CABLES®
KX 4 (RG 213/U)
Temperature:
- 30°C to + 80°C
Impedance:
50 ohms
Material:
PVC
TS CABLES®
KX 13 (RG 214/U)
Temperature:
- 30°C to + 80°C
Impedance:
50 ohms
Material:
PVC
TS CABLES®
KX 15 (RG 58C/U)
Temperature:
- 30°C to + 80°C
Impedance:
50 ohms
Material:
PVC
TS CABLES®
17 VAtC classe B Dca
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
halogen free
Approval:
RPC EN 50575 (Dca-s2, d2, a2)
PRODUCTS
SPECIFICATIONS
MULTI-VX®
BT
Rated voltage:
1000 V max
Version:
hybrid cable
Specific:
customised solution
MULTI-VX®
1024
Composition:
coaxial KX 6A and 2 conductors 0.75 mm²
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
extra flexible PVC
Approval:
RPC EN 50575
MULTI-VX®
1039
Composition:
coaxial and control cables
Temperature:
- 30°C to + 80°C
Rated voltage:
300 / 500 V
Impedance:
75 ohms
Material:
PVC
Use:
long distance
MULTI-VX®
1159
Composition:
coaxial KX 6A and 2 conductors 0.75 mm²
Temperature:
- 30°C to + 80°C
Rated voltage:
300 / 500 V
Impedance:
75 ohms
Material:
PVC
Approval:
RPC EN 50575
MULTI-VX®
1163
Composition:
coaxial and 2 conductors 0.75 mm²
Temperature:
- 30°C to + 80°C
Rated voltage:
450 / 750 V
Impedance:
75 ohms
Material:
PVC
Approval:
RPC EN 50575
MULTI-VX®
EI EG 2A1P9C
Composition:
2p0.40 + 1p0.60 + 9x0.22 mm²
Temperature:
- 30°C to + 80°C
Material:
PVC
Version:
hybrid cable

Electromechanical Applications

Low-voltage wires and cables for coil outlets on rotary machinery, Wires, cables and cable harnesses for hermetic group motors, Medium-voltage 1.1 to 15 kV flexible cables and Braided sleevings in Classes B, F, H, C

The OMERIN Group has made a name for itself in the electromechanical sector (rotary machinery, alternators, generators, hermetic groups, etc.). Our cable ranges SILICABLE® (silicone insulated wires and cables with or without reinforcing braid, Class H), VARPREN® (Varpren® elastomer insulated wires and cables, Class B), SILIFLON® (fluoropolymer-insulated wires and cables with or without reinforcing braid, Class F), SILICOUL® (flexible medium-voltage cables, Class H) and SILIGAINE® (braided insulated sleevings in glass yarn or polyester, Classes B, F, H, C) offer an excellent response to the vast majority of special market needs. These products offer improved mechanical strength and high-temperature resistance. Our products comply with the main international standards and certifications: UL, CSA, Lloyd’s register to guarantee top-notch reliability and quality.

PRODUCTS
SPECIFICATIONS
VARPREN®
125
Temperature:
- 50°C to + 125°C
Rated voltage:
450/750 V, 600/1000 V
Material:
Varpren®
VARPREN®
Style 3266
Temperature:
- 30°C to + 125°C
Rated voltage:
300 V
Material:
Varpren®
Approval:
UL
VARPREN®
Style 3173
Temperature:
- 30°C to + 125°C
Rated voltage:
600 V
Material:
Varpren®
Approval:
UL
VARPREN®
Style 3271
Temperature:
- 30°C to + 125°C
Rated voltage:
600 V
Material:
Varpren®
Approval:
UL
PRODUCTS
SPECIFICATIONS
VARPREN®
ST
Temperature:
- 40°C to + 155°C
Rated voltage:
600/1000 V
Material:
Varpren®
VARPREN®
F
Temperature:
- 40°C to + 155°C
Rated voltage:
600/1000 V
Material:
Varpren®
VARPREN®
155
Temperature:
- 50°C to + 155°C
Rated voltage:
450/750 V, 600/1000 V
Material:
Varpren®
VARPREN®
Style 3398
Temperature:
- 10°C to + 150°C (- 55°C cf. PV)
Rated voltage:
300 V
Material:
Varpren®
Approval:
UL
VARPREN®
Style 3289
Temperature:
- 10°C to + 150°C (- 55°C cf. PV)
Rated voltage:
600 V
Material:
Varpren®
Approval:
UL
VARPREN®
Style 3321
Temperature:
- 10°C to + 150°C (- 55°C cf. PV)
Rated voltage:
600 V
Material:
Varpren®
Approval:
UL
VARPREN®
MVA
Temperature:
- 30°C to + 150°C
Rated voltage:
450/750 V
Material:
Varpren®
VARPREN®
MVA-C-VA
Temperature:
- 30°C to + 150°C
Rated voltage:
450/750 V
Material:
Varpren®
VARPREN®
Style 30097
Temperature:
- 10°C to + 150°C (- 55°C cf. PV)
Rated voltage:
750 V
Material:
Varpren®
Approval:
UL
SILIFLON®
ETFE, EETFE
Temperature:
- 90°C to + 150°C
Rated voltage:
450/750 V
Material:
fluoropolymer
SILIFLON®
Style 10935
Temperature:
- 60°C to + 150°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 11881
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1827
Temperature:
- 90°C to + 150°C
Rated voltage:
125 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10125
Temperature:
- 90°C to + 150°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1828
Temperature:
- 90°C to + 150°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1643
Temperature:
- 90°C to + 150°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1333 VW-1
Temperature:
- 90°C to + 150°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10210
Temperature:
- 90°C to + 150°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10126 VW-1
Temperature:
- 90°C to + 150°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1644
Temperature:
- 90°C to + 150°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1331
Temperature:
- 90°C to + 150°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10358
Temperature:
- 90°C to + 150°C
Rated voltage:
1000 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 11945
Temperature:
- 90°C to + 150°C
Rated voltage:
750 V
Material:
fluoropolymer
Approval:
UL
PRODUCTS
SPECIFICATIONS
SILICABLE®
CS, ECS
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V, 600/1000 V
Material:
silicone
Core:
flexible
SILICABLE®
RCS, RECS
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V
Material:
silicone
Core:
rigid
SILICABLE®
SIR-IDC
Temperature:
- 60°C to + 180°C
Rated voltage:
300/300 V
Material:
silicone
Approval:
VDE
SILICABLE®
CS-ES, ECS-ES
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V, 600/1000 V
Material:
silicone
Core:
extra flexible
SILICABLE®
CSC, ECSC
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V
Material:
silicone
SILICABLE®
CS-THT, ECS-THT
Temperature:
- 60°C to + 250°C
Rated voltage:
300/500 V
Material:
silicone
Core:
flexible
SILICABLE®
RCS-THT, RECS-THT
Temperature:
- 60°C to + 250°C
Rated voltage:
300/500 V
Material:
silicone
Core:
rigid
SILICABLE®
Style 3367
Temperature:
- 60°C to + 200°C
Rated voltage:
300 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3135
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3135 VW-1
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3139
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3143
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3268
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3512
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3512 VW-1
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3530
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3755
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3572
Temperature:
- 60°C to + 200°C
Rated voltage:
1000 V (cUL 600 V)
Material:
silicone
Approval:
UL
SILICABLE®
Style 3644
Temperature:
- 60°C to + 200°C
Rated voltage:
1000 V (cUL 600 V)
Material:
silicone
Approval:
UL
SILICABLE®
CS-HRD, ESC-HRD
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V
Material:
silicone
Version:
improved mechanical strength
SILICABLE®
CS-FRNC
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V
Material:
silicone
SILICABLE®
Style 30096
Temperature:
- 60°C to + 200°C
Rated voltage:
750 V
Material:
silicone
Approval:
UL
SILICABLE®
VMC-ECS
Temperature:
- 60°C to + 180°C
Rated voltage:
600/1000 V
Material:
silicone with reinforcing braid
SILICABLE®
PMC-ECS
Temperature:
- 60°C to + 180°C
Rated voltage:
600/1000 V
Material:
silicone with reinforcing braid
SILICABLE®
PMCBEC-ECS
Temperature:
- 60°C to + 180°C
Rated voltage:
600/1000 V
Material:
silicone with reinforcing braid
Core:
flexible
Shielding:
tin-plated copper braid
SILICABLE®
ECSBECSP
Temperature:
- 60°C to + 180°C
Rated voltage:
600/1000 V
Material:
silicone with reinforcing braid
Core:
flexible
Shielding:
tin-plated copper braid
SILIFLON®
Style 10109
Temperature:
- 90°C to + 200°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10969
Temperature:
- 90°C to + 200°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1900
Temperature:
- 90°C to + 200°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1332 VW-1
Temperature:
- 90°C to + 200°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1332 VW-1
Temperature:
- 90°C to + 200°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10588
Temperature:
- 90°C to + 200°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1901
Temperature:
- 90°C to + 200°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1330 VW-1
Temperature:
- 90°C to + 200°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1930
Temperature:
- 90°C to + 200°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10203
Temperature:
- 90°C to + 200°C
Rated voltage:
1000 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10048
Temperature:
- 90°C to + 200°C
Rated voltage:
1000 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1933
Temperature:
- 90°C to + 250°C
Rated voltage:
VNS
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1882
Temperature:
- 90°C to + 250°C
Rated voltage:
150 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10486
Temperature:
- 90°C to + 250°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10410
Temperature:
- 90°C to + 250°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1726
Temperature:
- 90°C to + 250°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10297
Temperature:
- 90°C to + 250°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10362
Temperature:
- 90°C to + 250°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1727 VW-1
Temperature:
- 90°C to + 250°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10300
Temperature:
- 90°C to + 250°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10371
Temperature:
- 90°C to + 250°C
Rated voltage:
1000 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
M6-E6
Temperature:
- 90°C to + 205°C
Rated voltage:
300/500 V
Material:
fluoropolymer
SILIFLON®
M6BE-E6
Temperature:
- 90°C to + 205°C
Rated voltage:
300/500 V
Material:
fluoropolymer
Shielding:
tin-plated copper braid
PRODUCTS
SPECIFICATIONS
SILICABLE®
GHR
Temperature:
- 30°C to + 125°C
Rated voltage:
600 V
Material:
composites
SILICABLE®
Style 5170
Temperature:
- 30°C to + 125°C
Rated voltage:
600 V
Material:
composites
Approval:
UL
PRODUCTS
SPECIFICATIONS
SILICOUL®
1.1 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
Lloyd's register & BV
SILICOUL®
3.7 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
Lloyd's register
SILICOUL®
6.6 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
Lloyd's register
SILICOUL®
13.8 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
Lloyd's register
SILICOUL®
Style 3661
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
UL
SILICOUL®
Style 3662
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
UL
SILICOUL®
Style 3663
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
UL
SILICOUL®
Style 3664
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
UL
SILICOUL®
ALU FLEX 1.1 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Version:
with aluminium core
SILICOUL®
ALU FLEX 3.7 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Version:
with aluminium core
SILICOUL®
ALU FLEX 6.6 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Version:
with aluminium core
SILICOUL®
ALU FLEX 13.8 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Version:
with aluminium core
SILICOUL®
SCR 1.1 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Shielding:
tin-plated copper braid
SILICOUL®
SCR 3.7 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Shielding:
tin-plated copper braid
SILICOUL®
SCR 6.6 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Shielding:
tin-plated copper braid
SILICOUL®
SCR 13.8 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Shielding:
tin-plated copper braid
SILICOUL®
DI 1.1 KV
Temperature:
- 60°C to + 180°C
Material:
silicone
Version:
double insulation
SILICOUL®
DI 3.7 KV
Temperature:
- 60°C to + 180°C
Material:
silicone
Version:
double insulation
SILICOUL®
DI 6.6 KV
Temperature:
- 60°C to + 180°C
Material:
silicone
Version:
double insulation
SILICOUL®
DI 13.8 KV
Temperature:
- 60°C to + 180°C
Material:
silicone
Version:
double insulation
SILICOUL®
DI Style 3661 - 1.1 KV
Temperature:
- 60°C to + 180°C
Material:
silicone
Version:
double insulation
Approval:
UL
SILICOUL®
DI Style 3662 - 4.2 KV
Temperature:
- 60°C to + 180°C
Material:
silicone
Version:
double insulation
Approval:
UL
SILICOUL®
DI Style 3663 - 7.2 KV
Temperature:
- 60°C to + 180°C
Material:
silicone
Version:
double insulation
Approval:
UL
SILICOUL®
DI Style 3664 - 15 KV
Temperature:
- 60°C to + 180°C
Material:
silicone
Version:
double insulation
Approval:
UL
SILICOUL®
ST PUR 1.1 KV
Temperature:
- 40°C to + 150°C
Material:
silicone / Polyurethane
Version:
double insulation
Resistance:
hydrocarbons
SILICOUL®
ST PUR 3.7 KV
Temperature:
- 40°C to + 150°C
Material:
silicone / Polyurethane
Version:
double insulation
Resistance:
hydrocarbons
SILICOUL®
ST PUR 6.6 KV
Temperature:
- 40°C to + 150°C
Material:
silicone / Polyurethane
Version:
double insulation
Resistance:
hydrocarbons
SILICOUL®
ST PUR 13.8 KV
Temperature:
- 40°C to + 150°C
Material:
silicone / Polyurethane
Version:
double insulation
Resistance:
hydrocarbons
SILICOUL®
SCR PUR 1.1 KV
Temperature:
- 40°C to + 150°C
Material:
silicone with reinforcing braid / PU
Shielding:
tin-plated copper braid
Resistance:
hydrocarbons
SILICOUL®
SCR PUR 3.7 KV
Temperature:
- 40°C to + 150°C
Material:
silicone with reinforcing braid / PU
Shielding:
tin-plated copper braid
Resistance:
hydrocarbons
SILICOUL®
SCR PUR 6.6 KV
Temperature:
- 40°C to + 150°C
Material:
silicone with reinforcing braid / PU
Shielding:
tin-plated copper braid
Resistance:
hydrocarbons
SILICOUL®
SCR PUR 13.8 KV
Temperature:
- 40°C to + 150°C
Material:
silicone with reinforcing braid / PU
Shielding:
tin-plated copper braid
Resistance:
hydrocarbons
PRODUCTS
SPECIFICATIONS
SILIGAINE®
15C1.5
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
1.5 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C2
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
2.5 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C3
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 3 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C3-UV
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 3 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C4
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 4 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C4.d
Temperature:
- 60°C to + 200°C, Class H & C
Dielectric strength:
> 4 kV (dry)
Material:
fiberglass (double insulation)
Version:
abrasion resistance
SILIGAINE®
15C5
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 5 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C5-E EXTENSIBLE
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 5 kV (dry)
Material:
fiberglass with silicone coating
Version:
expandable
SILIGAINE®
15C7 GRADE A UL
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 7 kV (dry)
Material:
fiberglass with silicone coating
Version:
expandable
SILIGAINE®
15C10
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 10 kV (dry)
Material:
fiberglass with silicone coating
PRODUCTS
SPECIFICATIONS
SILIGAINE®
13F1
Temperature:
- 30°C to + 155°C, Class F
Dielectric strength:
> 1 kV (dry)
Material:
fiberglass with PU coating
SILIGAINE®
13F3
Temperature:
- 30°C to + 155°C, Class F
Dielectric strength:
3 kV (dry, central value)
Material:
fiberglass with PU coating
SILIGAINE®
13F4
Temperature:
- 30°C to + 155°C, Class F
Dielectric strength:
> 4 kV (dry)
Material:
fiberglass with PU coating
SILIGAINE®
16F2
Temperature:
- 30°C to + 155°C, Class F
Dielectric strength:
1.8 kV (dry, central value)
Material:
fiberglass with acrylic coating
SILIGAINE®
16F3
Temperature:
- 30°C to + 155°C, Class F
Dielectric strength:
3.3 kV (dry, central value)
Material:
fiberglass with acrylic coating
SILIGAINE®
16F7 UL
Temperature:
- 30°C to + 155°C, Class F
Dielectric strength:
7 kV (dry, central value)
Material:
fiberglass with acrylic coating
Approval:
UL

Household Appliances

Low-voltage wires and cables, Ignition wires, Braided insulated sleevings, Oven door seals UL, CSA, HAR and VDE

The OMERIN Group is a major player in the Household Appliance sector. Our comprehensive range of products: low-voltage wires and cables (thermoplastic-insulated PLASTHERM®, fluoropolymer-insulated SILIFLON®, silicone elastomer and SILICABLE® composite insulation), ignition wires (SILICABLE® silicone elastomer and SILIFLON® fluoropolymer), SILIGAINE® braided insulated sleeving and VEROX® pyrolysis oven door seals enable us to offer solutions for almost any application. Our products comply with the main international standards and certifications: UL, CSA, HAR, VDE to guarantee top-notch reliability and quality. In addition to this offer, the OMERIN Group manufactures food-product tubes and flexible heating elements.

PRODUCTS
SPECIFICATIONS
PLASTHERM®
Y2, EY2
Temperature:
- 30°C to + 105°C
Rated voltage:
300/500 V, 450/750 V
Material:
thermoplastic PVC
PLASTHERM®
Style 1007
Temperature:
- 30°C to + 80°C
Rated voltage:
300 V
Material:
thermoplastic PVC
Approval:
UL
PLASTHERM®
Style 1497
Temperature:
- 30°C to + 80°C
Rated voltage:
300 V
Material:
thermoplastic PVC
Approval:
UL
PLASTHERM®
Style 1581
Temperature:
- 30°C to + 80°C
Rated voltage:
300 V
Material:
thermoplastic PVC
Approval:
UL
PLASTHERM®
Style 10053
Temperature:
- 30°C to + 80°C
Rated voltage:
300 V
Material:
thermoplastic PVC
Approval:
UL
PLASTHERM®
Style 1011
Temperature:
- 30°C to + 80°C
Rated voltage:
600 V
Material:
thermoplastic PVC
Approval:
UL
PLASTHERM®
Style 10381
Temperature:
- 30°C to + 80°C
Rated voltage:
600 V
Material:
thermoplastic PVC
Approval:
UL
PLASTHERM®
Style 1030
Temperature:
- 30°C to + 80°C
Rated voltage:
1000 V
Material:
thermoplastic PVC
Approval:
UL
PLASTHERM®
Style 1569 VW-1
Temperature:
- 30°C to + 105°C
Rated voltage:
300 V
Material:
thermoplastic PVC
Approval:
UL
PLASTHERM®
Style 10198
Temperature:
- 30°C to + 105°C
Rated voltage:
300 V
Material:
thermoplastic PVC
Approval:
UL
PLASTHERM®
Style 1896
Temperature:
- 30°C to + 105°C
Rated voltage:
300 V
Material:
thermoplastic PVC
Approval:
UL
PLASTHERM®
Style 10012
Temperature:
- 30°C to + 105°C
Rated voltage:
600 V
Material:
thermoplastic PVC
Approval:
UL
PLASTHERM®
Style 1015
Temperature:
- 30°C to + 105°C
Rated voltage:
600 V
Material:
thermoplastic PVC
Approval:
UL
PLASTHERM®
Style 1283
Temperature:
- 30°C to + 105°C
Rated voltage:
600 V
Material:
thermoplastic PVC
Approval:
UL
PLASTHERM®
Style 1897
Temperature:
- 30°C to + 105°C
Rated voltage:
600 V
Material:
thermoplastic PVC
Approval:
UL
PLASTHERM®
Style 10914
Temperature:
- 30°C to + 105°C
Rated voltage:
1000 V
Material:
thermoplastic PVC
Approval:
UL
PLASTHERM®
Style 10271
Temperature:
- 30°C to + 105°C
Rated voltage:
1000 V
Material:
thermoplastic PVC
Approval:
UL
PLASTHERM®
Style 10269
Temperature:
- 30°C to + 105°C
Rated voltage:
1000 V
Material:
thermoplastic PVC
Approval:
UL
PLASTHERM®
Style 1015-HAR
Temperature:
- 30°C to + 105°C
Rated voltage:
600 V (cUL 1000 V)
Material:
thermoplastic PVC
Approval:
UL
PLASTHERM®
Style 20199
Temperature:
- 30°C to + 105°C
Rated voltage:
300 V
Material:
thermoplastic PVC
Approval:
UL
PLASTHERM®
Style 10900
Temperature:
- 20°C to + 90°C
Rated voltage:
600 V
Material:
HFFR
Approval:
UL
PLASTHERM®
PHF2, PHF2E, PHF2R
Temperature:
- 40°C to + 105°C
Rated voltage:
600/1000 V
Material:
HFFR
PLASTHERM®
PHF2E IRD
Temperature:
- 40°C to + 105°C
Rated voltage:
250 V
Material:
HFFR
PLASTHERM®
PHFLEX
Temperature:
- 35°C to + 90°C
Rated voltage:
450/750 V
Material:
HFFR
Core:
extra flexible
PLASTHERM®
HP-U
Temperature:
- 20°C to + 80°C
Rated voltage:
400 V
Material:
thermoplastic PVC
PLASTHERM®
HP-M
Temperature:
- 20°C to + 80°C
Rated voltage:
400 V
Material:
thermoplastic PVC
PLASTHERM®
HP-M-HT
Temperature:
- 20°C to + 105°C
Rated voltage:
400 V
Material:
thermoplastic PVC
PRODUCTS
SPECIFICATIONS
SILICABLE®
CS, ECS
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V, 600/1000 V
Material:
silicone
Core:
flexible
SILICABLE®
RCS, RECS
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V
Material:
silicone
Core:
rigid
SILICABLE®
H05S-K, H05S-U
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V
Material:
silicone
Approval:
<HAR>
SILICABLE®
H05SS-K
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V
Material:
silicone
Approval:
<HAR>
SILICABLE®
SIF, SIR, SIE
Temperature:
- 60°C to + 180°C
Rated voltage:
300/300 V
Material:
silicone
Approval:
VDE
SILICABLE®
N2GFAF, N2GFA
Temperature:
- 60°C to + 180°C
Rated voltage:
300/300 V
Material:
silicone
Approval:
VDE
SILICABLE®
SIR-IDC
Temperature:
- 60°C to + 180°C
Rated voltage:
300/300 V
Material:
silicone
Approval:
VDE
SILICABLE®
CS-ES, ECS-ES
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V, 600/1000 V
Material:
silicone
Core:
extra flexible
SILICABLE®
CSC, ECSC
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V
Material:
silicone
SILICABLE®
ECSC-VDE, CNCSC-VDE
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V
Material:
silicone
SILICABLE®
CS-THT, ECS-THT
Temperature:
- 60°C to + 250°C
Rated voltage:
300/500 V
Material:
silicone
Core:
flexible
SILICABLE®
RCS-THT, RECS-THT
Temperature:
- 60°C to + 250°C
Rated voltage:
300/500 V
Material:
silicone
Core:
rigid
SILICABLE®
Style 3232
Temperature:
- 60°C to + 105°C
Rated voltage:
300 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3243
Temperature:
- 60°C to + 105°C
Rated voltage:
300 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3171
Temperature:
- 60°C to + 105°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3099
Temperature:
- 60°C to + 150°C
Rated voltage:
300 V (cUL 600 V)
Material:
silicone
Approval:
UL
SILICABLE®
Style 3132
Temperature:
- 60°C to + 150°C
Rated voltage:
300 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3132 VW-1
Temperature:
- 60°C to + 150°C
Rated voltage:
300 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3123
Temperature:
- 60°C to + 150°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3133
Temperature:
- 60°C to + 150°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3134
Temperature:
- 60°C to + 150°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3134 VW-1
Temperature:
- 60°C to + 150°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3137
Temperature:
- 60°C to + 150°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3138
Temperature:
- 60°C to + 150°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3529
Temperature:
- 60°C to + 150°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3536
Temperature:
- 60°C to + 150°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3580
Temperature:
- 60°C to + 150°C
Rated voltage:
1000 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3367
Temperature:
- 60°C to + 200°C
Rated voltage:
300 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3135
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3135 VW-1
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3139
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3143
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3268
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3512
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3512 VW-1
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3530
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3755
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3572
Temperature:
- 60°C to + 200°C
Rated voltage:
1000 V (cUL 600 V)
Material:
silicone
Approval:
UL
SILICABLE®
Style 3644
Temperature:
- 60°C to + 200°C
Rated voltage:
1000 V (cUL 600 V)
Material:
silicone
Approval:
UL
SILICABLE®
CS-HRD, ESC-HRD
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V
Material:
silicone
Version:
improved mechanical strength
SILICABLE®
CS-FRNC
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V
Material:
silicone
SILICABLE®
M-CS-TBT
Temperature:
- 60°C to + 180°C
Rated voltage:
300 V
Material:
silicone
SILICABLE®
SIZ-VDE
Temperature:
- 60°C to + 180°C
Rated voltage:
300 V
Material:
silicone
SILICABLE®
Style 30096
Temperature:
- 60°C to + 200°C
Rated voltage:
750 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 3858
Temperature:
- 60°C to + 150°C
Rated voltage:
3000 V
Material:
silicone
Core:
Extra-flexible
Approval:
UL
PRODUCTS
SPECIFICATIONS
SILICABLE®
CSV, ECSV
Temperature:
- 60°C to + 220°C
Rated voltage:
300/500 V, 600/1000 V
Material:
silicone with reinforcing braid
Core:
flexible
SILICABLE®
CSVRI, ECSVRI
Temperature:
- 60°C to + 220°C
Rated voltage:
450/750 V
Material:
silicone with reinforcing braid
Core:
flexible
Version:
designed for stripping on automatic machines
SILICABLE®
H05SJ-K
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V
Material:
silicone with reinforcing braid
Core:
flexible
Approval:
<HAR>
SILICABLE®
H05SJ-U
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V
Material:
silicone with reinforcing braid
Core:
rigid
Approval:
<HAR>
SILICABLE®
Style 3068
Temperature:
- 60°C to + 150°C
Rated voltage:
300 V
Material:
silicone with reinforcing braid
Approval:
UL
SILICABLE®
Style 3132 with braid
Temperature:
- 60°C to + 150°C
Rated voltage:
300 V
Material:
silicone with reinforcing braid
Approval:
UL
SILICABLE®
Style 3069
Temperature:
- 60°C to + 150°C
Rated voltage:
600 V
Material:
silicone with reinforcing braid
Approval:
UL
SILICABLE®
Style 3070
Temperature:
- 60°C to + 150°C
Rated voltage:
600 V
Material:
silicone with reinforcing braid
Approval:
UL
SILICABLE®
Style 3535
Temperature:
- 60°C to + 150°C
Rated voltage:
600 V
Material:
silicone with reinforcing braid
Approval:
UL
SILICABLE®
Style 3122
Temperature:
- 60°C to + 200°C
Rated voltage:
300 V
Material:
silicone with reinforcing braid
Approval:
UL
SILICABLE®
Style 3122 VW-1
Temperature:
- 60°C to + 200°C
Rated voltage:
300 V
Material:
silicone with reinforcing braid
Approval:
UL
SILICABLE®
Style 3071
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone with reinforcing braid
Approval:
UL
SILICABLE®
Style 3513
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone with reinforcing braid
Approval:
UL
SILICABLE®
Style 3513 VW-1
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone with reinforcing braid
Approval:
UL
SILICABLE®
Style 3645
Temperature:
- 60°C to + 200°C
Rated voltage:
1000 V (cUL 600 V)
Material:
silicone with reinforcing braid
Approval:
UL
SILICABLE®
CSVCS, ECSVCS
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V
Material:
silicone with reinforcing braid
Version:
double insulating layer
SILICABLE®
CSP, ECSP
Temperature:
- 60°C to + 180°C
Rated voltage:
450/750 V, 600/1000 V
Material:
silicone with reinforcing braid
SILICABLE®
ECSPRI
Temperature:
- 60°C to + 180°C
Rated voltage:
600/1000 V
Material:
silicone with reinforcing braid
SILICABLE®
Style 3779
Temperature:
- 60°C to + 180°C
Rated voltage:
600 V
Material:
silicone with reinforcing braid
Approval:
UL
SILICABLE®
Style 30133
Temperature:
- 60°C to + 150°C
Rated voltage:
3000 V
Material:
silicone with reinforcing braid
Core:
Extra-flexible
Approval:
UL
PRODUCTS
SPECIFICATIONS
SILIFLON®
ETFE, EETFE
Temperature:
- 90°C to + 150°C
Rated voltage:
450/750 V
Material:
fluoropolymer
SILIFLON®
7YA
Temperature:
- 90°C to + 130°C
Rated voltage:
450/750 V, 300/500 V
Material:
fluoropolymer
Core:
flexible
SILIFLON®
7Y
Temperature:
- 90°C to + 135°C
Rated voltage:
375V to 900V (depending on thickness of insulation)
Material:
fluoropolymer
Core:
rigid
SILIFLON®
LI7Y
Temperature:
- 90°C to + 135°C
Rated voltage:
375V to 900V (depending on thickness of insulation)
Material:
fluoropolymer
Core:
concentric
SILIFLON®
FEP, EFEP
Temperature:
- 90°C to + 205°C
Rated voltage:
450/750 V
Material:
fluoropolymer
SILIFLON®
6YS
Temperature:
- 90°C to + 130°C
Rated voltage:
450/750 V, 300/500 V
Material:
fluoropolymer
Material:
flexible
SILIFLON®
6Y6YS, E6Y6YS
Temperature:
- 90°C to + 180°C
Rated voltage:
300/500 V
Material:
fluoropolymer
SILIFLON®
PFA, EPFA
Temperature:
- 90°C to + 260°C
Rated voltage:
450/750 V
Material:
fluoropolymer
SILIFLON®
51YS
Temperature:
- 90°C to + 250°C
Rated voltage:
300/500 V
Material:
fluoropolymer
Core:
flexible
SILIFLON®
RETFE, RFEP, RPFA
Temperature:
- 90°C to + 260°C
Rated voltage:
450/750 V
Material:
fluoropolymer
Core:
rigid
SILIFLON®
Style 1513
Temperature:
- 90°C to + 105°C
Rated voltage:
VNS
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1227
Temperature:
- 90°C to + 105°C
Rated voltage:
VNS
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1508
Temperature:
- 90°C to + 105°C
Rated voltage:
30 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10935
Temperature:
- 60°C to + 150°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 11881
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1827
Temperature:
- 90°C to + 150°C
Rated voltage:
125 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10125
Temperature:
- 90°C to + 150°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1828
Temperature:
- 90°C to + 150°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1643
Temperature:
- 90°C to + 150°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1333 VW-1
Temperature:
- 90°C to + 150°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10210
Temperature:
- 90°C to + 150°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10126 VW-1
Temperature:
- 90°C to + 150°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1644
Temperature:
- 90°C to + 150°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1331
Temperature:
- 90°C to + 150°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10358
Temperature:
- 90°C to + 150°C
Rated voltage:
1000 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10358
Temperature:
- 90°C to + 200°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10969
Temperature:
- 90°C to + 200°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1900
Temperature:
- 90°C to + 200°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1332 VW-1
Temperature:
- 90°C to + 200°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10086
Temperature:
- 90°C to + 200°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10588
Temperature:
- 90°C to + 200°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1901
Temperature:
- 90°C to + 200°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1330 VW-1
Temperature:
- 90°C to + 200°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1930
Temperature:
- 90°C to + 200°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10203
Temperature:
- 90°C to + 200°C
Rated voltage:
1000 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10048
Temperature:
- 90°C to + 200°C
Rated voltage:
1000 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1933
Temperature:
- 90°C to + 250°C
Rated voltage:
VNS
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1882
Temperature:
- 90°C to + 250°C
Rated voltage:
150 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10486
Temperature:
- 90°C to + 250°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10410
Temperature:
- 90°C to + 250°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1726
Temperature:
- 90°C to + 250°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10297
Temperature:
- 90°C to + 250°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10362
Temperature:
- 90°C to + 250°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 1727 VW-1
Temperature:
- 90°C to + 250°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10300
Temperature:
- 90°C to + 250°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 10371
Temperature:
- 90°C to + 250°C
Rated voltage:
1000 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
CN5YS, A5YS
Temperature:
- 90°C to + 250°C
Rated voltage:
300/500 V
Material:
fluoropolymer
SILIFLON®
Style 10506
Temperature:
- 90°C to + 250°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
HT
Temperature:
- 90°C to + 260°C
Rated voltage:
12 to 30 kV
Material:
fluoropolymer
SILIFLON®
Style 11945
Temperature:
- 90°C to + 150°C
Rated voltage:
750 V
Material:
fluoropolymer
Approval:
UL
PRODUCTS
SPECIFICATIONS
VARPREN®
ST
Temperature:
- 40°C to + 155°C
Rated voltage:
600/1000 V
Material:
Varpren®
VARPREN®
F
Temperature:
- 40°C to + 155°C
Rated voltage:
600/1000 V
Material:
Varpren®
VARPREN®
H05Z-K
Temperature:
- 15°C to + 90°C
Rated voltage:
300/500 V
Material:
Varpren®
Version:
halogen free
Approval:
<HAR>
VARPREN®
H07Z-K
Temperature:
- 15°C to + 90°C
Rated voltage:
450/750 V
Material:
Varpren®
Version:
halogen free
Approval:
<HAR>
VARPREN®
H05G-K
Temperature:
- 15°C to + 110°C
Rated voltage:
300/500 V
Material:
Varpren®
Version:
halogen free
Approval:
<HAR>
VARPREN®
H07G-K
Temperature:
- 15°C to + 110°C
Rated voltage:
450/750 V
Material:
Varpren®
Version:
halogen free
Approval:
<HAR>
VARPREN®
125
Temperature:
- 50°C to + 125°C
Rated voltage:
450/750 V, 600/1000 V
Material:
Varpren®
VARPREN®
155
Temperature:
- 50°C to + 155°C
Rated voltage:
450/750 V, 600/1000 V
Material:
Varpren®
VARPREN®
Style 3266
Temperature:
- 30°C to + 125°C
Rated voltage:
300 V
Material:
Varpren®
Approval:
UL
VARPREN®
Style 3173
Temperature:
- 30°C to + 125°C
Rated voltage:
600 V
Material:
Varpren®
Approval:
UL
VARPREN®
Style 3271
Temperature:
- 30°C to + 125°C
Rated voltage:
600 V
Material:
Varpren®
Approval:
UL
VARPREN®
Style 3398
Temperature:
- 10°C to + 150°C (- 55°C cf. PV)
Rated voltage:
300 V
Material:
Varpren®
Approval:
UL
VARPREN®
Style 3289
Temperature:
- 10°C to + 150°C (- 55°C cf. PV)
Rated voltage:
600 V
Material:
Varpren®
Approval:
UL
VARPREN®
Style 3321
Temperature:
- 10°C to + 150°C (- 55°C cf. PV)
Rated voltage:
600 V
Material:
Varpren®
Approval:
UL
VARPREN®
Style 3781
Temperature:
- 30°C to + 105°C
Rated voltage:
1000 V (UL, cUL)
Material:
Varpren®
Approval:
UL
VARPREN®
FLR
Temperature:
- 40°C to + 150°C
Rated voltage:
60 V
Material:
Varpren®
VARPREN®
Style 30097
Temperature:
- 10°C to + 150°C (- 55°C cf. PV)
Rated voltage:
750 V
Material:
Varpren®
Approval:
UL
PRODUCTS
SPECIFICATIONS
PROFIPLAST®
CABLETTE
Material:
stranded bare copper core
Resistance:
hydrocarbons
PROFIPLAST®
H05V-U
Temperature:
- 5°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Approval:
RPC EN 50575, <HAR>
PROFIPLAST®
H05V2-U
Temperature:
- 5°C to + 90°C
Rated voltage:
300/500 V
Material:
PVC
Approval:
<HAR>
PROFIPLAST®
H07V-U
Temperature:
- 5°C to + 70°C
Rated voltage:
450/750 V
Material:
PVC
Approval:
RPC EN 50575, <HAR>
PROFIPLAST®
H07V2-U
Temperature:
- 5°C to + 90°C
Rated voltage:
450/750 V
Material:
PVC
Approval:
<HAR>
PROFIPLAST®
H07V-R
Temperature:
- 5°C to + 70°C
Rated voltage:
450/750 V
Material:
PVC
Approval:
RPC EN 50575, <HAR>
PROFIPLAST®
07V2-R
Temperature:
- 5°C to + 90°C
Rated voltage:
450/750 V
Material:
PVC
PROFIPLAST®
H05V-K
Temperature:
- 5°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Approval:
RPC EN 50575, <HAR>
PROFIPLAST®
H05V2-K
Temperature:
- 5°C to + 90°C
Rated voltage:
300/500 V
Material:
PVC
Approval:
<HAR>
PROFIPLAST®
H07V-K
Temperature:
- 5°C to + 70°C
Rated voltage:
450/750 V
Material:
PVC
Approval:
RPC EN 50575, <HAR>
PROFIPLAST®
H07V2-K
Temperature:
- 5°C to + 90°C
Rated voltage:
450/750 V
Material:
PVC
Approval:
RPC EN 50575, <HAR>
PROFIPLAST®
SV-HT 105
Temperature:
- 25°C to + 105°C
Rated voltage:
300/500 V, 450/750 V
Material:
PVC
PROFIPLAST®
SV-THT 125
Temperature:
- 25°C to + 105°C
Rated voltage:
300/500 V, 450/750 V
Material:
PVC
PROFIPLAST®
05Z1-K
Temperature:
- 5°C to + 70°C
Rated voltage:
300/500 V
Material:
halogen free
PROFIPLAST®
07Z1-K
Temperature:
- 5°C to + 70°C
Rated voltage:
450/750 V
Material:
halogen free
PROFIPLAST®
FR-N07V-AR
Temperature:
- 5°C to + 70°C
Rated voltage:
450/750 V
Material:
PVC
Core:
aluminium (16, 25, 35 mm²)
Approval:
RPC EN 50575, NF USE
PROFIPLAST®
TWISTE
Temperature:
- 5°C to + 70°C
Rated voltage:
450/750 V
Material:
PVC
Version:
twisted
PROFIPLAST®
FR-N05VV-U
Temperature:
- 5°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Approval:
NF USE
PROFIPLAST®
H03VV-F
Temperature:
- 5°C to + 60°C
Rated voltage:
300/300 V
Material:
PVC
Approval:
<HAR>
PROFIPLAST®
H03V2V2-F
Temperature:
- 5°C to + 90°C
Rated voltage:
300/300 V
Material:
PVC
PROFIPLAST®
H05VV-F
Temperature:
- 5°C to + 60°C
Rated voltage:
300/500 V
Material:
PVC
Approval:
<HAR>
PROFIPLAST®
H05V2V2-F
Temperature:
- 5°C to + 90°C
Rated voltage:
300/500 V
Material:
PVC
Approval:
<HAR>
PROFIPLAST®
CSR
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
PROFIPLAST®
CSR-HT
Temperature:
- 25°C to + 105°C
Rated voltage:
600/1000 V
Material:
PVC
PROFIPLAST®
CSR LSZH
Temperature:
- 20°C to + 70°C
Rated voltage:
300/500 V
Material:
halogen free
PROFIPLAST®
CSR BPA
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Version:
sreened
PROFIPLAST®
CSR BE
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Shielding:
tin-plated copper braid
PROFIPLAST®
03Z1Z1-F
Temperature:
- 5°C to + 60°C
Rated voltage:
300/300 V
Material:
halogen free
PROFIPLAST®
05Z1Z1-F
Temperature:
- 5°C to + 60°C
Rated voltage:
300/500 V
Material:
halogen free
PROFIPLAST®
H03VVH2-F
Temperature:
- 5°C to + 60°C
Rated voltage:
300/300 V
Material:
PVC
Version:
flat cable
Approval:
<HAR>
LUMIPLAST®
03VH-H
Temperature:
- 5°C to + 60°C
Rated voltage:
300/300 V
Material:
PVC
Version:
2-conductor
PROFIPLAST®
PBS-R
Temperature:
- 25°C to + 70°C
Rated voltage:
450/750 V
Material:
atoxic Profiprene
Approval:
AD8 (250 m), ACS
Use:
fresh water
PROFIPLAST®
PBS-R BE
Temperature:
- 25°C to + 70°C
Rated voltage:
450/750 V
Material:
atoxic Profiprene
Shielding:
tin-plated copper braid
Approval:
AD8 (250 m), ACS
Use:
fresh water
PROFIPLAST®
PBS-P
Temperature:
- 25°C to + 70°C
Rated voltage:
450/750 V
Material:
atoxic Profiprene
Version:
flat cable
Approval:
AD8 (250 m), ACS
Use:
fresh water
PROFIPLAST®
PBS-SUB
Temperature:
- 25°C to + 70°C
Rated voltage:
450/750 V
Material:
Profiprene
Version:
450 m - 45 bars
Approval:
AD8 (450 m)
Use:
deep water
PROFIPLAST®
PBS-USE
Temperature:
- 25°C to + 70°C
Rated voltage:
450/750 V
Material:
Profiprene
Approval:
AD8 (250 m)
Use:
waste water
PROFIPLAST®
PBS-USE + Bearer cable
Temperature:
- 25°C to + 70°C
Rated voltage:
450/750 V
Material:
Profiprene
Version:
with bearer
Approval:
AD8 (250 m)
Use:
waste water
PROFIPLAST®
PBS-PLUS
Temperature:
- 40°C to + 80°C
Rated voltage:
450/750 V
Material:
Profiprene
Approval:
AD8 (250 m)
Use:
agressive environment
PROFIPLAST®
PBS-SEA
Temperature:
- 25°C to + 70°C
Rated voltage:
450/750 V
Material:
Profiprene
Approval:
AD8 (250 m)
Use:
marine environment
PROFIPLAST®
PBS-SPOT
Temperature:
- 25°C to + 70°C
Rated voltage:
450/750 V
Material:
Profiprene
Approval:
AD8 (100 m)
Use:
swimming pool
PROFIPLAST®
PBS-POOL
Temperature:
- 25°C to + 70°C
Rated voltage:
300/500 V
Material:
Profiprene
Approval:
AD8 (100 m)
Use:
robotic pool cleaners
PROFIPLAST®
PBS-FLOT
Temperature:
- 25°C to + 70°C
Rated voltage:
300/500 V
Material:
Profiprene
Version:
floating cable
Approval:
AD8 (100 m)
Use:
robotic pool cleaners
PROFIPLAST®
PBS-W
Temperature:
- 25°C to + 70°C
Rated voltage:
450/750 V
Material:
atoxic Profiprene
Approval:
AD8 (250 m), ACS
Use:
agro-food industry
PROFIPLAST®
PBS-M BE
Temperature:
- 25°C to + 70°C
Rated voltage:
300/300 V
Material:
Profiprene
Shielding:
tin-plated copper braid
Approval:
AD8 (100 m)
Use:
measuring devices
PROFIPLAST®
PBS-GARDEN
Temperature:
- 40°C to + 60°C
Rated voltage:
300/300 V, 450/750 V
Material:
PEHD
Version:
buried installations
Use:
spraying control systems
BIO-HABITAT®
H07V-U BPA
Temperature:
- 5°C to + 70°C
Rated voltage:
450/750 V
Material:
PVC
Version:
screened
Approval:
RPC EN 50575
BIO-HABITAT®
H07V-R BPA
Temperature:
- 5°C to + 70°C
Rated voltage:
450/750 V
Material:
PVC
Version:
screened
Approval:
RPC EN 50575
BIO-HABITAT®
H07Z-U BPA
Temperature:
- 5°C to + 70°C
Rated voltage:
450/750 V
Material:
halogen free
Version:
screened
Approval:
RPC EN 50575
BIO-HABITAT®
05VV-U BPA
Temperature:
- 5°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Version:
screened
Approval:
RPC EN 50575
BIO-HABITAT®
H05VV-F BPA
Temperature:
- 5°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Version:
screened
Approval:
RPC EN 50575
SOLARPLAST®
H1Z2Z2-K
Temperature:
- 40°C to + 90°C
Rated voltage:
1.0/1.0 kV A.C
Material:
halogen free
Version:
double insulation
Approval:
EN 50618 (Lloyd's Register)
SOLARPLAST®
TWIN H1Z2Z2-K
Temperature:
- 40°C to + 90°C
Rated voltage:
1.0/1.0 kV A.C
Material:
halogen free
Version:
double insulation, 2 conductors
Approval:
EN 50618 (Lloyd's Register)
SOLARPLAST®
TWIN H1Z2Z2-K
Temperature:
- 40°C to + 90°C
Rated voltage:
1.0/1.0 kV A.C
Material:
halogen free
Version:
double insulation, 2 conductors
Approval:
EN 50618 (Lloyd's Register)
PROFIPLAST®
03ET-F
Temperature:
- 50°C to + 125°C
Rated voltage:
300/300 V
Material:
elastomer thermoplastic
PROFIPLAST®
05ET-F
Temperature:
- 50°C to + 125°C
Rated voltage:
300/500 V
Material:
elastomer thermoplastic
PROFIPLAST®
03ET-F BE
Temperature:
- 50°C to + 125°C
Rated voltage:
300/300 V
Material:
elastomer thermoplastic
Shielding:
tin-plated copper braid
PROFIPLAST®
05ET-F BE
Temperature:
- 50°C to + 125°C
Rated voltage:
300/500 V
Material:
elastomer thermoplastic
Shielding:
tin-plated copper braid
PROFIPLAST®
CLIM-BT HT
Temperature:
- 40°C to + 105°C
Rated voltage:
450/750 V
Material:
PVC
PROFIPLAST®
10V2-K
Temperature:
- 25°C to + 105°C
Rated voltage:
600/1000 V
Material:
PVC 105°C
PROFIPLAST®
10Z1-K
Temperature:
- 25°C to + 105°C
Rated voltage:
600/1000 V
Material:
halogen free
PROFIPLAST®
1000 YY
Temperature:
- 15°C to + 70°C
Rated voltage:
600/1000 V
Material:
PVC
PROFIPLAST®
1000 YCY
Temperature:
- 15°C to + 70°C
Rated voltage:
600/1000 V
Material:
PVC
Shielding:
tin-plated copper braid
PROFIPLAST®
1000 YwCYw
Temperature:
- 25°C to + 105°C
Rated voltage:
600/1000 V
Material:
PVC
Shielding:
tin-plated copper braid
PROFIPLAST®
1000 YCY LSLH
Temperature:
- 15°C to + 70°C
Rated voltage:
600/1000 V
Material:
PVC LSLH
Shielding:
tin-plated copper braid
PROFIPLAST®
1000 LSZH
Temperature:
- 15°C to + 70°C
Rated voltage:
600/1000 V
Material:
halogen free
PROFIPLAST®
1000 LSZH BE
Temperature:
- 15°C to + 70°C
Rated voltage:
600/1000 V
Material:
halogen free
Shielding:
tin-plated copper braid
PROFIPLAST®
1000 YCYRHC1
Temperature:
- 15°C to + 70°C
Rated voltage:
600/1000 V
Material:
PVC HR
Shielding:
tin-plated copper braid
Version:
oil resitant
PROFIPLAST®
1000 YCY LSLH C1
Temperature:
- 5°C to + 60°C
Rated voltage:
600/1000 V
Material:
PVC LSLH
Shielding:
tin-plated copper braid
PROFIPLAST®
1000 2YSLCY-J
Temperature:
- 5°C to + 70°C
Rated voltage:
600/1000 V
Material:
PVC
Version:
shielded (tape and braid)
PROFIPLAST®
1000 GVS RH
Temperature:
- 20°C to + 60°C
Rated voltage:
600/1000 V
Material:
PVC HR
Core:
tin-plated copper
Resistance:
hydrocarbons
MULTI-VX®
BT
Rated voltage:
1000 V max
Version:
hybrid cable
Specific:
customised solution
PROFIPLAST®
FLEX Y
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V, 450/750 V
Material:
extra flexible PVC
Core:
classe 6, extra flexible
PROFIPLAST®
FLEX Yw
Temperature:
- 25°C to + 105°C
Rated voltage:
300/500 V, 450/750 V
Material:
extra flexible PVC
Core:
classe 6, extra flexible
PROFIPLAST®
07V-K6 HT
Temperature:
- 25°C to + 105°C
Rated voltage:
450/750 V
Material:
extra flexible PVC
Core:
classe 6, extra flexible
PROFIPLAST®
FLEX YY
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V
Material:
extra flexible PVC
Core:
classe 6, extra flexible
PROFIPLAST®
FLEX YwYw
Temperature:
- 25°C to + 105°C
Rated voltage:
300/500 V
Material:
extra flexible PVC
Core:
classe 6, extra flexible
ROBOFLEX®
41Qb
Temperature:
- 50°C to + 105°C
Rated voltage:
600/1000 V
Material:
TPE / Polyurethane
Core:
classe 6, extra flexible
Version:
double insulation
ROBOFLEX®
MQb-41
Temperature:
- 50°C to + 105°C
Rated voltage:
300/500 V, 450/750 V
Material:
TPE / Polyurethane
Core:
classe 6, extra flexible
ROBOFLEX®
MQbBE-41
Temperature:
- 50°C to + 105°C
Rated voltage:
300/500 V, 450/750 V
Material:
TPE / Polyurethane
Core:
classe 6, extra flexible
Shielding:
tin-plated copper braid
PROFIPLAST®
LiY
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
PROFIPLAST®
LiYw
Temperature:
- 25°C to + 105°C
Rated voltage:
300/500 V
Material:
PVC
PROFIPLAST®
LiYY
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
PROFIPLAST®
LiYwYw
Temperature:
- 25°C to + 105°C
Rated voltage:
300/500 V
Material:
PVC
PROFIPLAST®
LiYY P
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Version:
multi-pair
PROFIPLAST®
LiYY BPA
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Version:
sreened
PROFIPLAST®
LiYCY
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Shielding:
tin-plated copper braid
Approval:
RPC EN 50575
PROFIPLAST®
LiYwCYw
Temperature:
- 25°C to + 105°C
Rated voltage:
300/500 V
Material:
PVC
Shielding:
tin-plated copper braid
PROFIPLAST®
LiYCY P
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Shielding:
tin-plated copper braid
Version:
multi-pair
PROFIPLAST®
P-MKE
Temperature:
- 25°C to + 105°C
Rated voltage:
500 V
Material:
PVC
Core:
tin-plated copper
Shielding:
tin-plated copper braid
PROFIPLAST®
P-MKA
Temperature:
- 25°C to + 105°C
Rated voltage:
500 V
Material:
PVC
Core:
tin-plated copper
PROFIPLAST®
KY 30
Temperature:
- 20°C to + 105°C
Rated voltage:
250 Vca / 350 Vcc
Material:
PVC
PROFIPLAST®
KY 33 A
Temperature:
- 20°C to + 105°C
Rated voltage:
750 Vca / 1000 Vcc
Material:
PVC
OILPLAST®
YSL-JZ
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Resistance:
to oils and industrial solvents
OILPLAST®
YSL-JZ
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Resistance:
to oils and industrial solvents
OILPLAST®
JZ LSZH
Temperature:
- 20°C to + 70°C
Rated voltage:
300/500 V
Material:
halogen free
OILPLAST®
YSL-C
Temperature:
- 20°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Shielding:
tin-plated copper braid
Resistance:
to oils and industrial solvents
OILPLAST®
YSL-Q
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Version:
armoured
Resistance:
to oils and industrial solvents
OILPLAST®
YSL-EB
Temperature:
- 15°C to + 70°C
Rated voltage:
50 V A.C / 75 V D.C
Material:
PVC
Use:
intrinsic safety
OILPLAST®
YSL-EB-CY
Temperature:
- 15°C to + 70°C
Rated voltage:
50 V A.C / 75 V D.C
Material:
PVC
Shielding:
tin-plated copper braid
Use:
intrinsic safety
PROFIPLAST®
RH EG SF
Temperature:
- 30°C to + 90°C
Rated voltage:
150 V A.C / 220 V D.C
Material:
PVC HR
Version:
sreened
Resistance:
hydrocarbons
PROFIPLAST®
RH EG FA
Temperature:
- 30°C to + 90°C
Rated voltage:
150 V A.C / 220 V D.C
Material:
PVC HR
Version:
screened and armoured
Resistance:
hydrocarbons
PROFIPLAST®
RH EI SF
Temperature:
- 30°C to + 90°C
Rated voltage:
150 V A.C / 220 V D.C
Material:
PVC HR
Version:
sreened
Resistance:
hydrocarbons
PROFIPLAST®
RH EI FA
Temperature:
- 30°C to + 90°C
Rated voltage:
150 V A.C / 220 V D.C
Material:
PVC HR
Version:
screened and armoured
Resistance:
hydrocarbons
SILICABLE®
VMT
Temperature:
- 50°C to + 130°C
Rated voltage:
300/500 V
Material:
composites
SILICABLE®
NMVRI-ES
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V
Material:
composites
SILICABLE®
PVS
Temperature:
- 60°C to + 230°C
Rated voltage:
300/500 V
Material:
composites
SILISOL®
1G, 2G
Temperature:
- 60°C to + 350°C
Rated voltage:
12/24 V
Material:
composites
SILICABLE®
VS
Temperature:
- 60°C to + 280°C
Rated voltage:
300/500 V
Material:
composites
Core:
bare copper
SILICABLE®
TEVS
Temperature:
- 60°C to + 280°C
Rated voltage:
300/500 V
Material:
composites
Core:
bare copper
SILICABLE®
TEVS
Temperature:
- 60°C to + 280°C
Rated voltage:
300/500 V
Material:
composites
Core:
bare copper
SILICABLE®
CNVS
Temperature:
- 60°C to + 280°C
Rated voltage:
300/500 V
Material:
composites
Core:
nickel-plated copper
SILICABLE®
NVS, NVSL
Temperature:
- 60°C to + 350°C
Rated voltage:
300/500 V, 300/300 V
Material:
composites
Core:
nickel
SILISOL®
NTSD-L, NTSD
Temperature:
- 60°C to + 400°C
Rated voltage:
300/500 V
Material:
composites
Core:
concentric nickel
SILICABLE®
CNVAS
Temperature:
- 60°C to + 400°C
Rated voltage:
300/500 V
Material:
composites
Core:
nickel-plated copper (bare copper core in option : VAS )
SILICABLE®
NVAS
Temperature:
- 60°C to + 450°C
Rated voltage:
300/500 V
Material:
composites
Core:
nickel
SILICABLE®
Style 5167
Temperature:
- 60°C to + 250°C
Rated voltage:
300 V
Material:
composites
Core:
nickel-plated copper or nickel
Approval:
UL
SILICABLE®
Style 5257
Temperature:
- 60°C to + 250°C
Rated voltage:
300 V
Material:
composites
Core:
nickel-plated copper or nickel
Approval:
UL
SILICABLE®
Style 5256
Temperature:
- 60°C to + 250°C
Rated voltage:
600 V
Material:
composites
Core:
nickel-plated copper or nickel
Approval:
UL
SILICABLE®
Style 5196
Temperature:
- 60°C to + 250°C
Rated voltage:
600 V
Material:
composites
Core:
nickel-plated copper or nickel
Approval:
UL
SILICABLE®
Style 5125
Temperature:
- 60°C to + 250°C
Rated voltage:
600 V
Material:
composites
Core:
nickel-plated copper or nickel
Approval:
UL
SILICABLE®
Style 5294
Temperature:
- 60°C to + 350°C
Rated voltage:
300 V
Material:
composites
Core:
nickel-plated copper or nickel
Approval:
UL
SILICABLE®
Style 5285
Temperature:
- 60°C to + 350°C
Rated voltage:
300 V
Material:
composites
Core:
nickel-plated copper or nickel
Approval:
UL
SILICABLE®
Style 5304 VW-1
Temperature:
- 60°C to + 350°C
Rated voltage:
600 V
Material:
composites
Core:
nickel-plated copper or nickel
Approval:
UL
SILICABLE®
Style 5168
Temperature:
- 60°C to + 450°C
Rated voltage:
300 V
Material:
composites
Core:
nickel-plated copper or nickel
Approval:
UL
SILICABLE®
Style 5334
Temperature:
- 60°C to + 450°C
Rated voltage:
300 V
Material:
composites
Core:
nickel-plated copper or nickel
Approval:
UL
SILICABLE®
Style 5128
Temperature:
- 60°C to + 450°C
Rated voltage:
300 V
Material:
composites
Core:
nickel-plated copper or nickel
Approval:
UL
SILICABLE®
Style 5335
Temperature:
- 60°C to + 450°C
Rated voltage:
600 V
Material:
composites
Core:
nickel-plated copper or nickel
Approval:
UL
SILICABLE®
Style 5107
Temperature:
- 60°C to + 450°C
Rated voltage:
600 V
Material:
composites
Core:
nickel-plated copper or nickel
Approval:
UL
SILICABLE®
Style 5138
Temperature:
- 60°C to + 450°C
Rated voltage:
600 V
Material:
composites
Core:
nickel-plated copper or nickel
Approval:
UL
SILICABLE®
KVS
Temperature:
- 100°C to + 350°C
Rated voltage:
300/500 V
Material:
polyimide tapes
Core:
bare copper
SILICABLE®
2KVS
Temperature:
- 100°C to + 350°C
Rated voltage:
300/500 V
Material:
two heat-sealed crossed polyimide tapes
Core:
bare copper
SILICABLE®
CN2K
Temperature:
- 190°C to + 250°C
Rated voltage:
300/500 V
Material:
two heat-sealed crossed polyimide tapes
Core:
bare copper
SILICABLE®
CN4K
Temperature:
- 190°C to + 250°C
Rated voltage:
300/500 V
Material:
four heat-sealed crossed polyimide tapes
Core:
bare copper
SILICABLE®
MV-CS
Temperature:
- 60°C to + 200°C
Rated voltage:
600/1000 V
Material:
composites
Core:
bare copper
SILICABLE®
MV-VS
Temperature:
- 60°C to + 280°C
Rated voltage:
300/500 V
Material:
composites
Core:
bare copper
SILICABLE®
MA-CNVS
Temperature:
- 60°C to + 350°C
Rated voltage:
300/500 V
Material:
composites
Core:
nickel-plated copper
SILICABLE®
BM-NVS
Temperature:
- 60°C to + 350°C
Rated voltage:
300/500 V
Material:
composites
Core:
nickel
Shielding:
galvanised steel braid
SILICABLE®
MA-CNVAS
Temperature:
- 60°C to + 400°C
Rated voltage:
300/500 V
Material:
composites
Core:
nickel-plated copper
SILICABLE®
MA-NVAS
Temperature:
- 60°C to + 450°C
Rated voltage:
300/500 V
Material:
composites
Core:
nickel
SILIFLAM®
THS 1000
Temperature:
+ 400°C to + 800°C (indicative values)
Rated voltage:
300/500 V to 600/1000 V
Material:
composites
SILIFLAM®
THS 1200
Temperature:
+ 500°C to + 1000°C (indicative values)
Rated voltage:
300/500 V to 600/1000 V
Material:
composites
SILIFLAM®
THS 1400
Temperature:
+ 700°C to + 1200°C (indicative values)
Rated voltage:
300/500 V to 600/1000 V
Material:
composites
SILIFLAM®
THS 1500
Temperature:
+ 900°C to + 1400°C (indicative values)
Rated voltage:
300/500 V to 600/1000 V
Material:
composites
SILIFLAM®
THS - Operating temperatures and parameters
Temperature:
until + 1400°C (indicative values)
Rated voltage:
300/500 V to 600/1000 V
PROFIPLAST®
CSA
Temperature:
- 15°C to + 70°C
Rated voltage:
600 V
Material:
PVC
PROFIPLAST®
CSA Ird
Temperature:
- 15°C to + 70°C
Rated voltage:
600 V
Material:
PVC
Version:
thin wall insulation
PROFIPLAST®
CSA ADR
Temperature:
- 15°C to + 70°C
Rated voltage:
600 V
Material:
PVC ADR
PROFIPLAST®
CSA ADR Ird
Temperature:
- 15°C to + 70°C
Rated voltage:
600 V
Material:
PVC ADR
Version:
thin wall insulation
PROFIPLAST®
ADR
Temperature:
- 15°C to + 70°C
Rated voltage:
300 V
Material:
PVC ADR
Version:
flat cable
PROFIPLAST®
48 AU IN
Temperature:
-40°C to +85°C
Rated voltage:
600 V
Material:
PVC
PROFIPLAST®
48 AU IN HT
Temperature:
-40°C to +105°C
Rated voltage:
600 V
Material:
PVC 105°C
PROFIPLAST®
48 AU IN THT
Temperature:
-40°C to +125°C
Rated voltage:
600 V
Material:
PVC 125°C
PROFIPLAST®
48 AU Ird
Temperature:
-40°C to +85°C
Rated voltage:
600 V
Material:
PVC
Version:
thin wall insulation
PROFIPLAST®
48 AU Ird HT
Temperature:
-40°C to +105°C
Rated voltage:
600 V
Material:
PVC 105°C
Version:
thin wall insulation
PROFIPLAST®
48 AU Ird THT
Temperature:
-40°C to +125°C
Rated voltage:
600 V
Material:
PVC 125°C
Version:
thin wall insulation
PYRISOL®
500 EN CR1-C1
Rated voltage:
300/500 V
Material:
fire resistant
PYRITEL®
100 EN CR1-C1
Rated voltage:
100/170 V
Material:
fire resistant
Version:
sreened
PYRISOL®
500 ENA CR1-C1
Rated voltage:
300/500 V
Material:
fire resistant
Version:
armoured
PYRISOL®
500 BEL
Rated voltage:
300/500 V
Material:
fire resistant
PYRITEL®
100 BEL
Rated voltage:
100/170 V
Material:
fire resistant
Version:
sreened
SILIFLAM®
500 TX-K CR1-C1
Rated voltage:
300/500 V
Material:
fire resistant
Core:
flexible
SILIFLAM®
500 TX-K BE CR1-C1
Rated voltage:
300/500 V
Material:
fire resistant
Core:
flexible
Shielding:
tin-plated copper braid
SILIFLAM®
500 TEL-EI/EG CR1-C1
Rated voltage:
100/170 V
Material:
fire resistant
Version:
sreened
ELECTROFEU®
ET2002SH CR1-C1 1000V
Rated voltage:
600/1000 V
Material:
fire resistant
TS CABLES®
11 VRtC classe A
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Approval:
RPC EN 50575
TS CABLES®
11 Z1RtC LSZH classe A
Temperature:
- 30°C to + 70°C
Impedance:
75 ohms
Material:
halogen free
TS CABLES®
11 PRtC classe A
Temperature:
- 30°C to + 70°C
Impedance:
75 ohms
Material:
PVC
Use:
external connection
TS CABLES®
11 PRtC AP classe A
Temperature:
- 30°C to + 70°C
Impedance:
75 ohms
Material:
PVC
Version:
with bearer
Use:
external connection
TS CABLES®
11 VAtC Classe A
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Approval:
RPC EN 50575
TS CABLES®
11 PAtC classe A
Temperature:
- 30°C to + 70°C
Impedance:
75 ohms
Material:
polyéthylène
Use:
external connection
COAXDESIGN®
17 VAtC classe B
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Version:
crystal, concrete-grey, alu colours
Use:
design high tech, art moderne, loft
TS CABLES®
17 VAtC classe B
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Approval:
RPC EN 50575
TS CABLES®
17 PAtC classe B
Temperature:
- 30°C to + 70°C
Impedance:
75 ohms
Material:
halogen free
Use:
external connection
TS CABLES®
17 VAtC classe A
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Approval:
RPC EN 50575
TS CABLES®
17 VAtCPH classe A
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Approval:
RPC EN 50575
TS CABLES®
17 PAtC classe A
Temperature:
- 30°C to + 70°C
Impedance:
75 ohms
Material:
halogen free
Use:
external connection
TS CABLES®
FP 1000® classe A
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
TS CABLES®
17 VRtC classe A
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Approval:
RPC EN 50575
TS CABLES®
17 PRtC classe A
Temperature:
- 30°C to + 70°C
Impedance:
75 ohms
Material:
halogen free
Use:
external connection
TS CABLES®
K1000® classe A
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Specific:
suitable for compression connectors
TS CABLES®
Connecteur CLIP F1000®
Composition:
coaxial K1000®
Connector:
FLIP F1000®
TS CABLES®
17 Z1AtC LSZH classe A
Temperature:
- 30°C to + 70°C
Impedance:
75 ohms
Material:
halogen free
TS CABLES®
KX 3B (RG 174/U)
Temperature:
- 30°C to + 80°C
Impedance:
50 ohms
Material:
PVC
TS CABLES®
KX 4 (RG 213/U)
Temperature:
- 30°C to + 80°C
Impedance:
50 ohms
Material:
PVC
TS CABLES®
KX 13 (RG 214/U)
Temperature:
- 30°C to + 80°C
Impedance:
50 ohms
Material:
PVC
TS CABLES®
KX 15 (RG 58C/U)
Temperature:
- 30°C to + 80°C
Impedance:
50 ohms
Material:
PVC
VIDEOCOAX®
KX 6A
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Approval:
RPC EN 50575
VIDEOCOAX®
RG 59 BU
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Approval:
RPC EN 50575
VIDEOCOAX®
KX 8 (RG 11/U)
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Approval:
RPC EN 50575
VIDEOCOAX®
TRIAXIAL KX 8
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Use:
long distance until 800 m
VIDEOCOAX®
75
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Use:
long distance until 500 m
COAXFLASH®
75
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Version:
wide range of colours
Use:
long distance until 500 m
VIDEOCOAX®
100
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Use:
long distance until 500 m
VIDEOCOAX®
RG 59 MINI
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Size:
small
Use:
space saving
VIDEOCOAX®
RG 59 MINI
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Size:
small
Use:
space saving
VIDEOCOAX®
RG 6 LSZH
Temperature:
- 40°C to + 85°C
Impedance:
75 ohms
Material:
halogen free
Version:
improved fire performance
VIDEOCOAX®
RG 11 LSZH
Temperature:
- 40°C to + 85°C
Impedance:
75 ohms
Material:
halogen free
Version:
improved fire performance
VIDEOCOAX®
RG 59 LSZH
Temperature:
- 40°C to + 85°C
Impedance:
75 ohms
Material:
halogen free
Version:
improved fire performance
VIDEOCOAX®
HD
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
PVC
Approval:
RPC EN 50575
Use:
signaux vidéo HD
MULTI-VX®
1024
Composition:
coaxial KX 6A and 2 conductors 0.75 mm²
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
extra flexible PVC
Approval:
RPC EN 50575
MULTI-VX®
1039
Composition:
coaxial and control cables
Temperature:
- 30°C to + 80°C
Rated voltage:
300 / 500 V
Impedance:
75 ohms
Material:
PVC
Use:
long distance
MULTI-VX®
1159
Composition:
coaxial KX 6A and 2 conductors 0.75 mm²
Temperature:
- 30°C to + 80°C
Rated voltage:
300 / 500 V
Impedance:
75 ohms
Material:
PVC
Approval:
RPC EN 50575
MULTI-VX®
1163
Composition:
coaxial and 2 conductors 0.75 mm²
Temperature:
- 30°C to + 80°C
Rated voltage:
450 / 750 V
Impedance:
75 ohms
Material:
PVC
Approval:
RPC EN 50575
TS CABLES®
17 VAtC classe B Dca
Temperature:
- 30°C to + 80°C
Impedance:
75 ohms
Material:
halogen free
Approval:
RPC EN 50575 (Dca-s2, d2, a2)
VARPREN® RW
EN 50306-2 300V M
Temperature:
- 40°C to + 105°C
Rated voltage:
300/500 V
Material:
Varpren®
VARPREN® RW
EN 50306-3 300V MM S
Temperature:
- 40°C to + 105°C
Rated voltage:
300/500 V
Material:
Varpren®
Shielding:
tin-plated copper braid
VARPREN® RW
EN 50306-4 300V MM 1E 1P
Temperature:
- 40°C to + 90°C
Rated voltage:
300/500 V
Material:
Varpren®
VARPREN® RW
EN 50306-4 300V MM S 3E 3P
Temperature:
- 40°C to + 90°C
Rated voltage:
300/500 V
Material:
Varpren®
Shielding:
tin-plated copper braid
VARPREN® RW
EN 50306-4 300V MMM S 5E 5P
Temperature:
- 40°C to + 90°C
Rated voltage:
300/500 V
Material:
Varpren®
Shielding:
tin-plated copper braid (individual)
Version:
twisted pairs
VARPREN® RW
EN 50306-4 300V MM S 7E 7P
Temperature:
- 40°C to + 90°C
Rated voltage:
300/500 V
Material:
Varpren®
Shielding:
tin-plated copper braid (general)
Version:
twisted pairs
VARPREN® RW
EN 50264-2-1 600V M
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
VARPREN® RW
EN 50264-2-1 1800V M
Temperature:
- 40°C to + 90°C
Rated voltage:
1.8 /3 kV
Material:
Varpren®
VARPREN® RW
EN 50264-2-1 1800V MM
Temperature:
- 40°C to + 90°C
Rated voltage:
1.8 /3 kV
Material:
Varpren®
VARPREN® RW
EN 50264-2-1 3600V MM
Temperature:
- 40°C to + 90°C
Rated voltage:
3.6 /6 kV
Material:
Varpren®
VARPREN® RW
EN 50264-2-2 300V MM
Temperature:
- 40°C to + 90°C
Rated voltage:
300/500 V
Material:
Varpren®
VARPREN® RW
EN 50264-2-2 600V MM
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
VARPREN® RW
EN 50264-2-2 300V MM S
Temperature:
- 40°C to + 90°C
Rated voltage:
300/500 V
Material:
Varpren®
Shielding:
tin-plated copper braid
VARPREN® RW
EN 50264-2-2 600V MM S
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
Shielding:
tin-plated copper braid
VARPREN® RW
EN 50264-2-1 600V MM S
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
Shielding:
tin-plated copper braid
VARPREN® RW
EN 50264-2-1 1800V MM S
Temperature:
- 40°C to + 90°C
Rated voltage:
1.8 /3 kV
Material:
Varpren®
Shielding:
tin-plated copper braid
VARPREN® RW
EN 50264-2-1 3600V MM S
Temperature:
- 40°C to + 90°C
Rated voltage:
3.6 /6 kV
Material:
Varpren®
Shielding:
tin-plated copper braid
VARPREN® RW
EN 50264-3-1 600V M
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
VARPREN® RW
EN 50264-3-1 1800V M
Temperature:
- 40°C to + 90°C
Rated voltage:
1.8 /3 kV
Material:
Varpren®
VARPREN® RW
EN 50264-3-1 1800V MM
Temperature:
- 40°C to + 90°C
Rated voltage:
1.8 /3 kV
Material:
Varpren®
VARPREN® RW
EN 50264-3-1 3600V MM
Temperature:
- 40°C to + 90°C
Rated voltage:
3.6 /6 kV
Material:
Varpren®
VARPREN® RW
EN 50264-3-2 300V MM
Temperature:
- 40°C to + 90°C
Rated voltage:
300/500 V
Material:
Varpren®
VARPREN® RW
EN 50264-3-2 600V MM
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
VARPREN® RW
EN 50264-3-2 300V MM S
Temperature:
- 40°C to + 90°C
Rated voltage:
300/500 V
Material:
Varpren®
Shielding:
tin-plated copper braid
VARPREN® RW
EN 50264-3-2 600V MM S
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
Shielding:
tin-plated copper braid
SILICABLE® RW
EN 50382-2 1800V F 120°C
Temperature:
- 40°C to + 120°C
Rated voltage:
1.8 /3 kV
Material:
silicone
SILICABLE® RW
EN 50382-2 1800V F 150°C
Temperature:
- 40°C to + 150°C
Rated voltage:
1.8 /3 kV
Material:
silicone
SILICABLE® RW
EN 50382-2 3600V F 120°C
Temperature:
- 40°C to + 120°C
Rated voltage:
3.6 /6 kV
Material:
silicone
SILICABLE® RW
EN 50382-2 3600V F 150°C
Temperature:
- 40°C to + 150°C
Rated voltage:
3.6 /6 kV
Material:
silicone
SILICABLE® RW
EN 50382-2 1800V FF 120°C
Temperature:
- 40°C to + 120°C
Rated voltage:
1.8 /3 kV
Material:
silicone
SILICABLE® RW
EN 50382-2 1800V FF 150°C
Temperature:
- 40°C to + 150°C
Rated voltage:
1.8 /3 kV
Material:
silicone
SILICABLE® RW
EN 50382-2 3600V FF 120°C
Temperature:
- 40°C to + 120°C
Rated voltage:
3.6 /6 kV
Material:
silicone
SILICABLE® RW
EN 50382-2 3600V FF 150°C
Temperature:
- 40°C to + 150°C
Rated voltage:
3.6 /6 kV
Material:
silicone
SILICABLE® RW
EN 50382-2 3600V FXZ 120°C
Temperature:
- 40°C to + 120°C
Rated voltage:
3.6 /6 kV
Material:
silicone
SILICABLE® RW
EN 50382-2 3600V FXZ 150°C
Temperature:
- 40°C to + 150°C
Rated voltage:
3.6 /6 kV
Material:
silicone
SILICABLE® RW
EN 50382-2 3600V FXZ 150°C
Temperature:
- 40°C to + 150°C
Rated voltage:
3.6 /6 kV
Material:
silicone
SILICABLE® RW
EN 50382-2 1800V FF S 120°C
Temperature:
- 40°C to + 120°C
Rated voltage:
1.8 /3 kV
Material:
silicone
Shielding:
tin-plated copper braid
SILICABLE® RW
EN 50382-2 1800V FF S 120°C
Temperature:
- 40°C to + 120°C
Rated voltage:
1.8 /3 kV
Material:
silicone
Shielding:
tin-plated copper braid
SILICABLE® RW
EN 50382-2 3600V FF S 120°C
Temperature:
- 40°C to + 150°C
Rated voltage:
3.6 /6 kV
Material:
silicone
Shielding:
tin-plated copper braid
SILICABLE® RW
EN 50382-2 3600V FFXZ S 120°C
Temperature:
- 40°C to + 120°C
Rated voltage:
3.6 /6 kV
Material:
silicone
Shielding:
tin-plated copper braid
VARPREN® RW
EN 50264-2-1 600V M FR
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
VARPREN® RW
EN 50264-2-1 1800V M FR
Temperature:
- 40°C to + 90°C
Rated voltage:
1.8 /3 kV
Material:
Varpren®
VARPREN® RW
EN 50264-2-2 300V MM FR
Temperature:
- 40°C to + 90°C
Rated voltage:
300/500 V
Material:
Varpren®
VARPREN® RW
EN 50264-2-2 600V MM FR
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
VARPREN® RW
EN 50264-2-2 300V MM S FR
Temperature:
- 40°C to + 90°C
Rated voltage:
300/500 V
Material:
Varpren®
Shielding:
tin-plated copper braid
VARPREN® RW
EN 50264-2-2 600V MM S FR
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
Shielding:
tin-plated copper braid
VARPREN® RW
EN 50264-3-1 600V M FR
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
VARPREN® RW
EN 50264-3-2 300V MM FR
Temperature:
- 40°C to + 90°C
Rated voltage:
300/500 V
Material:
Varpren®
VARPREN® RW
EN 50264-3-2 600V MM FR
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
VARPREN® RW
EN 50264-3-2 300V MM S FR
Temperature:
- 40°C to + 90°C
Rated voltage:
300/500 V
Material:
Varpren®
Shielding:
tin-plated copper braid
VARPREN® RW
EN 50264-3-2 600V MM S FR
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
Shielding:
tin-plated copper braid
DATARAIL®
100BE85EM101 4x0.5 mm²
Temperature:
- 25°C to + 85°C
Impedance:
100 ohms
Material:
halogen free
Shielding:
double: tape and braid
Version:
improved fire performance
Specific:
EN 45545-2
TS LAN®
Cat 5e U/UTP LSZH
Temperature:
- 20°C to + 70°C
Impedance:
100 ohms
Material:
halogen free
Approval:
RPC EN 50575
TS LAN®
Cat 5e F/UTP LSZH
Temperature:
- 20°C to + 70°C
Impedance:
100 ohms
Material:
halogen free
Version:
sreened
Approval:
RPC EN 50575
TS LAN®
Cat 6 U/UTP LSZH
Temperature:
- 20°C to + 70°C
Impedance:
100 ohms
Material:
halogen free
Approval:
RPC EN 50575
TS LAN®
Cat 6 F/UTP LSZH
Temperature:
- 20°C to + 70°C
Impedance:
100 ohms
Material:
halogen free
Version:
sreened
Approval:
RPC EN 50575 (Dca)
TS LAN®
Cat 6 U/FTP LSZH
Temperature:
- 20°C to + 70°C
Impedance:
100 ohms
Material:
halogen free
Version:
screened
Approval:
RPC EN 50575
TS LAN®
Cat 6A F/UTP LSZH
Temperature:
- 20°C to + 70°C
Impedance:
100 ohms
Material:
halogen free
Version:
screened
Approval:
RPC EN 50575 (Dca)
TS LAN®
Cat 6A U/FTP LSZH
Temperature:
- 20°C to + 70°C
Impedance:
100 ohms
Material:
halogen free
Version:
screened
Approval:
RPC EN 50575 (Dca)
TS LAN®
Cat 6A F/FTP LSZH
Temperature:
- 20°C to + 70°C
Impedance:
100 ohms
Material:
halogen free
Version:
screened
Approval:
RPC EN 50575 (Dca)
TS LAN®
Cat 6A SF/UTP LSZH
Temperature:
- 20°C to + 70°C
Impedance:
100 ohms
Material:
halogen free
Version:
screened and shielded
TS LAN®
Cat 7 S/FTP LSZH
Temperature:
- 20°C to + 70°C
Impedance:
100 ohms
Material:
halogen free
Version:
screened and shielded
Approval:
RPC EN 50575 (Dca)
TS LAN®
Cat 7A S/FTP LSZH
Temperature:
- 20°C to + 70°C
Impedance:
100 ohms
Material:
halogen free
Version:
screened and shielded
Approval:
RPC EN 50575 (Dca)
TEXALARM®
MULTI EV6S CCA
Temperature:
- 30°C to + 80°C
Material:
PVC
Core:
copper plated aluminium
Approval:
RPC EN 50575
TEXALARM®
MULTI EV6S
Temperature:
- 30°C to + 80°C
Material:
PVC
Core:
bare copper
TEXALARM®
MONO EV6R CCA
Temperature:
- 30°C to + 80°C
Material:
PVC
Core:
copper plated aluminium
Approval:
RPC EN 50575
TEXALARM®
MONO EV6R
Temperature:
- 30°C to + 80°C
Material:
PVC
Core:
bare copper
Approval:
RPC EN 50575
MULTI-VX®
EI EG 2A1P9C
Composition:
2p0.40 + 1p0.60 + 9x0.22 mm²
Temperature:
- 30°C to + 80°C
Material:
PVC
Version:
hybrid cable
ODIOSIS®
EI EG 2A1P9C
Temperature:
- 5°C to + 70°C
Material:
PVC
Version:
flat cable
Approval:
RPC EN 50575
ODIOSIS®
HP-R
Temperature:
- 5°C to + 70°C
Material:
PVC
Approval:
RPC EN 50575
ODIOSIS®
HP-GARDEN
Composition:
2x2.5 mm²
Temperature:
- 5°C to + 70°C
Rated voltage:
300V
Material:
polyéthylène
Use:
outside or buried
ODIOSIS®
MIC
Composition:
1 to 5 conductors 0.22 mm²
Temperature:
- 5°C to + 70°C
Material:
extra flexible PVC
Core:
flexible bare copper
Shielding:
bare copper braid
ODIOSIS®
Audio Modulation XP
Composition:
2x0.34 mm²
Temperature:
- 5°C to + 70°C
Impedance:
75 ohms
Material:
PVC
Core:
flexible tin-plated copper
Version:
screened
ODIOSIS®
Audio Modulation MP
Composition:
2 pairs 0.5 mm²
Temperature:
- 5°C to + 70°C
Impedance:
75 ohms
Material:
PVC
Core:
flexible tin-plated copper
Version:
each pair screened
ODIOSIS®
V2AN
Composition:
1 to 5 coaxial cables
Temperature:
- 5°C to + 70°C
Impedance:
75 ohms
Material:
PVC
Core:
flexible tin-plated copper
Shielding:
tin-plated copper braid
ENERSYL®
ZH POWER 1x
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
HFFR
ENERSYL®
ZH POWER Multi
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
HFFR
ENERSYL®
ZH CONTROL
Temperature:
- 30°C to + 80°C
Rated voltage:
450/750 V
Material:
HFFR
ENERSYL®
ZH INSTRUM
Temperature:
- 30°C to + 80°C
Rated voltage:
300/500 V
Material:
HFFR
Shielding:
braid and/or tape
COUPLIX®
ZH JX, KX, EX, TX, BC, KCB
Temperature:
- 30°C to + 80°C
Couple:
JX, TX, KX, EX, BC, KCB
Material:
HFFR
ENERSYL®
HT POWER 1x
Temperature:
- 60°C to + 200°C
Rated voltage:
600/1000 V
Material:
silicone
ENERSYL®
HT POWER Multi
Temperature:
- 60°C to + 200°C
Rated voltage:
600/1000 V
Material:
silicone
ENERSYL®
HT CONTROL
Temperature:
- 60°C to + 200°C
Rated voltage:
450/750 V
Material:
silicone
ENERSYL®
HT INSTRUM
Temperature:
- 60°C to + 200°C
Rated voltage:
300/500 V
Material:
silicone
Shielding:
braid and/or tape
COUPLIX®
HT JX, KX, EX, TX, BC, KCB
Temperature:
- 60°C to + 200°C
Couple:
JX, TX, KX, EX, BC, KCB
Material:
silicone
ENERSYL®
FR POWER 1x
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
HFFR
ENERSYL®
FR POWER Multi
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
HFFR
ENERSYL®
FR CONTROL
Temperature:
- 30°C to + 80°C
Rated voltage:
450/750 V
Material:
HFFR
ENERSYL®
FR INSTRUM
Temperature:
- 30°C to + 80°C
Rated voltage:
300/500 V
Material:
HFFR
Shielding:
braid and/or tape
COUPLIX®
FR JX, KX, EX, TX, BC, KCB
Temperature:
- 30°C to + 80°C
Couple:
JX, TX, KX, EX, BC, KCB
Material:
HFFR
ENERSYL®
LH POWER 1x
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
thermoplastic PVC
ENERSYL®
LH POWER Multi
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
thermoplastic PVC
ENERSYL®
LH CONTROL
Temperature:
- 30°C to + 80°C
Rated voltage:
450/750 V
Material:
thermoplastic PVC
ENERSYL®
LH INSTRUM
Temperature:
- 30°C to + 80°C
Rated voltage:
300/500 V
Material:
thermoplastic PVC
Shielding:
braid and/or tape
COUPLIX®
LH JX, KX, EX, TX, BC, KCB
Temperature:
- 30°C to + 80°C
Couple:
JX, TX, KX, EX, BC, KCB
Material:
thermoplastic PVC
ENERSYL®
RH POWER 1x
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
thermoplastic PVC
ENERSYL®
RH POWER Multi
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
thermoplastic PVC
ENERSYL®
RH CONTROL
Temperature:
- 30°C to + 80°C
Rated voltage:
450/750 V
Material:
thermoplastic PVC
ENERSYL®
RH INSTRUM
Temperature:
- 30°C to + 80°C
Rated voltage:
300/500 V
Material:
thermoplastic PVC
Version:
sreened
COUPLIX®
RH JX, KX, EX, TX, BC, KCB
Temperature:
- 30°C to + 80°C
Couple:
JX, TX, KX, EX, BC, KCB
Material:
thermoplastic PVC
ENERSYL®
OS SHF1 POWER 1x
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
halogen free
ENERSYL®
OS SHF1 POWER Multi
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
halogen free
ENERSYL®
OS SHF1 CONTROL
Temperature:
- 30°C to + 80°C
Rated voltage:
450/750 V
Material:
halogen free
ENERSYL®
OS SHF1 INSTRUM
Temperature:
- 30°C to + 80°C
Rated voltage:
300/500 V
Material:
halogen free
ENERSYL®
OS 331 SHF1 POWER 1x
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
halogen free
ENERSYL®
OS 331 SHF1 POWER Multi
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
halogen free
ENERSYL®
OS 331 SHF1 CONTROL
Temperature:
- 30°C to + 80°C
Rated voltage:
450/750 V
Material:
halogen free
ENERSYL®
OS 331 SHF1 INSTRUM
Temperature:
- 30°C to + 80°C
Rated voltage:
300/500 V
Material:
halogen free
VARPREN®
MAX
Temperature:
- 30°C to + 125°C
Rated voltage:
600/1000 V
Material:
Varpren®
MULTIMAX®
MAX
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
halogen free
MULTIMAX®
CF BL
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
halogen free
Version:
armoured
MULTIMAX®
CF 331
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
halogen free
MULTIMAX®
CF BL 331
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
halogen free
Version:
armoured
MULTIMAX®
CI
Temperature:
- 30°C to + 80°C
Rated voltage:
150/250 V
Material:
halogen free
MULTIMAX®
CI EG / EI
Temperature:
- 30°C to + 80°C
Rated voltage:
150/250 V
Material:
halogen free
Version:
sreened
MULTIMAX®
CI BL
Temperature:
- 30°C to + 80°C
Rated voltage:
150/250 V
Material:
halogen free
Version:
armoured
MULTIMAX®
CI BL EG / EI
Temperature:
- 30°C to + 80°C
Rated voltage:
150/250 V
Material:
halogen free
Version:
armoured
MULTIMAX®
CI 331
Temperature:
- 30°C to + 80°C
Rated voltage:
150/250 V
Material:
halogen free
MULTIMAX®
CI 331 EG / EI
Temperature:
- 30°C to + 80°C
Rated voltage:
150/250 V
Material:
halogen free
Version:
sreened
MULTIMAX®
CI BL 331
Temperature:
- 30°C to + 80°C
Rated voltage:
150/250 V
Material:
halogen free
Version:
armoured
MULTIMAX®
CI BL 331 EG / EI
Temperature:
- 30°C to + 80°C
Rated voltage:
150/250 V
Material:
halogen free
Version:
sreened
COUPLIX®
Main products COUPLES T, J, E, K, N
Temperature:
- 190°C to + 400°C (depending on references)
Couple:
T, J, E, K, N
Material:
PVC, FEP, PFA, fiberglass, silica fibre, borosilicoaluminate fibre...
Version:
Stainless steel, galvanized steel or tin-plated copper braids (optional)
COUPLIX®
Main products COUPLES KX1, JX1, NX1, EX1, SCA
Temperature:
- 190°C to + 400°C (depending on references)
Couple:
KX1, JX1 , NX1, EX1, SCA
Material:
PVC, FEP, PFA, fiberglass, silica fibre, borosilicoaluminate fibre...
Version:
Stainless steel, galvanized steel or tin-plated copper braids (optional)
SONDIX®
MC-ETFE, MC-EETFE
Temperature:
- 60°C to + 150°C
Rated voltage:
300V
Material:
ETFE
Version:
shielded (option)
SONDIX®
MC-EFEP, MC-AFEP
Temperature:
- 60°C to + 200°C
Rated voltage:
300V
Material:
FEP
Version:
shielded (option)
SONDIX®
MC-EPFA, MC-APFA, MC-CNPFA
Temperature:
- 60°C to + 260°C
Rated voltage:
300V
Material:
PFA
Version:
shielded (option)
SONDIX®
MC-ECS
Temperature:
- 60°C to + 200°C
Rated voltage:
300V
Material:
silicone
Version:
shielded (option)
SONDIX®
Main products
Temperature:
- 190°C to + 400°C (depending on references)
Material:
PVC, silicone, FEP, PFA, fiberglass...
SILIGAINE®
13F1
Temperature:
- 30°C to + 155°C, Class F
Dielectric strength:
> 1 kV (dry)
Material:
fiberglass with PU coating
SILIGAINE®
13F3
Temperature:
- 30°C to + 155°C, Class F
Dielectric strength:
3 kV (dry, central value)
Material:
fiberglass with PU coating
SILIGAINE®
13F4
Temperature:
- 30°C to + 155°C, Class F
Dielectric strength:
> 4 kV (dry)
Material:
fiberglass with PU coating
SILIGAINE®
16F2
Temperature:
- 30°C to + 155°C, Class F
Dielectric strength:
1.8 kV (dry, central value)
Material:
fiberglass with acrylic coating
SILIGAINE®
16F3
Temperature:
- 30°C to + 155°C, Class F
Dielectric strength:
3.3 kV (dry, central value)
Material:
fiberglass with acrylic coating
SILIGAINE®
16F7 UL
Temperature:
- 30°C to + 155°C, Class F
Dielectric strength:
7 kV (dry, central value)
Material:
fiberglass with acrylic coating
Approval:
UL
SILIGAINE®
15C1.5
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
1.5 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C2
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
2.5 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C3
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 3 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C3-UV
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 3 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C4
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 4 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C4.d
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 4 kV (dry)
Material:
fiberglass (double insulation)
Version:
abrasion resistance
SILIGAINE®
15C5
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 5 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C5-E EXTENSIBLE
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 5 kV (dry)
Material:
fiberglass with silicone coating
Version:
expandable
SILIGAINE®
15C7 GRADE A UL
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 7 kV (dry)
Material:
fiberglass with silicone coating
Version:
expandable
SILIGAINE®
15C10
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 10 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
21F1
Temperature:
- 60°C to + 280°C
Dielectric strength:
0.8 to 1.2 kV (dry)
Material:
treated fiberglass with clear silicone varnish coating
SILIGAINE®
24C1
Temperature:
- 60°C to + 350°C
Dielectric strength:
0.8 to 1.2 kV (dry)
Material:
fiberglass treated and impregnated with silicone resin
SILIGAINE®
31-1
Temperature:
- 60°C to + 450°C
Material:
treated fiberglass
Version:
not impregnated
SILIGAINE®
31C1E EXTENSIBLE
Temperature:
- 60°C to + 350°C
Material:
fiberglass high temperature treated and impregnated
Version:
expandable and very flexible
SILIGAINE®
GT1
Temperature:
- 60°C to + 300°C
Dielectric strength:
> 800 V (dry)
Material:
treated fiberglass
Version:
not impregnated
SILIGAINE®
GT1
Temperature:
- 60°C to + 250°C
Dielectric strength:
> 1.5 kV (dry)
Material:
treated fiberglass
SILIGAINE®
33SI
Temperature:
+ 900°C (peak + 1050°C)
Material:
silica fibre
Version:
not treated, not impregnated
SILIGAINE®
GSIL
Temperature:
+ 1050°C (peak + 1200°C)
Material:
ultra pure silica fibre
Version:
not treated, not impregnated
SILIGAINE®
33NX
Temperature:
+ 1200°C (peak + 1400°C)
Material:
borosilicoaluminate fibre
Version:
not treated, not impregnated
SILIGAINE®
22P1
Temperature:
+ 130°C, Class B
Dielectric strength:
0.8 to 1.2 kV (dry)
Material:
polyester slightly impregnated
Version:
resistance to freon gas
SILITUBE®
X - FIREPROOF SLEEVING
Temperature:
- 60°C to + 260°C (1 min 1500°C)
Material:
mineral fibre with silicone coating
Version:
improved fire performance
VEROX®
GPAD, TM-FDV-C
Temperature:
- 20°C to + 500°C
Material:
fiberglass
Version:
fascia joints
Use:
special pyrolysis
VEROX®
JHIV1, JHIV2
Temperature:
- 20°C to + 500°C
Material:
fiberglass
Version:
interglass seals
Use:
special pyrolysis
VEROX®
TM-FDV, JHIV B
Temperature:
- 100°C to + 1050°C
Material:
fiberglass
Version:
fascia joints
Resistance:
to very high temperature
ELECTROAIR®
EN 2266-003 CF Line
Temperature:
- 55°C to + 200°C
Rated voltage:
600 V
Material:
Polyimide
Core:
nickel-plated copper
ELECTROAIR®
EN 2713-007 CF Line
Temperature:
- 55°C to + 200°C
Rated voltage:
600 V
Material:
Polyimide
Core:
nickel-plated copper
Shielding:
nickel-plated copper spiral shield
ELECTROAIR®
EN 2267-007 DM Line
Temperature:
- 55°C to + 260°C
Rated voltage:
600 V
Material:
Polyimide / PTFE
Core:
nickel-plated copper
Resistance:
arc tracking
ELECTROAIR®
EN 2714-011 DM Line
Temperature:
- 55°C to + 260°C
Rated voltage:
600 V
Material:
Polyimide / PTFE
Core:
nickel-plated copper
Shielding:
nickel-plated copper spiral shield
Resistance:
arc tracking
ELECTROAIR®
DA6007
Temperature:
- 55°C to + 200°C
Rated voltage:
600 V
Material:
Polyimide / PTFE
Core:
silve- plated copper
ELECTROAIR®
DA6010
Temperature:
- 55°C to + 150°C
Rated voltage:
600 V
Material:
Polyimide / PTFE
Core:
silve- plated copper
Shielding:
tin-plated copper spiral shield
ELECTROAIR®
NEMA HP3 ET
Temperature:
- 90°C to + 200°C
Rated voltage:
250 V
Material:
PTFE
Core:
silve- plated copper
ELECTROAIR®
NEMA HP3 E
Temperature:
- 90°C to + 200°C
Rated voltage:
600 V
Material:
PTFE
Core:
silve- plated copper
ELECTROAIR®
NEMA HP3 EE
Temperature:
- 90°C to + 200°C
Rated voltage:
1000 V
Material:
PTFE
Core:
silve- plated copper
ELECTROAIR®
NEMA HP4 KT
Temperature:
- 55°C to + 200°C
Rated voltage:
250 V
Material:
FEP
Core:
silve- plated copper
Resistance:
arc tracking
ELECTROAIR®
NEMA HP4 K
Temperature:
- 55°C to + 200°C
Rated voltage:
600 V
Material:
FEP
Core:
silve- plated copper
Resistance:
arc tracking
ELECTROAIR®
NEMA HP4 KK
Temperature:
- 55°C to + 200°C
Rated voltage:
1000 V
Material:
FEP
Core:
silve- plated copper
Resistance:
arc tracking
ELECTROAIR®
M6BA-A6
Temperature:
- 55°C to + 200°C
Rated voltage:
600 V
Material:
FEP
Core:
silve- plated copper
Shielding:
silver-plated copper braid
Resistance:
arc tracking
ELECTROAIR®
MEEBA-AEE
Temperature:
- 90°C to + 200°C
Rated voltage:
600 V
Material:
PTFE
Core:
silve- plated copper
Shielding:
silver-plated copper braid
ELECTROAIR®
KU 01, 03, 04
Temperature:
- 55°C to + 150°C
Rated voltage:
600 V
Material:
ETFE
Core:
tin-plated copper
ELECTROAIR®
KU 02, 05, 06
Temperature:
- 55°C to + 150°C
Rated voltage:
600 V
Material:
ETFE
Core:
tin-plated copper
Shielding:
tin-plated copper braid
ELECTROAIR®
M7-KU 01
Temperature:
- 55°C to + 150°C
Rated voltage:
600 V
Material:
ETFE
Core:
tin-plated copper
Version:
4x, 5x, 7x
ELECTROAIR®
M7BE-KU 01
Composition:
4 to 7 conductors
Temperature:
- 55°C to + 150°C
Rated voltage:
600 V
Material:
ETFE
Core:
tin-plated copper
Shielding:
tin-plated copper braid
ELECTROAIR®
AGZ 04
Temperature:
- 55°C to + 200°C
Rated voltage:
250 V
Material:
FEP
Core:
silve- plated copper
Resistance:
arc tracking
ELECTROAIR®
AGZ 05
Temperature:
- 55°C to + 200°C
Rated voltage:
600 V
Material:
FEP
Core:
silve- plated copper
Resistance:
arc tracking
ELECTROAIR®
AGZ 06
Temperature:
- 55°C to + 200°C
Rated voltage:
1000 V
Material:
FEP
Core:
silve- plated copper
Resistance:
arc tracking
ELECTROAIR®
M-AGZ 04
Temperature:
- 55°C to + 200°C
Rated voltage:
250 V
Material:
FEP
Core:
silve- plated copper
Version:
twisted (2x, 3x, 4x)
Resistance:
arc tracking
ELECTROAIR®
M-AGZ 05
Temperature:
- 55°C to + 200°C
Rated voltage:
600 V
Material:
FEP
Core:
silve- plated copper
Version:
twisted (2x, 3x, 4x)
Resistance:
arc tracking
ELECTROAIR®
M-AGZ 06
Temperature:
- 55°C to + 200°C
Rated voltage:
1000 V
Material:
FEP
Core:
silve- plated copper
Version:
twisted (2x, 3x, 4x)
Resistance:
arc tracking
ELECTROAIR®
AGZ 55, 67, 79
Temperature:
- 55°C to + 200°C
Rated voltage:
250 V
Material:
FEP
Core:
silve- plated copper
Shielding:
silver-plated copper braid
Resistance:
arc tracking
ELECTROAIR®
AGZ 57, 69, 81, 93
Temperature:
- 55°C to + 200°C
Rated voltage:
600 V
Material:
FEP
Core:
silve- plated copper
Shielding:
silver-plated copper braid
Resistance:
arc tracking
ELECTROAIR®
AGZ 59, 71, 83
Temperature:
- 55°C to + 200°C
Rated voltage:
1000 V
Material:
FEP
Core:
silve- plated copper
Shielding:
silver-plated copper braid
Resistance:
arc tracking
ELECTROAIR®
AGF 05
Temperature:
- 55°C to + 200°C
Rated voltage:
600 V
Material:
FEP
Core:
extra flexible silver-plated copper
Resistance:
arc tracking
ELECTROAIR®
M-AGF 05
Temperature:
- 55°C to + 200°C
Rated voltage:
600 V
Material:
FEP
Core:
extra flexible silver-plated copper
Version:
twisted (2x, 3x, 4x)
Resistance:
arc tracking
ELECTROAIR®
AGF 57, 69, 81, 93
Temperature:
- 55°C to + 200°C
Rated voltage:
600 V
Material:
FEP
Core:
extra flexible silver-plated copper
Shielding:
silver-plated copper braid
Resistance:
arc tracking
ELECTROAIR®
KZ 04, 07
Temperature:
- 90°C to + 200°C, + 260°C
Rated voltage:
250 V
Material:
PTFE
Core:
silver-plated or nickel-plated copper
ELECTROAIR®
KZ 05, 08
Temperature:
- 90°C to + 200°C, + 260°C
Rated voltage:
600 V
Material:
PTFE
Core:
silver-plated or nickel-plated copper
ELECTROAIR®
KZ 06, 09
Temperature:
- 90°C to + 200°C, + 260°C
Rated voltage:
1000 V
Material:
PTFE
Core:
silver-plated or nickel-plated copper
ELECTROAIR®
AH7080
Temperature:
-55°C to +150°C
Rated voltage:
600 V
Material:
Polyimide / PTFE
Core:
tin-plated copper
Resistance:
arc tracking
ELECTROAIR®
AH7083
Temperature:
- 55°C to + 150°C
Rated voltage:
600 V
Material:
Polyimide / PTFE / FEP
Core:
tin-plated copper
Shielding:
tin-plated copper spiral shield
Resistance:
arc tracking
ELECTROAIR®
FR
Temperature:
- 65°C to + 310°C
Rated voltage:
600 V
Material:
PTFE / fibre minérale
Core:
nickel-plated copper
Version:
fire resistant
ELECTROAIR®
KQ
Temperature:
- 40°C to + 85°C
Rated voltage:
100, 250, 350, 600 V
Material:
Polyurethane
Version:
improved mechanical strength
Approval:
DGA specifications
TWINLINK®
FP
Temperature:
- 55°C to + 200°C
Impedance:
50, 75, 100, 120 ohms
Material:
FEP
Core:
silve- plated copper
Shielding:
silver-plated copper braid
TWINLINK®
FA
Temperature:
- 90°C to + 260°C
Impedance:
50, 75, 100, 120 ohms
Material:
PFA
Core:
silve- plated copper
Shielding:
silver-plated copper braid
ELECTROAIR®
MIL-STD-1553 W WJC
Temperature:
- 65°C to + 200°C
Impedance:
77 ohms
Material:
fluoropolymer / polyimide
Core:
silve- plated copper
Shielding:
silver-plated copper double braid
COAXTHERM®
W5BA5 - 50
Temperature:
- 90°C to + 260°C
Impedance:
50 ohms
Material:
PFA
Size:
very small
Use:
space saving
COAXTHERM®
RG 178 BU
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
FEP
Size:
very small
Use:
space saving
COAXTHERM®
RG 178 BU / PFA
Temperature:
- 55°C to + 230°C
Impedance:
50 ohms
Material:
PFA
Size:
very small
Use:
space saving
COAXTHERM®
KX 21A
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
FEP
Size:
very small
Use:
space saving
COAXTHERM®
KX 22A
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
FEP
Size:
small
Use:
space saving
COAXTHERM®
RG 316 U
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
FEP
Size:
small
Use:
space saving
COAXTHERM®
RG 316 U / PFA
Temperature:
- 55°C to + 230°C
Impedance:
50 ohms
Material:
PFA
Size:
small
Use:
space saving
COAXTHERM®
RG 303 U
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
FEP
COAXTHERM®
RG 142 BU
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
FEP
COAXTHERM®
RG 400 U
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
FEP
COAXTHERM®
KX 23
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
PTFE / fiberglass
COAXTHERM®
RG 304 U
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
FEP
COAXTHERM®
RG 115 U
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
PTFE / fiberglass
COAXTHERM®
RG 165 U
Temperature:
- 55°C to + 250°C
Impedance:
50 ohms
Material:
PTFE / fiberglass
COAXTHERM®
RG 393 U
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
FEP
COAXTHERM®
RG 225 U
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
PTFE / fiberglass
COAXTHERM®
KX 24
Temperature:
- 55°C to + 200°C
Impedance:
50 ohms
Material:
PTFE / fiberglass
COAXTHERM®
W5BA5 - 75
Temperature:
- 90°C to + 260°C
Impedance:
75 ohms
Material:
PFA
Size:
very small
Use:
space saving
COAXTHERM®
RG 179 BU
Temperature:
- 55°C to + 200°C
Impedance:
75 ohms
Material:
FEP
Size:
small
Use:
space saving
COAXTHERM®
RG 179 BU / PFA
Temperature:
- 55°C to + 230°C
Impedance:
75 ohms
Material:
PFA
Size:
small
Use:
space saving
COAXTHERM®
RG 59 MINI HT 200C
Temperature:
-90°C to +200°C
Impedance:
75 ohms
Material:
PFA
Size:
small
Use:
space saving
COAXTHERM®
KX 25
Temperature:
- 55°C to + 200°C
Impedance:
75 ohms
Material:
PTFE / fiberglass
COAXTHERM®
RG 302 U
Temperature:
- 60°C to + 180°C
Impedance:
75 ohms
Material:
silicone
COAXTHERM®
RG 302 U
Temperature:
- 55°C to + 200°C
Impedance:
75 ohms
Material:
FEP
COAXTHERM®
RG 144 U
Temperature:
- 55°C to + 200°C
Impedance:
75 ohms
Material:
PTFE / fiberglass
COAXTHERM®
KX 8 HT 180C
Temperature:
- 60°C to + 180°C
Impedance:
75 ohms
Material:
silicone
COAXTHERM®
RG 180 BU
Temperature:
- 55°C to + 200°C
Impedance:
95 ohms
Material:
FEP
Size:
small
Use:
space saving
COAXTHERM®
RG 180 BU / PFA
Temperature:
- 55°C to + 230°C
Impedance:
95 ohms
Material:
PFA
Size:
small
Use:
space saving
CERAFIL®
CN8
Temperature:
- 90°C to + 500°C (peak + 1000°C)
Rated voltage:
150V
Material:
ceramic
Version:
innovation
Size:
miniature
COUPLIX®
K/KX-M-8, E/EX-M-8
Temperature:
- 90°C to + 500°C (peak + 1000°C)
Couple:
E, K
Material:
ceramic
Version:
thermocouple
Size:
miniature
COUPLIX®
KX-M-EE
Temperature:
- 55°C to + 260°C
Couple:
KX
Material:
Polyimide / PTFE
Version:
thermocouple, inspired of EN 2714
Size:
miniature
METALTRESSE®
GTCA
Temperature:
- 60°C to + 200°C
Material:
silver plated copper
Version:
1.5 and 2 µm guaranteed thickness
METALTRESSE®
GTCN
Temperature:
- 60°C to + 250°C
Material:
nickel plated copper
Version:
1.27 µm guaranteed thickness
MINOROC®
P
Temperature:
- 40°C to + 80°C
Traction:
150 to 3 500 daN
Material:
thermoplastic
Core:
synthetic polyester fibres
MINOROC®
K
Temperature:
- 40°C to + 80°C
Traction:
1060 to 6000 daN
Material:
thermoplastic
Core:
synthetic aramide fibres
OMBILIFLEX®
Special multi-function cables
Composition:
umbilical cable
Version:
customized product
Specific:
multi-function ernergy, signal, fluid, traction...
SPIRFLEX®
High performance spiral cables
Composition:
spiral cables
Version:
customized product
Specific:
fitted with or without connectors
POWER CONNECT®
Power cords
Composition:
cables with crimped lugs
Version:
customized product
PLASTHERM®
E40-FR, M-E40-FR
Temperature:
- 40°C to + 150°C
Rated voltage:
600 V
Material:
halogen free
Core:
tin-plated copper
PLASTHERM®
M40BE-E40-FR
Temperature:
- 40°C to + 150°C
Rated voltage:
600 V
Material:
halogen free
Core:
tin-plated copper
Shielding:
tin-plated copper braid
HIFLEX®
CH2 POWER
Composition:
single-core
Temperature:
- 20°C to + 90°C
Rated voltage:
1000 V
Material:
extra flexible PVC
Core:
flexible bare copper, class 5
Specific:
2 million cycles in cable carrier chains
HIFLEX®
CH5 POWER
Composition:
single-core
Temperature:
- 20°C to + 90°C
Rated voltage:
1000 V
Material:
polyurethane
Core:
flexible bare copper, class 5
Version:
halogen free
Specific:
5 million cycles in cable carrier chains
HIFLEX®
CH5 BE POWER
Composition:
single-core
Temperature:
- 20°C to + 90°C
Rated voltage:
1000 V
Material:
polyurethane
Core:
flexible bare copper, class 5
Shielding:
tin-plated copper braid
Version:
halogen free
Specific:
5 million cycles in cable carrier chains
HIFLEX®
CH2 CONTROL
Composition:
multi-core
Temperature:
- 20°C to + 90°C
Rated voltage:
500 V
Material:
extra flexible PVC
Core:
extra flexible bare copper, class 6
Specific:
2 million cycles in cable carrier chains
HIFLEX®
CH5 CONTROL
Composition:
multi-core
Temperature:
- 20°C to + 90°C
Rated voltage:
500 V
Material:
polyurethane
Core:
extra flexible bare copper, class 6
Version:
halogen free
Specific:
5 million cycles in cable carrier chains
HIFLEX®
CH5 BE CONTROL
Composition:
multi-core
Temperature:
- 20°C to + 90°C
Rated voltage:
500 V
Material:
polyurethane
Core:
extra flexible bare copper, class 6
Shielding:
tin-plated copper braid
Version:
halogen free
Specific:
5 million cycles in cable carrier chains
HIFLEX®
FX5 CONTROL
Composition:
multi-core
Temperature:
- 20°C to + 90°C
Rated voltage:
500 V
Material:
polyurethane
Core:
extra flexible bare copper, class 6
Version:
halogen free
Specific:
5 million cycles in alternate bending
HIFLEX®
TF5 CONTROL
Composition:
multi-core
Temperature:
- 20°C to + 90°C
Rated voltage:
500 V
Material:
polyurethane
Core:
extra flexible bare copper, class 6
Specific:
5 million cycles in flexion and torsion
HIFLEX®
TF5 BE CONTROL
Composition:
multi-core
Temperature:
- 20°C to + 90°C
Rated voltage:
500 V
Material:
polyurethane
Core:
extra flexible bare copper, class 6
Shielding:
tin-plated copper spiral shield
Specific:
5 million cycles in flexion and torsion
SILICOUL®
1.1 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
Lloyd's register & BV
SILICOUL®
3.7 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
Lloyd's register
SILICOUL®
6.6 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
Lloyd's register
SILICOUL®
13.8 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
Lloyd's register
SILICOUL®
Style 3661
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
UL
SILICOUL®
Style 3662
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
UL
SILICOUL®
Style 3663
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
UL
SILICOUL®
Style 3664
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
UL
SILICOUL®
ALU FLEX 1.1 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Version:
with aluminium core
SILICOUL®
ALU FLEX 3.7 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Version:
with aluminium core
SILICOUL®
ALU FLEX 6.6 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Version:
with aluminium core
SILICOUL®
ALU FLEX 13.8 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Version:
with aluminium core
SILICOUL®
SCR 1.1 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Version:
tin-plated copper braid
SILICOUL®
SCR 3.7 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Version:
tin-plated copper braid
SILICOUL®
SCR 6.6 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Version:
tin-plated copper braid
SILICOUL®
SCR 13.8 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Version:
tin-plated copper braid
SILICOUL®
DI 1.1 KV
Temperature:
- 60°C to + 180°C
Material:
silicone
Version:
double insulation
SILICOUL®
DI 3.7 KV
Temperature:
- 60°C to + 180°C
Material:
silicone
Version:
double insulation
SILICOUL®
DI 6.6 KV
Temperature:
- 60°C to + 180°C
Material:
silicone
Version:
double insulation
SILICOUL®
DI 13.8 KV
Temperature:
- 60°C to + 180°C
Material:
silicone
Version:
double insulation
SILICOUL®
DI Style 3661 - 1.1 KV
Temperature:
- 60°C to + 180°C
Material:
silicone
Version:
double insulation
Approval:
UL
SILICOUL®
DI Style 3662 - 4.2 KV
Temperature:
- 60°C to + 180°C
Material:
silicone
Version:
double insulation
Approval:
UL
SILICOUL®
DI Style 3663 - 7.2 KV
Temperature:
- 60°C to + 180°C
Material:
silicone
Version:
double insulation
Approval:
UL
SILICOUL®
DI Style 3664 - 15 KV
Temperature:
- 60°C to + 180°C
Material:
silicone
Version:
double insulation
Approval:
UL
SILICOUL®
ST PUR 1.1 KV
Temperature:
- 40°C to + 150°C
Material:
silicone / Polyurethane
Version:
double insulation
Resistance:
hydrocarbons
SILICOUL®
ST PUR 3.7 KV
Temperature:
- 40°C to + 150°C
Material:
silicone / Polyurethane
Version:
double insulation
Resistance:
hydrocarbons
SILICOUL®
ST PUR 6.6 KV
Temperature:
- 40°C to + 150°C
Material:
silicone / Polyurethane
Version:
double insulation
Resistance:
hydrocarbons
SILICOUL®
ST PUR 13.8 KV
Temperature:
- 40°C to + 150°C
Material:
silicone / Polyurethane
Version:
double insulation
Resistance:
hydrocarbons
SILICOUL®
SCR PUR 1.1 KV
Temperature:
- 40°C to + 150°C
Material:
silicone with reinforcing braid / PU
Version:
tin-plated copper braid
Resistance:
hydrocarbons
SILICOUL®
SCR PUR 3.7 KV
Temperature:
- 40°C to + 150°C
Material:
silicone with reinforcing braid / PU
Version:
tin-plated copper braid
Resistance:
hydrocarbons
SILICOUL®
SCR PUR 6.6 KV
Temperature:
- 40°C to + 150°C
Material:
silicone with reinforcing braid / PU
Version:
tin-plated copper braid
Resistance:
hydrocarbons
SILICOUL®
SCR PUR 13.8 KV
Temperature:
- 40°C to + 150°C
Material:
silicone with reinforcing braid / PU
Version:
tin-plated copper braid
Resistance:
hydrocarbons
PLASTHERM®
FLRY
Temperature:
- 40°C to + 105°C
Material:
PVC 105°C
Core:
ISO 6722-1, ISO 19642-3 type A : FLRY-A & type B : FLRY-B
Specific:
ISO 19642-3
PLASTHERM®
FLRYW
Temperature:
- 40°C to + 125°C
Material:
PVC 125°C
Core:
ISO 6722-1, ISO 19642-3 type A : FLRYW-A & type B : FLRYW-B
Specific:
ISO 19642-3
PLASTHERM®
FLR11Y
Temperature:
- 40°C to + 150°C
Material:
TPE-U
Core:
ISO 6722-1, ISO 19642-3 type A : FLR11Y-A & type B : FLR11Y-B
Specific:
ISO 19642-3
SILIFLON®
FLR7Y
Temperature:
- 40°C to + 175°C
Material:
ETFE
Core:
ISO 6722-1, ISO 19642-3 type A : FLR7Y-A & type B : FLR7Y-B
Specific:
ISO 19642-3
SILIFLON®
FLR6Y
Temperature:
- 40°C to + 210°C
Material:
FEP
Core:
ISO 6722-1, ISO 19642-3 type A : FLR6Y-A & type B : FLR6Y-B
Specific:
ISO 19642-3
SILIFLON®
FLR51Y
Temperature:
- 40°C to + 260°C
Material:
PFA
Core:
ISO 6722-1, ISO 19642-3 type A : FLR51Y-A & type B : FLR51Y-B
Specific:
ISO 19642-3
SILICABLE®
FL2G
Temperature:
- 40°C to + 200°C
Material:
silicone
Core:
ISO 6722-1, ISO 19642-3 type B : FL2G-B & type C : FL2G-C
Specific:
ISO 19642-3
PLASTHERM®
FLR2X
Temperature:
- 40°C to + 125°C
Material:
PE-X
Core:
ISO 6722-1, ISO 19642-3 type A : FLR2X-A & type B : FLR2X-B
Version:
Halogen free
Specific:
ISO 19642-3
PLASTHERM®
FLR41X
Temperature:
- 40°C to + 150°C
Material:
PO-X
Core:
ISO 6722-1, ISO 19642-3 type A : FLR41X-A & type B : FLR41X-B
Version:
Halogen free
Specific:
ISO 19642-3
PLASTHERM®
FLR41X
Temperature:
- 40°C to + 150°C
Material:
PO-X
Core:
ISO 6722-1, ISO 19642-3 type A : FLR41X-A & type B : FLR41X-B
Version:
Halogen free
Specific:
ISO 19642-3
SILICABLE®
FHL2G-C
Temperature:
- 40°C to + 180°C, Class E
Rated voltage:
1000 VAC / 1500 VDC
Material:
silicone
Core:
ISO 6722-1, ISO 19642-5 & EN 13602
Version:
Halogen free
Specific:
ISO 19642-5
SILICABLE®
FHLR2GCB2G-C Mono
Temperature:
- 40°C to + 180°C, Class E
Rated voltage:
1000 VAC / 1500 VDC
Material:
silicone
Core:
ISO 6722-1, ISO 19642-5 & EN 13602
Shielding:
double shielding, single core version
Version:
Halogen free
Specific:
ISO 19642-9
SILICABLE®
FHLR2GCB2G-C Multi
Temperature:
- 40°C to + 180°C, Class E
Rated voltage:
600 VAC / 900 VDC (cross sections < 10 mm²), 1000 VAC / 1500 VDC (cross sections > 6 mm²)
Material:
silicone
Core:
ISO 6722-1, ISO 19642-5 & EN 13602
Shielding:
double shielding, single core version
Version:
Halogen free
Specific:
ISO 19642-9
SILICABLE®
FHLR6YBCF2G Hybride
Temperature:
- 40°C to + 180°C, Class E
Rated voltage:
600 VAC / 900 VDC
Material:
silicone
Core:
ISO 6722-1, ISO 19642-5
Shielding:
double shielding + twisted shielded pair 2x0.5 mm²
Version:
Specific composition 2x4 + 0.5 mm²
Specific:
ISO 19642-9
SILICABLE®
FHLR2G-C
Temperature:
- 40°C to + 180°C, Class E
Rated voltage:
600 VAC / 900 VDC (cross sections < 10 mm²), 1000 VAC / 1500 VDC (cross sections > 6 mm²)
Material:
silicone
Core:
ISO 6722-1, ISO 19642-5 & EN 13602
Version:
Halogen free
Specific:
ISO 19642-5
SILICABLE®
FHLR2G LV216
Temperature:
- 40°C to + 180°C, Class E
Rated voltage:
600 VAC / 1000 VDC
Material:
silicone
Core:
ISO 6722-1 & EN 13602
Version:
Halogen free
Specific:
LV 216 - 2
SILICABLE®
FHLR2GCB2G LV216 Mono
Temperature:
- 40°C to + 180°C, Class E
Rated voltage:
600 VAC / 900 VDC (cross sections < 10 mm²), 1000 VAC / 1500 VDC (cross sections > 6 mm²)
Material:
silicone
Core:
ISO 6722-1 & EN 13602
Shielding:
double shielding, single core version
Version:
Halogen free
Specific:
LV 216 - 2
SILICABLE®
FHLR2G2G-C Multi
Temperature:
- 40°C to + 180°C, Class E
Rated voltage:
600 VAC / 900 VDC (cross sections < 10 mm²), 1000 VAC / 1500 VDC (cross sections > 6 mm²)
Material:
silicone
Core:
ISO 6722-1, ISO 19642-5 & EN 13602
Version:
Halogen free
Specific:
ISO 19642-9
SILICABLE®
FHLR2GCB2G LV216 Multi
Temperature:
- 40°C to + 180°C, Class E
Rated voltage:
600 VAC / 1000 VDC
Material:
silicone
Core:
ISO 6722-1, LV 216-2 & EN 13602
Shielding:
double shielding, multicore version
Version:
Halogen free
Specific:
LV 216 - 2
FLEXBAT®
ST
Temperature:
- 15°C to + 70°C
Rated voltage:
450/750 V
Material:
extra flexible PVC
Core:
IEC 60228, extra flexible
FLEXBAT®
HT
Temperature:
- 25°C to + 105°C
Rated voltage:
450/750 V
Material:
extra flexible PVC
Core:
IEC 60228, extra flexible
FLEXBAT®
THT
Temperature:
- 25°C to + 125°C
Rated voltage:
450/750 V
Material:
TPE 125°C
Core:
IEC 60228, extra flexible
FLEXBAT®
DI LR HT
Temperature:
- 40°C to + 105°C
Rated voltage:
600/600 V
Material:
extra flexible PVC
Core:
ISO 6722 type B & C
Version:
double insulation
TWINBAT®
RN
Temperature:
- 15°C to + 70°C
Rated voltage:
450/750 V
Material:
extra flexible PVC
Core:
IEC 60228, extra flexible
Version:
2-conductor
SILICABLE®
Style 5400
Temperature:
- 60°C to + 550°C
Rated voltage:
600 V
Material:
composites
Core:
nickel-plated copper or nickel
Approval:
UL
SILICABLE®
Style 5390
Temperature:
- 60°C to + 550°C
Rated voltage:
300 V
Material:
composites
Core:
nickel-plated copper or nickel
Approval:
UL
TS LAN®
Cat 6A SF/UTP LSZH
Temperature:
- 20°C to + 70°C
Impedance:
100 ohms
Material:
halogen free
Version:
screened and shielded
PRODUCTS
SPECIFICATIONS
SILICABLE®
MC-ECS
Temperature:
- 60°C to + 180°C
Rated voltage:
600/1000 V
Material:
silicone
SILICABLE®
MCBE-ECS
Temperature:
- 60°C to + 180°C
Rated voltage:
600/1000 V
Material:
silicone
Shielding:
tin-plated copper braid
SILICABLE®
MCBAL-ECS
Temperature:
- 60°C to + 180°C
Rated voltage:
600/1000 V
Material:
silicone
Version:
screened
SILICABLE®
MC-HRD
Temperature:
- 60°C to + 180°C
Rated voltage:
600/1000 V
Material:
silicone
Version:
improved mechanical strength
SILICABLE®
MCBE-HRD
Temperature:
- 60°C to + 180°C
Rated voltage:
600/1000 V
Material:
silicone
Shielding:
tin-plated copper braid
Version:
improved mechanical strength
SILICABLE®
H05SS-F
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V
Material:
silicone
Version:
<HAR>
SILICABLE®
H05SS-F HRD
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V
Material:
silicone
Version:
improved mechanical strength
Version:
<HAR>
SILICABLE®
MC-EFEP
Temperature:
- 60°C to + 200°C
Rated voltage:
300/500 V
Material:
silicone (fluoropolymer insulation)
SILICABLE®
MCBE-EFEP
Temperature:
- 60°C to + 200°C
Rated voltage:
300/500 V
Material:
silicone (fluoropolymer insulation)
Shielding:
tin-plated copper braid
SILICABLE®
Style 4389-S150
Temperature:
- 60°C to + 150°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 4389-S150 VW-1
Temperature:
- 60°C to + 150°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 4476-S150
Temperature:
- 60°C to + 150°C
Rated voltage:
300, 600, 1000 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 4389-S200
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 4389-S200 VW-1
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 4476-S200
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 4421-S200
Temperature:
- 60°C to + 200°C
Rated voltage:
300, 600, 1000 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 4476-E150
Temperature:
- 60°C to + 150°C
Rated voltage:
300, 600 V
Material:
silicone (fluoropolymer insulation)
Approval:
UL
SILICABLE®
Style 4389-E150
Temperature:
- 60°C to + 150°C
Rated voltage:
600, 1000 V
Material:
silicone (fluoropolymer insulation)
Approval:
UL
SILICABLE®
Style 4389-E150 VW-1
Temperature:
- 60°C to + 150°C
Rated voltage:
600, 1000 V
Material:
silicone (fluoropolymer insulation)
Approval:
UL
SILICABLE®
Style 4476-F200
Temperature:
- 60°C to + 200°C
Rated voltage:
300, 600 V
Material:
silicone (fluoropolymer insulation)
Approval:
UL
SILICABLE®
Style 4389-F200
Temperature:
- 60°C to + 200°C
Rated voltage:
600, 1000 V
Material:
silicone (fluoropolymer insulation)
Approval:
UL
SILICABLE®
Style 4389-F200 VW-1
Temperature:
- 60°C to + 200°C
Rated voltage:
600, 1000 V
Material:
silicone (fluoropolymer insulation)
Approval:
UL
SILISOL®
SIHF-TBT
Temperature:
- 60°C to + 180°C
Rated voltage:
500 V
Material:
silicone
SILICABLE®
VMC-ECS
Temperature:
- 60°C to + 180°C
Rated voltage:
600/1000 V
Material:
silicone with reinforcing braid
SILICABLE®
PMC-ECS
Temperature:
- 60°C to + 180°C
Rated voltage:
600/1000 V
Material:
silicone with reinforcing braid
SILICABLE®
H05SST-F
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V
Material:
silicone with reinforcing braid
Approval:
<HAR>
VARPREN®
MVA
Temperature:
- 30°C to + 150°C
Rated voltage:
450/750 V
Material:
Varpren®
VARPREN®
H05GG-F
Temperature:
- 15°C to + 110°C
Rated voltage:
300/500 V
Material:
Varpren®
Version:
halogen free
Approval:
<HAR>
SILIFLON®
M6-E6
Temperature:
- 90°C to + 205°C
Rated voltage:
300/500 V
Material:
fluoropolymer
SILIFLON®
M6BE-E6
Temperature:
- 90°C to + 205°C
Rated voltage:
300/500 V
Material:
fluoropolymer
Shielding:
tin-plated copper braid
SILIFLON®
Style 20221-E150
Temperature:
- 90°C to + 150°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 20905-E150
Temperature:
- 90°C to + 150°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 20222-E150
Temperature:
- 90°C to + 150°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 20711-F200
Temperature:
- 90°C to + 200°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 2749-F200
Temperature:
- 90°C to + 200°C
Rated voltage:
300 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 20710-F200
Temperature:
- 90°C to + 200°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 2750-F200
Temperature:
- 90°C to + 200°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
PLASTHERM®
MY2-Y2, MY2-EY2
Temperature:
- 30°C to + 105°C
Rated voltage:
600/1000 V
Material:
thermoplastic PVC
PLASTHERM®
Style 2464-Y80
Temperature:
- 30°C to + 80°C
Rated voltage:
300 V
Material:
thermoplastic PVC
Approval:
UL
PLASTHERM®
Style 2570-Y80
Temperature:
- 30°C to + 80°C
Rated voltage:
600 V
Material:
thermoplastic PVC
Approval:
UL
PLASTHERM®
Style 2654-Y90
Temperature:
- 30°C to + 90°C
Rated voltage:
300 V
Material:
thermoplastic PVC
Approval:
UL
PLASTHERM®
Style 2587-Y90
Temperature:
- 30°C to + 90°C
Rated voltage:
600 V
Material:
thermoplastic PVC
Approval:
UL
PLASTHERM®
Style 2517-Y105
Temperature:
- 30°C to + 105°C
Rated voltage:
300 V
Material:
thermoplastic PVC
Approval:
UL
PLASTHERM®
Style 2586-Y105
Temperature:
- 30°C to + 105°C
Rated voltage:
1000 V
Material:
thermoplastic PVC
Approval:
UL
PRODUCTS
SPECIFICATIONS
SILICABLE®
CS-HT
Temperature:
- 60°C to + 180°C
Rated voltage:
15 to 30 kV
Material:
silicone
SILICABLE®
CSV-HT
Temperature:
- 60°C to + 180°C
Rated voltage:
15 to 30 kV
Material:
silicone with reinforcing braid
SILICABLE®
CSVCS-HT
Temperature:
- 60°C to + 180°C
Rated voltage:
15 to 30 kV
Material:
silicone with reinforcing braid
SILICABLE®
ECS-HT VDE
Temperature:
- 60°C to + 180°C
Rated voltage:
10 kV
Material:
silicone
SILICABLE®
Style 3304
Temperature:
- 60°C to + 200°C
Rated voltage:
10 kV AC
Material:
silicone with reinforcing braid
Approval:
UL
SILICABLE®
Style 3573
Temperature:
- 60°C to + 200°C
Rated voltage:
10 kV AC
Material:
silicone with reinforcing braid
Approval:
UL
SILICABLE®
Style 10185-E150
Temperature:
- 90°C to + 150°C
Rated voltage:
10 kV AC
Material:
fluoropolymer
Approval:
UL
SILICABLE®
Style 1911-F150
Temperature:
- 90°C to + 150°C
Rated voltage:
20 kV DC
Material:
fluoropolymer
Approval:
UL
SILICABLE®
Style 1813
Temperature:
- 90°C to + 200°C
Rated voltage:
3000 V (cUL 1000 V)
Material:
fluoropolymer
Approval:
UL
SILICABLE®
Style 10185-E200
Temperature:
- 90°C to + 200°C
Rated voltage:
10 kV AC
Material:
fluoropolymer
Approval:
UL
SILICABLE®
Style 1911-F250
Temperature:
- 90°C to + 250°C
Rated voltage:
20 kV DC
Material:
fluoropolymer
Approval:
UL
PRODUCTS
SPECIFICATIONS

Electrical Technology and Engineering

Low-voltage wires, Flexible medium-voltage 1.1 to 15 kV cables, Braided insulated sleeving, Certified UL, CSA, HAR, VDE, Lloyd's register, Bureau Veritas

The OMERIN Group is an established name in the Electrical Technology and Engineering sector (cabling for transformers, selfs, inverters, current converters and power supply cabinets). Our cable ranges PLASTHERM® (thermoplastic-insulated wires and cables), SILICABLE® (silicone-insulated wires and cables with or without reinforcing braid), VARPREN® (Varpren® elastomer-insulated wires and cables), SILIFLON® (fluoropolymer-insulated wires and cables with or without reinforcing braid), SILICOUL® (flexible medium-voltage cables) and SILIGAINE® high-temperature braided sleevings offer an excellent response to the vast majority of special market needs. Our products comply with the primary international standards and certifications: UL, CSA, HAR, VDE, Lloyd’s register, Bureau Veritas to guarantee top-notch reliability and quality. In addition to this offer, the OMERIN Group manufactures extruded insulating sleevings and power cords fitted with crimped lugs.

PRODUCTS
SPECIFICATIONS
VARPREN®
125
Temperature:
- 50°C to + 125°C
Rated voltage:
450/750 V, 600/1000 V
Material:
Varpren®
VARPREN®
155
Temperature:
- 50°C to + 155°C
Rated voltage:
450/750 V, 600/1000 V
Material:
Varpren®
VARPREN®
MAX
Temperature:
- 30°C to 125°C
Rated voltage:
600/1000 V
Material:
Varpren®
PRODUCTS
SPECIFICATIONS
SILIFLON®
Style 10935
Temperature:
- 60°C to + 150°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
SILIFLON®
Style 11881
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
fluoropolymer
Approval:
UL
PRODUCTS
SPECIFICATIONS
PROFIPLAST®
H07V-K
Temperature:
- 5°C to + 70°C
Rated voltage:
450/750 V
Material:
PVC
Approval:
RPC EN 50575, <HAR>
PROFIPLAST®
H07V2-K
Temperature:
- 5°C to + 90°C
Rated voltage:
450/750 V
Material:
PVC
Approval:
RPC EN 50575, <HAR>
PROFIPLAST®
07Z1-K
Temperature:
- 5°C to + 70°C
Rated voltage:
450/750 V
Material:
halogen free
PROFIPLAST®
10V2-K
Temperature:
- 25°C to + 105°C
Rated voltage:
600/1000 V
Material:
PVC 105°C
PROFIPLAST®
10Z1-K
Temperature:
- 25°C to + 105°C
Rated voltage:
600/1000 V
Material:
halogen free
PRODUCTS
SPECIFICATIONS
SILICOUL®
1.1 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
Lloyd's register & BV
SILICOUL®
3.7 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
Lloyd's register
SILICOUL®
6.6 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
Lloyd's register
SILICOUL®
13.8 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
Lloyd's register
SILICOUL®
Style 3661
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
UL
SILICOUL®
Style 3662
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
UL
SILICOUL®
Style 3663
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
UL
SILICOUL®
Style 3664
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
UL
SILICOUL®
ALU FLEX 1.1 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Version:
with aluminium core
SILICOUL®
ALU FLEX 3.7 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Version:
with aluminium core
SILICOUL®
ALU FLEX 6.6 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Version:
with aluminium core
SILICOUL®
ALU FLEX 13.8 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Version:
with aluminium core
SILICOUL®
SCR 1.1 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Shielding:
tin-plated copper braid
SILICOUL®
SCR 3.7 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Shielding:
tin-plated copper braid
SILICOUL®
SCR 6.6 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Shielding:
tin-plated copper braid
SILICOUL®
SCR 13.8 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Shielding:
tin-plated copper braid
SILICOUL®
DI 1.1 KV
Temperature:
- 60°C to + 180°C
Material:
silicone
Version:
double insulation
SILICOUL®
DI 3.7 KV
Temperature:
- 60°C to + 180°C
Material:
silicone
Version:
double insulation
SILICOUL®
DI 6.6 KV
Temperature:
- 60°C to + 180°C
Material:
silicone
Version:
double insulation
SILICOUL®
DI 13.8 KV
Temperature:
- 60°C to + 180°C
Material:
silicone
Version:
double insulation
SILICOUL®
DI Style 3661 - 1.1 KV
Temperature:
- 60°C to + 180°C
Material:
silicone
Version:
double insulation
Approval:
UL
SILICOUL®
DI Style 3662 - 4.2 KV
Temperature:
- 60°C to + 180°C
Material:
silicone
Version:
double insulation
Approval:
UL
SILICOUL®
DI Style 3663 - 7.2 KV
Temperature:
- 60°C to + 180°C
Material:
silicone
Version:
double insulation
Approval:
UL
SILICOUL®
DI Style 3664 - 15 KV
Temperature:
- 60°C to + 180°C
Material:
silicone
Version:
double insulation
Approval:
UL
SILICOUL®
ST PUR 1.1 KV
Temperature:
- 40°C to + 150°C
Material:
silicone / Polyurethane
Version:
double insulation
Resistance:
hydrocarbons
SILICOUL®
ST PUR 3.7 KV
Temperature:
- 40°C to + 150°C
Material:
silicone / Polyurethane
Version:
double insulation
Resistance:
hydrocarbons
SILICOUL®
ST PUR 6.6 KV
Temperature:
- 40°C to + 150°C
Material:
silicone / Polyurethane
Version:
double insulation
Resistance:
hydrocarbons
SILICOUL®
ST PUR 13.8 KV
Temperature:
- 40°C to + 150°C
Material:
silicone / Polyurethane
Version:
double insulation
Resistance:
hydrocarbons
SILICOUL®
SCR PUR 1.1 KV
Temperature:
- 40°C to + 150°C
Material:
silicone with reinforcing braid / PU
Shielding:
tin-plated copper braid
Resistance:
hydrocarbons
SILICOUL®
SCR PUR 3.7 KV
Temperature:
- 40°C to + 150°C
Material:
silicone with reinforcing braid / PU
Shielding:
tin-plated copper braid
Resistance:
hydrocarbons
SILICOUL®
SCR PUR 6.6 KV
Temperature:
- 40°C to + 150°C
Material:
silicone with reinforcing braid / PU
Shielding:
tin-plated copper braid
Resistance:
hydrocarbons
SILICOUL®
SCR PUR 13.8 KV
Temperature:
- 40°C to + 150°C
Material:
silicone with reinforcing braid / PU
Shielding:
tin-plated copper braid
Resistance:
hydrocarbons
PRODUCTS
SPECIFICATIONS
SILIGAINE®
15C1.5
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
1.5 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C2
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
2.5 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C3
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 3 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C3-UV
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 3 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C4
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 4 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C4.d
Temperature:
- 60°C to + 200°C, Class H
Dielectric strength:
> 4 kV (dry)
Material:
fiberglass (double insulation)
Version:
abrasion resistance
SILIGAINE®
15C5
Temperature:
- 60°C to + 200°C, Class H
Dielectric strength:
> 4 kV (dry)
Material:
fiberglass (double insulation)
Version:
abrasion resistance
SILIGAINE®
15C5
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 5 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C5-E EXTENSIBLE
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 5 kV (dry)
Material:
fiberglass with silicone coating
Version:
expandable
SILIGAINE®
15C7 GRADE A UL
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 7 kV (dry)
Material:
fiberglass with silicone coating
Approval:
UL
SILIGAINE®
15C10
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 10 kV (dry)
Material:
fiberglass with silicone coating
PRODUCTS
SPECIFICATIONS
SILIGAINE®
13F1
Temperature:
- 30°C to + 155°C, Class F
Dielectric strength:
> 1 kV (dry)
Material:
fiberglass with PU coating
SILIGAINE®
13F3
Temperature:
- 30°C to + 155°C, Class F
Dielectric strength:
3 kV (dry, central value)
Material:
fiberglass with PU coating
SILIGAINE®
13F4
Temperature:
- 30°C to + 155°C, Class F
Dielectric strength:
> 4 kV (dry)
Material:
fiberglass with PU coating
SILIGAINE®
16F2
Temperature:
- 30°C to + 155°C, Class F
Dielectric strength:
1.8 kV (dry, central value)
Material:
fiberglass with acrylic coating
SILIGAINE®
16F3
Temperature:
- 30°C to + 155°C, Class F
Dielectric strength:
3.3 kV (dry, central value)
Material:
fiberglass with acrylic coating
SILIGAINE®
16F7 UL
Temperature:
- 30°C to + 155°C, Class F
Dielectric strength:
7 kV (dry, central value)
Material:
fiberglass with acrylic coating
Approval:
UL

Rail Industry

Power cables, Data cables, Insulated sleevings, Electrical heat tracing systems, Traction cables...

The OMERIN Group is IRIS certified and is a recognised specialist in the Rolling Stock sector. We design and manufacture a wide range of insulated sleevings and cables, braided or extruded, which have been certified to European Rail Industry standards. All our products offer upgraded fire / smoke characteristics in accordance with the requirements of standard EN 45545-2 to guarantee top-notch safety and reliability. We also develop solutions for the Railway Infrastructures sector: electrical heat tracing systems for railways and traction cables for catenary systems.

PRODUCTS
SPECIFICATIONS
VARPREN® RW
EN 50306-2 300V M
Temperature:
- 40°C to + 105°C
Rated voltage:
300/500 V
Material:
Varpren®
VARPREN® RW
EN 50306-3 300V MM S
Temperature:
- 40°C to + 105°C
Rated voltage:
300/500 V
Material:
Varpren®
Shielding:
tin-plated copper braid
VARPREN® RW
EN 50306-4 300V MM 1E 1P
Temperature:
- 40°C to + 90°C
Rated voltage:
300/500 V
Material:
Varpren®
VARPREN® RW
EN 50306-4 300V MM S 3E 3P
Temperature:
- 40°C to + 90°C
Rated voltage:
300/500 V
Material:
Varpren®
Shielding:
tin-plated copper braid
VARPREN® RW
EN 50306-4 300V MMM S 5E 5P
Temperature:
- 40°C to + 90°C
Rated voltage:
300/500 V
Material:
Varpren®
Shielding:
tin-plated copper braid (individual)
Version:
twisted pairs
VARPREN® RW
EN 50306-4 300V MM S 7E 7P
Temperature:
- 40°C to + 90°C
Rated voltage:
300/500 V
Material:
Varpren®
Shielding:
tin-plated copper braid (general)
Version:
twisted pairs
PRODUCTS
SPECIFICATIONS
SILICABLE® RW
EN 50382-2 1800V F 120°C
Temperature:
- 40°C to + 120°C
Rated voltage:
1.8 /3 kV
Material:
silicone
SILICABLE® RW
EN 50382-2 1800V F 150°C
Temperature:
- 40°C to + 150°C
Rated voltage:
1.8 /3 kV
Material:
silicone
SILICABLE® RW
EN 50382-2 3600V F 120°C
Temperature:
- 40°C to + 120°C
Rated voltage:
3.6 /6 kV
Material:
silicone
SILICABLE® RW
EN 50382-2 3600V F 150°C
Temperature:
- 40°C to + 150°C
Rated voltage:
3.6 /6 kV
Material:
silicone
SILICABLE® RW
EN 50382-2 1800V FF 120°C
Temperature:
- 40°C to + 120°C
Rated voltage:
1.8 /3 kV
Material:
silicone
SILICABLE® RW
EN 50382-2 1800V FF 150°C
Temperature:
- 40°C to + 150°C
Rated voltage:
1.8 /3 kV
Material:
silicone
SILICABLE® RW
EN 50382-2 3600V FF 120°C
Temperature:
- 40°C to + 120°C
Rated voltage:
3.6 /6 kV
Material:
silicone
SILICABLE® RW
EN 50382-2 3600V FF 150°C
Temperature:
- 40°C to + 150°C
Rated voltage:
3.6 /6 kV
Material:
silicone
SILICABLE® RW
EN 50382-2 3600V FXZ 120°C
Temperature:
- 40°C to + 120°C
Rated voltage:
3.6 /6 kV
Material:
silicone
SILICABLE® RW
EN 50382-2 3600V FXZ 150°C
Temperature:
- 40°C to + 150°C
Rated voltage:
3.6 /6 kV
Material:
silicone
SILICABLE® RW
EN 50382-2 1800V FF S 120°C
Temperature:
- 40°C to + 120°C
Rated voltage:
1.8 /3 kV
Material:
silicone
Shielding:
tin-plated copper braid
SILICABLE® RW
EN 50382-2 3600V FF S 120°C
Temperature:
- 40°C to + 120°C
Rated voltage:
3.6 /6 kV
Material:
silicone
Shielding:
tin-plated copper braid
SILICABLE® RW
EN 50382-2 3600V FFXZ S 120°C
Temperature:
- 40°C to + 120°C
Rated voltage:
3.6 /6 kV
Material:
silicone
Shielding:
tin-plated copper braid
PRODUCTS
SPECIFICATIONS
VARPREN® RW
EN 50264-2-1 600V M
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
VARPREN® RW
EN 50264-2-1 1800V M
Temperature:
- 40°C to + 90°C
Rated voltage:
1.8 /3 kV
Material:
Varpren®
VARPREN® RW
EN 50264-2-1 1800V MM
Temperature:
- 40°C to + 90°C
Rated voltage:
1.8 /3 kV
Material:
Varpren®
VARPREN® RW
EN 50264-2-1 3600V MM
Temperature:
- 40°C to + 90°C
Rated voltage:
3.6 /6 kV
Material:
Varpren®
VARPREN® RW
EN 50264-2-2 300V MM
Temperature:
- 40°C to + 90°C
Rated voltage:
300/500 V
Material:
Varpren®
VARPREN® RW
EN 50264-2-2 600V MM
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
VARPREN® RW
EN 50264-2-2 300V MM S
Temperature:
- 40°C to + 90°C
Rated voltage:
300/500 V
Material:
Varpren®
Shielding:
tin-plated copper braid
VARPREN® RW
EN 50264-2-2 600V MM S
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
Shielding:
tin-plated copper braid
VARPREN® RW
EN 50264-2-1 600V MM S
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
Shielding:
tin-plated copper braid
VARPREN® RW
EN 50264-2-1 1800V MM S
Temperature:
- 40°C to + 90°C
Rated voltage:
1.8 /3 kV
Material:
Varpren®
Shielding:
tin-plated copper braid
VARPREN® RW
EN 50264-2-1 3600V MM S
Temperature:
- 40°C to + 90°C
Rated voltage:
3.6 /6 kV
Material:
Varpren®
Shielding:
tin-plated copper braid
VARPREN® RW
EN 50264-3-1 600V M
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
VARPREN® RW
EN 50264-3-1 1800V M
Temperature:
- 40°C to + 90°C
Rated voltage:
1.8 /3 kV
Material:
Varpren®
VARPREN® RW
EN 50264-3-1 1800V MM
Temperature:
- 40°C to + 90°C
Rated voltage:
1.8 /3 kV
Material:
Varpren®
VARPREN® RW
EN 50264-3-1 3600V MM
Temperature:
- 40°C to + 90°C
Rated voltage:
3.6 /6 kV
Material:
Varpren®
VARPREN® RW
EN 50264-3-2 300V MM
Temperature:
- 40°C to + 90°C
Rated voltage:
300/500 V
Material:
Varpren®
VARPREN® RW
EN 50264-3-2 600V MM
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
VARPREN® RW
EN 50264-3-2 300V MM S
Temperature:
- 40°C to + 90°C
Rated voltage:
300/500 V
Material:
Varpren®
Shielding:
tin-plated copper braid
VARPREN® RW
EN 50264-3-2 600V MM S
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
Shielding:
tin-plated copper braid
PRODUCTS
SPECIFICATIONS
VARPREN® RW
EN 50264-2-1 600V M FR
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
VARPREN® RW
EN 50264-2-1 1800V M FR
Temperature:
- 40°C to + 90°C
Rated voltage:
1.8 /3 kV
Material:
Varpren®
VARPREN® RW
EN 50264-2-2 300V MM FR
Temperature:
- 40°C to + 90°C
Rated voltage:
300/500 V
Material:
Varpren®
VARPREN® RW
EN 50264-2-2 600V MM FR
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
VARPREN® RW
EN 50264-2-2 300V MM S FR
Temperature:
- 40°C to + 90°C
Rated voltage:
300/500 V
Material:
Varpren®
Shielding:
tin-plated copper braid
VARPREN® RW
EN 50264-2-2 600V MM S FR
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
Shielding:
tin-plated copper braid
VARPREN® RW
EN 50264-3-1 600V M FR
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
VARPREN® RW
EN 50264-3-1 1800V M FR
Temperature:
- 40°C to + 90°C
Rated voltage:
1.8 /3 kV
Material:
Varpren®
VARPREN® RW
EN 50264-3-2 300V MM FR
Temperature:
- 40°C to + 90°C
Rated voltage:
300/500 V
Material:
Varpren®
VARPREN® RW
EN 50264-3-2 600V MM FR
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
VARPREN® RW
EN 50264-3-2 300V MM S FR
Temperature:
- 40°C to + 90°C
Rated voltage:
300/500 V
Material:
Varpren®
Shielding:
tin-plated copper braid
VARPREN® RW
EN 50264-3-2 600V MM S FR
Temperature:
- 40°C to + 90°C
Rated voltage:
600/1000 V
Material:
Varpren®
Shielding:
tin-plated copper braid
PRODUCTS
SPECIFICATIONS
SILIGAINE®
15C7 GRADE A UL
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 7 kV (dry)
Material:
fiberglass with silicone coating
Approval:
UL
SILIGAINE®
TN FR
Temperature:
-50°C to +150°C
Material:
single-filament polyester
Version:
expandable
Approval:
EN 45545-2
Fire-smoke:
Flame resistant
SILIGAINE®
TN FR TWIST
Temperature:
-50°C to +150°C
Material:
single-filament polyester
Version:
expandable and self wrapping
Approval:
EN 45545-2
Fire-smoke:
Flame resistant
SILIGAINE®
TNL FR TWIST
Temperature:
-50°C to +150°C
Material:
single-filament polyester
Version:
expandable and self wrapping
Approval:
EN 45545-2
Fire-smoke:
Flame resistant
SILITUBE®
X - FIREPROOF SLEEVING
Temperature:
- 60°C to + 260°C (1 min 1500°C)
Material:
mineral fibre with silicone coating
Version:
improved fire performance
PRODUCTS
SPECIFICATIONS
DATARAIL®
100BE85EM101 4x0.5 mm²
Temperature:
- 25°C to + 85°C
Impedance:
100 ohms
Material:
halogen free
Shielding:
double: tape and braid
Version:
improved fire performance
Specific:
EN 45545-2

Heavy Industry

Wires and cables resistant to temperatures of up to +1400°C, High-temperature braided sleevings

The OMERIN Group is a major player in the Heavy Industry sector (Metallurgy, Glass Works, Ironworks, etc.). The Group is Europe’s leading manufacturer of glass yarn. Our product ranges SILICABLE® (silicone-insulated wires and cables with or without reinforcing braid), SILIFLAM® THS (very high safety cables with composite insulation) and SILIGAINE® (braided insulating sleevings) are designed to withstand extreme conditions of up to +1400°C. They have been designed in particular to power industrial facilities and maintain them operational in the most severe operating conditions. They can also be employed in areas where the ambient conditions may vary occasionally or due to an accident and reach abnormal levels. Our products comply with the main international standards and certifications: UL, CSA to guarantee top-notch reliability and quality.

PRODUCTS
SPECIFICATIONS
SILICABLE®
SIR-IDC
Temperature:
- 60°C to + 180°C
Rated voltage:
300/300 V
Material:
silicone
Approval:
VDE
SILICABLE®
CS-ES, ECS-ES
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V, 600/1000 V
Material:
silicone
Core:
extra flexible
SILICABLE®
CSC, ECSC
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V
Material:
silicone
SILICABLE®
ECSC-VDE, CNCSC-VDE
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V
Material:
silicone
SILICABLE®
CS-THT, ECS-THT
Temperature:
- 60°C to + 250°C
Rated voltage:
300/500 V
Material:
silicone
Core:
flexible
SILICABLE®
RCS-THT, RECS-THT
Temperature:
- 60°C to + 250°C
Rated voltage:
300/500 V
Material:
silicone
Core:
rigid
SILICABLE®
CS-HRD, ESC-HRD
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V
Material:
silicone
Version:
improved mechanical strength
SILICABLE®
CS-FRNC
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V
Material:
silicone
SILICABLE®
CS-HT
Temperature:
- 60°C to + 180°C
Rated voltage:
15 to 30 kV
Material:
silicone
SILICABLE®
MC-ECS
Temperature:
- 60°C to + 180°C
Rated voltage:
600/1000 V
Material:
silicone
SILICABLE®
MCBE-ECS
Temperature:
- 60°C to + 180°C
Rated voltage:
600/1000 V
Material:
silicone
Shielding:
tin-plated copper braid
SILICABLE®
MCBAL-ECS
Temperature:
- 60°C to + 180°C
Rated voltage:
600/1000 V
Material:
silicone
Version:
screened
SILICABLE®
MC-HRD
Temperature:
- 60°C to + 180°C
Rated voltage:
600/1000 V
Material:
silicone
Version:
improved mechanical strength
SILICABLE®
MCBE-HRD
Temperature:
- 60°C to + 180°C
Rated voltage:
600/1000 V
Material:
silicone
Shielding:
tin-plated copper braid
Version:
improved mechanical strength
SILICABLE®
MC-EFEP
Temperature:
- 60°C to + 200°C
Rated voltage:
300/500 V
Material:
silicone (fluoropolymer insulation)
SILICABLE®
MCBE-EFEP
Temperature:
- 60°C to + 200°C
Rated voltage:
300/500 V
Material:
silicone (fluoropolymer insulation)
Shielding:
tin-plated copper braid
SILICABLE®
Style 4389-S200
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 4389-S200 VW-1
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 4476-S200
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone
Approval:
UL
SILICABLE®
Style 4421-S200
Temperature:
- 60°C to + 200°C
Rated voltage:
300, 600, 1000 V
Material:
silicone
Approval:
UL
SILICABLE®
CSV, ECSV
Temperature:
- 60°C to + 200°C
Rated voltage:
300/500 V, 600/1000 V
Material:
silicone with reinforcing braid
Core:
flexible
SILICABLE®
CSVRI, ECSVRI
Temperature:
- 60°C to + 220°C
Rated voltage:
450/750 V
Material:
silicone with reinforcing braid
Core:
flexible
Version:
designed for stripping on automatic machines
SILICABLE®
Style 3535
Temperature:
- 60°C to + 150°C
Rated voltage:
600 V
Material:
silicone with reinforcing braid
Approval:
UL
SILICABLE®
Style 3122
Temperature:
- 60°C to + 200°C
Rated voltage:
300 V
Material:
silicone with reinforcing braid
Approval:
UL
SILICABLE®
Style 3122 VW-1
Temperature:
- 60°C to + 200°C
Rated voltage:
300 V
Material:
silicone with reinforcing braid
Approval:
UL
SILICABLE®
Style 3071
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone with reinforcing braid
Approval:
UL
SILICABLE®
Style 3513
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone with reinforcing braid
Approval:
UL
SILICABLE®
Style 3513 VW-1
Temperature:
- 60°C to + 200°C
Rated voltage:
600 V
Material:
silicone with reinforcing braid
Approval:
UL
SILICABLE®
Style 3645
Temperature:
- 60°C to + 200°C
Rated voltage:
1000 V (cUL 600 V)
Material:
silicone with reinforcing braid
Approval:
UL
SILICABLE®
CSVCS, ECSVCS
Temperature:
- 60°C to + 180°C
Rated voltage:
300/500 V
Material:
silicone with reinforcing braid
Version:
double insulating layer
SILICABLE®
CSP, ECSP
Temperature:
- 60°C to + 180°C
Rated voltage:
450/750 V, 600/1000 V
Material:
silicone with reinforcing braid
SILICABLE®
ECSPRI
Temperature:
- 60°C to + 180°C
Rated voltage:
600/1000 V
Material:
silicone with reinforcing braid
SILICABLE®
VMC-ECS
Temperature:
- 60°C to + 180°C
Rated voltage:
600/1000 V
Material:
silicone with reinforcing braid
SILICABLE®
PMC-ECS
Temperature:
- 60°C to + 180°C
Rated voltage:
600/1000 V
Material:
silicone with reinforcing braid
SILICABLE®
PMCBEC-ECS
Temperature:
- 60°C to + 180°C
Rated voltage:
600/1000 V
Material:
silicone with reinforcing braid
Core:
flexible
Shielding:
tin-plated copper braid
SILICABLE®
ECSBECSP
Temperature:
- 60°C to + 180°C
Rated voltage:
600/1000 V
Material:
silicone with reinforcing braid
Core:
flexible
Shielding:
tin-plated copper braid
SILICABLE®
Style 3779
Temperature:
- 60°C to + 180°C
Rated voltage:
600 V
Material:
silicone with reinforcing braid
Approval:
UL
SILICABLE®
Style 5167
Temperature:
- 60°C to + 250°C
Rated voltage:
300 V
Material:
composites
Core:
nickel-plated copper or nickel
Approval:
UL
SILICABLE®
Style 5257
Temperature:
- 60°C to + 250°C
Rated voltage:
300 V
Material:
composites
Core:
nickel-plated copper or nickel
Approval:
UL
SILICABLE®
Style 5256
Temperature:
- 60°C to + 250°C
Rated voltage:
600 V
Material:
composites
Core:
nickel-plated copper or nickel
Approval:
UL
SILICABLE®
Style 5196
Temperature:
- 60°C to + 250°C
Rated voltage:
600 V
Material:
composites
Core:
nickel-plated copper or nickel
Approval:
UL
SILICABLE®
Style 5125
Temperature:
- 60°C to + 250°C
Rated voltage:
600 V
Material:
composites
Core:
nickel-plated copper or nickel
Approval:
UL
SILICABLE®
CN2K
Temperature:
- 190°C to + 250°C
Rated voltage:
300/500 V
Material:
two heat-sealed crossed polyimide tapes
Core:
bare copper
SILICABLE®
CN4K
Temperature:
- 190°C to + 250°C
Rated voltage:
300/500 V
Material:
four heat-sealed crossed polyimide tapes
Core:
bare copper
PRODUCTS
SPECIFICATIONS
PRODUCTS
SPECIFICATIONS
SILIFLAM®
THS 1000
Temperature:
+ 400°C to + 800°C (indicative values)
Rated voltage:
300/500 V to 600/1000 V
Material:
composites
SILIFLAM®
THS 1200
Temperature:
+ 500°C to + 1000°C (indicative values)
Rated voltage:
300/500 V to 600/1000 V
Material:
composites
SILIFLAM®
THS 1400
Temperature:
+ 700°C to + 1200°C (indicative values)
Rated voltage:
300/500 V to 600/1000 V
Material:
composites
SILIFLAM®
THS 1500
Temperature:
+ 900°C to + 1400°C (indicative values)
Rated voltage:
300/500 V to 600/1000 V
Material:
composites
SILIFLAM®
THS - Operating temperatures and parameters
Temperature:
until + 1400°C (indicative values)
Rated voltage:
300/500 V to 600/1000 V
PRODUCTS
SPECIFICATIONS
SILITUBE®
X - FIREPROOF SLEEVING
Temperature:
- 60°C to + 260°C (1 min 1500°C)
Material:
mineral fibre with silicone coating
Version:
improved fire performance
PRODUCTS
SPECIFICATIONS
SILIGAINE®
15C1.5
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
1.5 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C2
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
2.5 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C3
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 3 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C3-UV
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 3 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C4
Temperature:
- 60°C to + 250°C, Class H & C
Dielectric strength:
> 4 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C4.d
Temperature:
- 60°C to + 200°C, Class H
Dielectric strength:
> 4 kV (dry)
Material:
fiberglass (double insulation)
Version:
abrasion resistance
SILIGAINE®
15C5
Temperature:
- 60°C to + 200°C, Class H
Dielectric strength:
> 5 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
15C5-E EXTENSIBLE
Temperature:
- 60°C to + 200°C, Class H
Dielectric strength:
> 5 kV (dry)
Material:
fiberglass with silicone coating
Version:
expandable
SILIGAINE®
15C7 GRADE A UL
Temperature:
- 60°C to + 200°C, Class H
Dielectric strength:
> 7 kV (dry)
Material:
fiberglass with silicone coating
Approval:
UL
SILIGAINE®
15C10
Temperature:
- 60°C to + 200°C, Class H
Dielectric strength:
> 10 kV (dry)
Material:
fiberglass with silicone coating
SILIGAINE®
21F1
Temperature:
- 60°C to + 280°C
Dielectric strength:
0.8 to 1.2 kV (dry)
Material:
treated fiberglass with clear silicone varnish coating
SILIGAINE®
24C1
Temperature:
- 60°C to + 350°C
Dielectric strength:
0.8 to 1.2 kV (dry)
Material:
fiberglass treated and impregnated with silicone resin
SILIGAINE®
31-1
Temperature:
- 60°C to + 450°C
Material:
treated fiberglass
Version:
not impregnated
SILIGAINE®
31C1E EXTENSIBLE
Temperature:
- 60°C to + 350°C
Material:
fiberglass high temperature treated and impregnated
Version:
expandable and very flexible
SILIGAINE®
GT1
Temperature:
- 60°C to + 300°C
Dielectric strength:
> 800 V (dry)
Material:
treated fiberglass
Version:
not impregnated
SILIGAINE®
GTE 1
Temperature:
- 60°C to + 250°C
Dielectric strength:
> 1.5 kV (dry)
Material:
treated fiberglass
SILIGAINE®
33SI
Temperature:
+ 900°C (peak + 1050°C)
Material:
silica fibre
Version:
not treated, not impregnated
SILIGAINE®
GSIL
Temperature:
+ 1050°C (peak + 1200°C)
Material:
ultra pure silica fibre
Version:
not treated, not impregnated
SILIGAINE®
33NX
Temperature:
+ 1200°C (peak + 1400°C)
Material:
borosilicoaluminate fibre
Version:
not treated, not impregnated

Marine and Shipbuilding

Low-voltage electrical wires and cables, Flexible medium-voltage cables, Instrumentation and control cables

The OMERIN Group is a recognised specialist in the Marine and Shipbuilding sector. Our ranges of wires and cables VARPREN® (Varpren® elastomer-insulated electrical wires), MULTIMAX® (HFFR sheathed multi-conductor cables) and SILICOUL® (flexible single conductor cables 1.1 to 15 kV) offer excellent solutions for the special applications of the Merchant Marine and Military sectors. Our products comply with the main international standards and certifications: Bureau Veritas Marine, Lloyd’s register, UL, CSA to guarantee top-notch reliability and quality.

PRODUCTS
SPECIFICATIONS
VARPREN®
MAX
Temperature:
- 30°C to 125°C
Rated voltage:
600/1000 V
Material:
Varpren®
PRODUCTS
SPECIFICATIONS
SILICABLE®
PMCBEC-ECS
Temperature:
- 60°C to + 180°C
Rated voltage:
600/1000 V
Material:
silicone with reinforcing braid
Core:
flexible
Shielding:
tin-plated copper braid
SILICABLE®
ECSBECSP
Temperature:
- 60°C to + 180°C
Rated voltage:
600/1000 V
Material:
silicone with reinforcing braid
Core:
flexible
Shielding:
tin-plated copper braid
MULTIMAX®
CF
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
halogen free
MULTIMAX®
CF BL
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
halogen free
Version:
armoured
MULTIMAX®
CF 331
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
halogen free
MULTIMAX®
CF BL 331
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
halogen free
Version:
armoured
PRODUCTS
SPECIFICATIONS
SILICOUL®
1.1 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
Lloyd's register & BV
SILICOUL®
3.7 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
Lloyd's register
SILICOUL®
6.6 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
Lloyd's register
SILICOUL®
13.8 KV
Temperature:
- 60°C to + 180°C
Material:
silicone with reinforcing braid
Approval:
Lloyd's register
PRODUCTS
SPECIFICATIONS
MULTIMAX®
CI
Temperature:
- 30°C to + 80°C
Rated voltage:
150/250 V
Material:
halogen free
MULTIMAX®
CI EG / EI
Temperature:
- 30°C to + 80°C
Rated voltage:
150/250 V
Material:
halogen free
Version:
sreened
MULTIMAX®
CI BL
Temperature:
- 30°C to + 80°C
Rated voltage:
150/250 V
Material:
halogen free
Version:
armoured
MULTIMAX®
CI BL EG / EI
Temperature:
- 30°C to + 80°C
Rated voltage:
150/250 V
Material:
halogen free
Version:
sreened
MULTIMAX®
CI 331
Temperature:
- 30°C to + 80°C
Rated voltage:
150/250 V
Material:
halogen free
MULTIMAX®
CI 331 EG / EI
Temperature:
- 30°C to + 80°C
Rated voltage:
150/250 V
Material:
halogen free
Version:
sreened
MULTIMAX®
CI BL 331
Temperature:
- 30°C to + 80°C
Rated voltage:
150/250 V
Material:
halogen free
Version:
armoured
MULTIMAX®
CI BL 331 EG / EI
Temperature:
- 30°C to + 80°C
Rated voltage:
150/250 V
Material:
halogen free
Version:
sreened

Pyrometric Applications

Thermocouple, extension and compensation cables, PT100 Sensor connection cables

The OMERIN Group is a major player in the Temperature Measurement sector. Our range of COUPLIX® (thermocouple, extension and compensation cables) and SONDIX® (connection cables for platinum resistance temperature sensors) cables offers an excellent solution for temperature measurement techniques with thermocouples or resistance temperature sensors. Our products comply with the main marking standards and international certifications in the pyrometry sector: IEC 60584, ANSI-MC96.1, JIS C 1610, IEC 60751, NF C 43-330, DIN 43760, BS 1904, UL, CSA… to guarantee top-notch reliability and quality. Lastly, our engineers recently developed a particularly innovative pyrometry cable, the COUPLIX® K/KX-M-8 and E/EX-M-8: miniature, ceramic-insulated, ultra-light and resistant to extremely high temperatures.

PRODUCTS
SPECIFICATIONS
COUPLIX®
ZH JX, KX, EX, TX, BC, KCB
Temperature:
- 30°C to + 80°C
Couple:
JX, TX, KX, EX, BC, KCB
Material:
HFFR
COUPLIX®
HT JX, KX, EX, TX, BC, KCB
Temperature:
- 60°C to + 200°C
Couple:
JX, TX, KX, EX, BC, KCB
Material:
silicone
COUPLIX®
FR JX, KX, EX, TX, BC, KCB
Temperature:
- 30°C to + 80°C
Couple:
JX, TX, KX, EX, BC, KCB
Material:
HFFR
COUPLIX®
LH JX, KX, EX, TX, BC, KCB
Temperature:
- 30°C to + 80°C
Couple:
JX, TX, KX, EX, BC, KCB
Material:
thermoplastic PVC
COUPLIX®
RH JX, KX, EX, TX, BC, KCB
Temperature:
- 30°C to + 80°C
Couple:
JX, TX, KX, EX, BC, KCB
Material:
thermoplastic PVC
COUPLIX®
Main products COUPLES T, J, E, K, N
Temperature:
- 190°C to + 400°C (depending on references)
Couple:
T, J, E, K, N
Material:
PVC, FEP, PFA, fiberglass, silica fibre, borosilicoaluminate fibre...
Version:
Stainless steel, galvanized steel or tin-plated copper braids (optional)
COUPLIX®
Main products COUPLES KX1, JX1, NX1, EX1, SCA
Temperature:
- 190°C to + 400°C (depending on references)
Couple:
KX1, JX1, NX1, EX1, SCA
Material:
PVC, silicone, FEP, PFA, fiberglass, polyimide...
Version:
Stainless steel, galvanized steel or tin-plated copper braids (optional)
PRODUCTS
SPECIFICATIONS
SONDIX®
MC-ETFE, MC-EETFE
Temperature:
- 60°C to + 150°C
Rated voltage:
300V
Material:
ETFE
Version:
shielded (option)
SONDIX®
MC-EFEP, MC-AFEP
Temperature:
- 60°C to + 200°C
Rated voltage:
300V
Material:
FEP
Version:
shielded (option)
SONDIX®
MC-EPFA, MC-APFA, MC-CNPFA
Temperature:
- 60°C to + 260°C
Rated voltage:
300V
Material:
PFA
Version:
shielded (option)
SONDIX®
MC-ECS
Temperature:
- 60°C to + 200°C
Rated voltage:
300V
Material:
silicone
Version:
shielded (option)
SONDIX®
Main products
Temperature:
- 190°C to + 400°C (depending on references)
Material:
PVC, silicone, FEP, PFA, fiberglass...
PRODUCTS
SPECIFICATIONS
COUPLIX®
K/KX-M-8, E/EX-M-8
Temperature:
- 90°C to + 500°C (peak + 1000°C)
Couple:
E, K
Material:
ceramic
Version:
thermocouple
Size:
miniature
COUPLIX®
KX-M-EE
Temperature:
- 55°C to + 260°C
Couple:
KX
Material:
Polyimide / PTFE
Version:
thermocouple, inspired of EN 2714
Size:
miniature

Robotics and Automation

Specialised moving cables and cords: alternate bending, folding, twisting, cable carrier, traction, mechanical impacts, etc.

Expert in specialised moving cables, CGP, a subsidiary of the OMERIN Group, has made a name for itself in the industrial Robotics and Automation sector. Our OMBILIFLEX® (special multi-functional cables) and SPIRFLEX® (spiral cords) ranges are custom-made products offering extremely high performance, and which are adapted to the specific needs and operational limitations of our customers. A full array of mechanical tests (cable carrier, folding, twisting, traction, combined movements) are performed over millions of cycles at our laboratories to guarantee the optimal service life for our products. Also discover our new range HIFLEX® of standard moving cables (cables in motion for cable chain, alternate bending or torsion flexion) designed to work in motion on very large cycles up to 5 million, our HIFLEX® power and control cables are available in single-core, multi-core versions, with or without shielding.

PRODUCTS
SPECIFICATIONS
OMBILIFLEX®
Special multi-function cables
Composition:
umbilical cable
Version:
customized product
Specific:
multi-function ernergy, signal, fluid, traction...
PRODUCTS
SPECIFICATIONS
HIFLEX®
TF5 CONTROL
Composition:
multi-core
Temperature:
- 20°C to + 90°C
Rated voltage:
500 V
Material:
polyurethane
Core:
extra flexible bare copper, class 6
Specific:
5 million cycles in flexion and torsion
HIFLEX®
TF5 BE CONTROL
Composition:
multi-core
Temperature:
- 20°C to + 90°C
Rated voltage:
500 V
Material:
polyurethane
Core:
extra flexible bare copper, class 6
Shielding:
tin-plated copper spiral shield
Specific:
5 million cycles in flexion and torsion
PRODUCTS
SPECIFICATIONS
HIFLEX®
FX5 CONTROL
Composition:
multi-core
Temperature:
- 20°C to + 90°C
Rated voltage:
500 V
Material:
polyurethane
Core:
extra flexible bare copper, class 6
Version:
halogen free
Specific:
5 million cycles in alternate bending
PRODUCTS
SPECIFICATIONS
HIFLEX®
CH2 POWER
Composition:
single-core
Temperature:
- 20°C to + 90°C
Rated voltage:
1000 V
Material:
extra flexible PVC
Core:
flexible bare copper, class 5
Specific:
2 million cycles in cable carrier chains
HIFLEX®
CH5 POWER
Composition:
single-core
Temperature:
- 20°C to + 90°C
Rated voltage:
1000 V
Material:
polyurethane
Core:
flexible bare copper, class 5
Version:
halogen free
Specific:
5 million cycles in cable carrier chains
HIFLEX®
CH5 BE POWER
Composition:
single-core
Temperature:
- 20°C to + 90°C
Rated voltage:
1000 V
Material:
polyurethane
Core:
flexible bare copper, class 5
Shielding:
tin-plated copper braid
Version:
halogen free
Specific:
5 million cycles in cable carrier chains
HIFLEX®
CH2 CONTROL
Composition:
multi-core
Temperature:
- 20°C to + 90°C
Rated voltage:
500 V
Material:
extra flexible PVC
Core:
extra flexible bare copper, class 6
Specific:
2 million cycles in cable carrier chains
HIFLEX®
CH5 CONTROL
Composition:
multi-core
Temperature:
- 20°C to + 90°C
Rated voltage:
500 V
Material:
polyurethane
Core:
extra flexible bare copper, class 6
Version:
halogen free
Specific:
5 million cycles in cable carrier chains
HIFLEX®
CH5 BE CONTROL
Composition:
multi-core
Temperature:
- 20°C to + 90°C
Rated voltage:
500 V
Material:
polyurethane
Core:
extra flexible bare copper, class 6
Shielding:
tin-plated copper braid
Version:
halogen free
Specific:
5 million cycles in cable carrier chains
PRODUCTS
SPECIFICATIONS
SPIRFLEX®
High performance spiral cables
Composition:
spiral cables
Version:
customized product
Specific:
fitted with or without connectors
PRODUCTS
SPECIFICATIONS
OILPLAST®
YSL-JZ
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Resistance:
to oils and industrial solvents
OILPLAST®
JZ LSZH
Temperature:
- 20°C to + 70°C
Rated voltage:
300/500 V
Material:
halogen free
OILPLAST®
YSL-C
Temperature:
- 20°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Shielding:
tin-plated copper braid
Resistance:
to oils and industrial solvents
OILPLAST®
YSL-Q
Temperature:
- 15°C to + 70°C
Rated voltage:
300/500 V
Material:
PVC
Version:
armoured
Resistance:
to oils and industrial solvents
OILPLAST®
YSL-EB
Temperature:
- 15°C to + 70°C
Rated voltage:
50 V A.C / 75 V D.C
Material:
PVC
Use:
intrinsic safety
OILPLAST®
YSL-EB-CY
Temperature:
- 15°C to + 70°C
Rated voltage:
50 V A.C / 75 V D.C
Material:
PVC
Shielding:
tin-plated copper braid
Use:
intrinsic safety
PRODUCTS
SPECIFICATIONS
ROBOFLEX®
41Qb
Temperature:
- 50°C to + 105°C
Rated voltage:
600/1000 V
Material:
TPE / Polyurethane
Core:
classe 6, extra flexible
Version:
double insulation
ROBOFLEX®
MQb-41
Temperature:
- 50°C to + 105°C
Rated voltage:
300/500 V, 450/750 V
Material:
TPE / Polyurethane
Core:
classe 6, extra flexible
ROBOFLEX®
MQbBE-41
Temperature:
- 50°C to + 105°C
Rated voltage:
300/500 V, 450/750 V
Material:
TPE / Polyurethane
Core:
classe 6, extra flexible
Shielding:
tin-plated copper braid

Fire Safety

Fire-resistant power, telecommunication and instrumentation cables to ensure fire safety

The OMERIN Group is France’s leading manufacturer of Fire Safety cables. Our PYRISOL®, PYRITEL® and SILIFLAM® cables are fire resistant and fire retardant as per the CR1 and C1 tests from the NF C 32-070 standard, guaranteeing top-notch safety and reliability. Our offer of fire-resistant CR1 C1 wires and cables is the most comprehensive on the market. Our solutions are installed in the fire safety systems of public and high-rise buildings. We also offer a range of fire-resistant safety cables for the Belgian market that comply with the NBN C 30-004 standard. Find below all our CR1 fire-resistant products: 500 V power cable, 1000 V power cable, 500 V power armoured cable, telecommunication cable and instrumentation cable. For more information contact our teams dedicated to the fire safety market.

PRODUCTS
SPECIFICATIONS
PYRISOL®
500 EN CR1-C1
Rated voltage:
300/500 V
Material:
fire resistant
PYRISOL®
500 ENA CR1-C1
Rated voltage:
300/500 V
Material:
fire resistant
Version:
armoured
PYRISOL®
500 BEL
Rated voltage:
300/500 V
Material:
fire resistant
SILIFLAM®
500 TX-K CR1-C1
Rated voltage:
300/500 V
Material:
fire resistant
Core:
flexible
SILIFLAM®
500 TX-K BE CR1-C1
Rated voltage:
300/500 V
Material:
fire resistant
Core:
flexible
Shielding:
tin-plated copper braid
ELECTROFEU®
ET2002SH CR1-C1 1000V
Rated voltage:
600/1000 V
Material:
fire resistant
PRODUCTS
SPECIFICATIONS
PYRITEL®
100 EN CR1-C1
Rated voltage:
100/170 V
Material:
fire resistant
Version:
sreened
PYRITEL®
100 BEL
Rated voltage:
100/170 V
Material:
fire resistant
Version:
sreened
SILIFLAM®
500 TEL-EI/EG CR1-C1
Rated voltage:
100/170 V
Material:
fire resistant
Version:
sreened

High-Risk Sites

Halogen-free cables, Fire-resistant cables, High-temperature Cables, Hydrocarbon-resistant cables, Offshore cables

Thermal power stations fired by biomass, fossil-fuel (coal, heating oil, natural gas) or nuclear-powered, hydroelectric power plants, tidal turbines and solar farms, zones with explosive atmospheres (ATEX), refineries and offshore oil rigs… All of these sites have one major concern in common: safety. Fully aware of this problem, OMERIN Group’s R&D department has developed ENERSYL® cables that can withstand the most extreme conditions and meet the most stringent requirements (fire, high temperatures, hydrocarbons, salt spray, etc.) while meeting all of these sites’ needs for their various applications: power cables, control cables, instrumentation cables, pyrometry cables. ENERSYL® is an innovative and comprehensive offer for our customers, manufacturers, fitters and maintenance supervisors at power plants and high-risk sites.

PRODUCTS
SPECIFICATIONS
ENERSYL®
LH POWER 1x
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
thermoplastic PVC
ENERSYL®
LH POWER Multi
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
thermoplastic PVC
ENERSYL®
LH CONTROL
Temperature:
- 30°C to + 80°C
Rated voltage:
450/750 V
Material:
thermoplastic PVC
ENERSYL®
LH INSTRUM
Temperature:
- 30°C to + 80°C
Rated voltage:
300/500 V
Material:
thermoplastic PVC
Shielding:
braid and/or tape
COUPLIX®
LH JX, KX, EX, TX, BC, KCB
Temperature:
- 30°C to + 80°C
Couple:
JX, TX, KX, EX, BC, KCB
Material:
thermoplastic PVC
PRODUCTS
SPECIFICATIONS
ENERSYL®
ZH POWER 1x
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
HFFR
ENERSYL®
ZH POWER Multi
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
HFFR
ENERSYL®
ZH CONTROL
Temperature:
- 30°C to + 80°C
Rated voltage:
450/750 V
Material:
HFFR
ENERSYL®
ZH INSTRUM
Temperature:
- 30°C to + 80°C
Rated voltage:
300/500 V
Material:
HFFR
Shielding:
braid and/or tape
COUPLIX®
ZH JX, KX, EX, TX, BC, KCB
Temperature:
- 30°C to + 80°C
Couple:
JX, TX, KX, EX, BC, KCB
Material:
HFFR
PRODUCTS
SPECIFICATIONS
ENERSYL®
FR POWER 1x
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
HFFR
ENERSYL®
FR POWER Multi
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
HFFR
ENERSYL®
FR CONTROL
Temperature:
- 30°C to + 80°C
Rated voltage:
450/750 V
Material:
HFFR
ENERSYL®
FR INSTRUM
Temperature:
- 30°C to + 80°C
Rated voltage:
300/500 V
Material:
HFFR
Shielding:
braid and/or tape
COUPLIX®
FR JX, KX, EX, TX, BC, KCB
Temperature:
- 30°C to + 80°C
Couple:
JX, TX, KX, EX, BC, KCB
Material:
HFFR
PRODUCTS
SPECIFICATIONS
PROFIPLAST®
RH EG SF
Temperature:
- 30°C to + 90°C
Rated voltage:
150 V A.C / 220 V D.C
Material:
PVC HR
Version:
sreened
Resistance:
hydrocarbons
PROFIPLAST®
RH EG FA
Temperature:
- 30°C to + 90°C
Rated voltage:
150 V A.C / 220 V D.C
Material:
PVC HR
Version:
screened and armoured
Resistance:
hydrocarbons
PROFIPLAST®
RH EI SF
Temperature:
- 30°C to + 90°C
Rated voltage:
150 V A.C / 220 V D.C
Material:
PVC HR
Version:
sreened
Resistance:
hydrocarbons
PROFIPLAST®
RH EI FA
Temperature:
- 30°C to + 90°C
Rated voltage:
150 V A.C / 220 V D.C
Material:
PVC HR
Version:
screened and armoured
Resistance:
hydrocarbons
ENERSYL®
RH POWER 1x
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
thermoplastic PVC
ENERSYL®
RH POWER Multi
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
thermoplastic PVC
ENERSYL®
RH CONTROL
Temperature:
- 30°C to + 80°C
Rated voltage:
450/750 V
Material:
thermoplastic PVC
ENERSYL®
RH INSTRUM
Temperature:
- 30°C to + 80°C
Rated voltage:
300/500 V
Material:
thermoplastic PVC
Version:
sreened
COUPLIX®
RH JX, KX, EX, TX, BC, KCB
Temperature:
- 30°C to + 80°C
Couple:
JX, TX, KX, EX, BC, KCB
Material:
thermoplastic PVC
PRODUCTS
SPECIFICATIONS
ENERSYL®
OS SHF1 POWER 1x
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
halogen free
ENERSYL®
OS SHF1 POWER Multi
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
halogen free
ENERSYL®
OS SHF1 CONTROL
Temperature:
- 30°C to + 80°C
Rated voltage:
450/750 V
Material:
halogen free
ENERSYL®
OS SHF1 INSTRUM
Temperature:
- 30°C to + 80°C
Rated voltage:
300/500 V
Material:
halogen free
ENERSYL®
OS 331 SHF1 POWER 1x
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
halogen free
ENERSYL®
OS 331 SHF1 POWER Multi
Temperature:
- 30°C to + 80°C
Rated voltage:
600/1000 V
Material:
halogen free
ENERSYL®
OS 331 SHF1 CONTROL
Temperature:
- 30°C to + 80°C
Rated voltage:
450/750 V
Material:
halogen free
ENERSYL®
OS 331 SHF1 INSTRUM
Temperature:
- 30°C to + 80°C
Rated voltage:
300/500 V
Material:
halogen free
PRODUCTS
SPECIFICATIONS
ENERSYL®
HT POWER 1x
Temperature:
- 60°C to + 200°C
Rated voltage:
600/1000 V
Material:
silicone
ENERSYL®
HT POWER Multi
Temperature:
- 60°C to + 200°C
Rated voltage:
600/1000 V
Material:
silicone
ENERSYL®
HT CONTROL
Temperature:
- 60°C to + 200°C
Rated voltage:
450/750 V
Material:
silicone
ENERSYL®
HT INSTRUM
Temperature:
- 60°C to + 200°C
Rated voltage:
300/500 V
Material:
silicone
Shielding:
braid and/or tape
COUPLIX®
HT JX, KX, EX, TX, BC, KCB
Temperature:
- 60°C to + 200°C
Couple:
JX, TX, KX, EX, BC, KCB