Rheonik RHM 160 Flow Sensor

 

The RHM 160 is the ultimate cargo and pipeline meter. With a combination of high accuracy and low pressure drop, the RHM 160 is the perfect solution for rapidly transferring large fluid quanties with confidence.

  • Range: 250 kg/min up to 30000 kg/min
  • Pressure: up to 52 bar (754 psi)
  • Temperature: -196°C (-321°F) up to +120°C (248°F)
  • Accuracy: 0.1 % of rate
  • Materials: SS 316L / SS 316Ti, Alloy C22 – 2.4602
  • Process Connection: 12″ up to 12″
MFG Part Number RHM-160
Stock Limited
SKU RHEONIK-RHM-160 Category Tag

 

General Specifications

Nominal Flow (Qnom)* 30000 kg/min (66139 lb/min)
Minimum Flow (Qmin)* 750 kg/min (1653 lb/min)
Operating Temperature

Fluid from -196°C to 120°C (-320°F to 248°F), see options in Part Number Code
Ambient from -50°C to 80°C (-58°F to 176°F)

Pressure Ratings Up to 50 bar / 725 psi – dependent upon material
Electrical Connection Sensor w/o Integral Transmitter

Cable entry M25 x 1.5 (standard), M20 x 1.5, ½” NPT, ¾” NPT (optional)
Max. cable length to remote RHE transmitter 30m / 98ft

Sensor Enclosure Materials

Stainless steel (standard), 316 stainless steel (optional)
Epoxy coated aluminum terminal box (standard), SS 316 terminal box (optional)

Enclosure Type Protection class IP66 / NEMA 4X with Standard Temperature Range (Option N1/NA); IP65 / NEMA 4 for Extended Temperature Ranges (Option E3)
Wetted Materials

1.4571 (316Ti), 2.4602 (Alloy C22)
Additional/customer specific materials available upon request

Process Connections Nearly any – the RHEONIK AnyPipeFit Commitment. Consult factory for types/sizes not listed
Pressure Rating Compliance Europe – PED: Module B3.2+C2
Certifications and Approvals

ATEX / IECEx Approvals for zone 0, 1, 2 (suitably rated RHE transmitter required)
North American Approvals for Class I, Div. 1, Groups ABCD (suitably rated RHE transmitter required)
American Bureau of Shipping (ABS) Type Approval for use on marine vessels

Testing and Inspection All sensors are hydro tested, calibrated and supplied with a traceable calibration certificate. Customized calibration and testing services available
Project Documentation and QA, Services

Rheonik offers a full set of services for large and complex engineering projects.
Typical services offered are, but not limited to:

  • Certificates of origin and conformity, mill certificates.
  • Data books including WPAR, WQS, NDT, test & quality plans, functional testing, calibration procedures, customized packing, factory acceptance etc.
  • Painting to project specification.
  • Start up and commissioning services on/offshore.
Options

Enclosure heating for high temperature applications
Cleaning for oxygen service
Full service painting to project specifications – consult factory

* At Qnom pressure drop will be approximately 1 bar (14 psi) for H2O. Sensors can be operated at higher flow rates but pressure drop will be higher. Maximum recommended velocity (liquid) through the sensor is 15 m/s. Beyond this point, cavitation may occur. Qmin is the recommended lowest flow rate. Sensors will measure flow rates lower than Qmin, but uncertainty may increase beyond 0.5% of rate.

These flow rate and pressure drop statements relate to standard pressure tube sensor versions. Models with higher pressure ratings have increased wall thickness and will have higher pressure drops and lower Qnom values.

Downloads