Rheonik RHM 60 Flow Sensor
The RHM 60 is a robust sensor designed for 4″ line sizes. The availablity of a variety of wetted materials and wide pressure/temperature ratings allow use in applications throughout all industries.
- Range: 30 kg/min up to 3000 kg/min
- Pressure: up to 430 bar (6236 psi)
- Temperature: -196°C (-321°F) up to +350°C (662°F)
- Accuracy: 0.1 % of rate
- Materials: SS 316L / SS 316Ti, Super Duplex – 1.4410, Alloy C22 – 2.4602
- Process Connection: 4″ up to 4″
MFG Part Number | RHM-60 |
Stock | Limited |
General Specifications
Nominal Flow (Qnom)* | 2500 kg/min (5512 lb/min) |
Maximum Flow (Qmax)* | 3000 kg/min (6614 lb/min) |
Typical Minimum Flow (Qmin)* | 30 kg/min (66 lb/min) |
Operating Temperature | Fluid temperature range options cover applications from -196°C to +350°C (-320°F to +662°F). For integral transmitter versions please refer to transmitter datasheet |
Ambient Temperature | -50°C to +80°C (-60°F to +180°F) (standard) |
Pressure Ratings | Up to 490 bar / 7107 psi – dependent upon material |
Electrical Connection Sensor w/o Integral Transmitter |
M20 x 1.5 standard cable entry for JM, SM terminal box versions |
Sensor Enclosure Materials |
Stainless steel 304 (standard), SS 316 (optional) |
Enclosure Type | Protection class IP66 / NEMA 4X with Standard Temperature Range (Option N1/NA); IP65 / NEMA 4 for Extended Temperature Ranges (Option E2 / E3 / H4) |
Wetted Materials |
1.4571 (SS 316Ti), 1.4410 (SuperDuplex) – standard |
Process Connections | Nearly any – the Rheonik AnyPipeFit Commitment. Consult factory for types/sizes not listed |
Pressure Rating Compliance |
Europe – PED: Module A2, Module B3.1+C2 |
Certifications and Approvals |
ATEX / IECEx Approvals for Zone 0, 1 (details see page 10) |
Testing and Inspection | All sensors are hydro tested, calibrated and supplied with a traceable calibration certificate. Customized calibration and testing services are available |
Project Documentation and QA, Services |
Rheonik offers a full set of services for large and complex engineering projects.
|
Options |
Enclosure heating for high temperature applications |
* At Qnom pressure drop across a parallel tube sensor will be approximately 0.5 bar (7 psi) for H2O. Sensors can be operated at higher flow rates up to Qmax but pressure drop will be higher. Typical Minimum Flow Qmin is the recommended lowest flow rate for an accurate measurement. Sensors will measure flow rates lower than Qmin but uncertainty will increase beyond 1 % of rate.
The flow rate specifications above relate to standard pressure, parallel tube, manifold sensor versions. Models with higher pressure ratings have increased wall thickness and will have higher pressure drops.
Pressure Drop

At Qnom, pressure drop across a parallel tube sensor will be approximately 1-3 bar (15-44 psi) for H2O. Sensors can be operated at higher flow rates but pressure drop will be higher. Qmin is the recommended lowest flow rate. Sensors will measure flow rates lower than Qmin, but uncertainty will increase beyond 0.5 % of rate.
The flow specifications above relate to standard pressure, parallel tube, manifold sensor versions. Models with higher pressure ratings have increased wall thickness and will have higher pressure drops.