Rheonik RHM 60 Flow Sensor

 

The RHM 60 is a robust sensor designed for 4″ line sizes. The availablity of a variety of wetted materials and wide pressure/temperature ratings allow use in applications throughout all industries.

  • Range: 30 kg/min up to 3000 kg/min
  • Pressure: up to 430 bar (6236 psi)
  • Temperature: -196°C (-321°F) up to +350°C (662°F)
  • Accuracy: 0.1 % of rate
  • Materials: SS 316L / SS 316Ti, Super Duplex – 1.4410, Alloy C22 – 2.4602
  • Process Connection: 4″ up to 4″
MFG Part Number RHM-60
Stock Limited
SKU RHEONIK-RHM-60 Category Tag

 

General Specifications

Nominal Flow (Qnom)* 2500 kg/min (5512 lb/min)
Maximum Flow (Qmax)* 3000 kg/min (6614 lb/min)
Typical Minimum Flow (Qmin)* 30 kg/min (66 lb/min)
Operating Temperature Fluid temperature range options cover applications from -196°C to +350°C (-320°F to +662°F). For integral transmitter versions please refer to transmitter datasheet
Ambient Temperature -50°C to +80°C (-60°F to +180°F) (standard)
Pressure Ratings Up to 490 bar / 7107 psi – dependent upon material
Electrical Connection Sensor w/o Integral Transmitter

M20 x 1.5 standard cable entry for JM, SM terminal box versions
Optional entries available : ½” NPT or M25 x 1.5 (only for SM) or ¾” NPT (only for SM)
Max. cable length to remote RHE transmitter 100 m / 328 ft

Sensor Enclosure Materials

Stainless steel 304 (standard), SS 316 (optional)
Coated aluminum terminal box, SS 316 terminal box (optional)

Enclosure Type Protection class IP66 / NEMA 4X with Standard Temperature Range (Option N1/NA); IP65 / NEMA 4 for Extended Temperature Ranges (Option E2 / E3 / H4)
Wetted Materials

1.4571 (SS 316Ti), 1.4410 (SuperDuplex) – standard
2.4602 (Alloy C22) – consult Factory
Additional/customer specific materials available upon request

Process Connections Nearly any – the Rheonik AnyPipeFit Commitment. Consult factory for types/sizes not listed
Pressure Rating Compliance

Europe – PED: Module A2, Module B3.1+C2
Canada – CRN: Canadian Registration Number

Certifications and Approvals

ATEX / IECEx Approvals for Zone 0, 1 (details see page 10)
North American Approvals Class I, Div. 1, 2, Gr. A,B,C,D, Zone 0, 1, 2
MID custody transfer approval (OIML R117)
American Bureau of Shipping (ABS) Product Type Approval for use on marine vessels

Testing and Inspection All sensors are hydro tested, calibrated and supplied with a traceable calibration certificate. Customized calibration and testing services are available
Project Documentation and QA, Services

Rheonik offers a full set of services for large and complex engineering projects.
Typical services offered are, but not limited to:

  • Certificates of origin and conformity, mill certificates.
  • Data books including WPAR, WQS, NDT, test & quality plans, functional testing, calibration procedures, customized packing, factory acceptance etc.
  • Painting to project specification.
  • Start up and commissioning services on/offshore.
Options

Enclosure heating for high temperature applications
Cleaning for oxygen service
For more consult factory

* At Qnom pressure drop across a parallel tube sensor will be approximately 0.5 bar (7 psi) for H2O. Sensors can be operated at higher flow rates up to Qmax but pressure drop will be higher. Typical Minimum Flow Qmin is the recommended lowest flow rate for an accurate measurement. Sensors will measure flow rates lower than Qmin but uncertainty will increase beyond 1 % of rate.

The flow rate specifications above relate to standard pressure, parallel tube, manifold sensor versions. Models with higher pressure ratings have increased wall thickness and will have higher pressure drops.

Pressure Drop
CSM Rheonik diagram

At Qnom, pressure drop across a parallel tube sensor will be approximately 1-3 bar (15-44 psi) for H2O. Sensors can be operated at higher flow rates but pressure drop will be higher. Qmin is the recommended lowest flow rate. Sensors will measure flow rates lower than Qmin, but uncertainty will increase beyond 0.5 % of rate.

The flow specifications above relate to standard pressure, parallel tube, manifold sensor versions. Models with higher pressure ratings have increased wall thickness and will have higher pressure drops.

Downloads