Rheonik RHM 20 Flow Sensor
The RHM 20 is a 2″ meter designed for general purpose flow measurement without the need for maintenance. Robust and accurate, the RHM 20 outperforms other flow technologies at an attractively low cost of ownership.
- Range: 1 kg/min up to 480 kg/min
- Pressure: up to 400 bar (5801 psi)
- Temperature: -50°C (-58°F) up to +210°C (410°F)
- Accuracy: 0.1 % of rate
- Materials: SS 316L / SS 316Ti, Alloy C22 – 2.4602, Tantalum – UNS R05200, Super Duplex – 1.4410
- Process Connection: 1″ up to “
MFG Part Number | RHM-20 |
Stock | Limited |
General Specifications
Nominal Flow (Qnom)* | 300 kg/min (661.4 lb/min) |
Maximum Flow (Qmax)* | 480 kg/min (1058.22 lb/min) |
Typical Minimum Flow (Qmin)* | 1 kg/min (2.2 lb/min) |
Serial Tube / Single Path | Flow rates Qmax, Qnom and Qmin for “serial” sensors will be 50% of the above listed parallel/dual path version. |
Operating Temperature | Fluid temperature range options cover applications from -196°C to 350°C (-320°F to 662°F). |
Ambient Temperature | -50°C to +80°C (-60°F to +180°F) (standard), versions available for installation in vacuum chamber (-260°C / -430°F) or oven (up to +210°C / +410°F) (optional) |
Pressure Ratings | Up to 1379 bar / 20000 psi – dependent upon material |
Electrical Connection Sensor w/o Integral Transmitter |
M20 x 1.5 standard cable entry for JM, SM terminal box versions |
Sensor Enclosure Materials |
Stainless steel 304 (standard), SS 316 (optional) |
Enclosure Type | Protection class IP66, NEMA 4X (standard), IP66/67, NEMA 4X/6 (optional) |
Wetted Materials |
Flow tubes SS 316Ti, Alloy C22, Tantalum or SuperDuplex |
Process Connections | Nearly any – the Rheonik AnyPipeFit Commitment. Consult factory for types/sizes not listed in this data sheet on the Mechanical Construction pages |
Pressure Rating Compliance |
Europe – PED: Sound Engineering Practice (SEP), Module A2, Module B3.1+C2 |
Certifications and Approvals |
ATEX / IECEx Approvals for Zone 0, 1 (details see page 17) |
Testing and Inspection | All sensors are hydro tested, calibrated and supplied with a traceable calibration certificate. Customized calibration and testing services are available |
Project Documentation and QA, Services |
Rheonik offers a full set of services for large and complex engineering projects.
|
Options |
Enclosure heating for high temperature applications |
Pressure Drop

At Qnom pressure drop across a parallel tube sensor will be approximately 1 bar (14 psi) for H2O. Sensors can be operated at higher flow rates up to Qmax but pressure drop will be higher. Typical Minimum Flow Qmin is the recommended lowest flow rate for an accurate measurement. Sensors will measure flow rates lower than Qmin but uncertainty will increase beyond 1% of rate.
The flow rate specifications above relate to standard pressure, parallel tube, manifold sensor versions. Models with higher pressure ratings have increased wall thickness and will have higher pressure drops.