Introduction
The Rheonik RHM 160 Coriolis Mass Flow Sensor is a high-capacity, high-performance Coriolis mass flow sensor engineered for demanding cargo transfer and pipeline applications where accuracy, reliability, and operational efficiency are critical. Designed to handle extremely high flow rates with exceptional measurement stability, the RHM 160 combines precision mass flow and density measurement with a low-pressure drop profile, making it ideal for bulk fluid transfer operations in oil & gas, chemical processing, and energy industries. Its robust construction and advanced sensor design ensure consistent performance under extreme process conditions, including cryogenic temperatures and high-pressure environments. With superior accuracy and material flexibility, the RHM 160 enables operators to achieve precise custody transfer, optimize process control, and maintain confidence in high-volume fluid handling operations.
- Flow Range: 250 kg/min up to 30,000 kg/min
- Maximum Pressure: up to 52 bar (754 psi)
- Operating Temperature: -196°C (-321°F) up to +120°C (248°F)
- Measurement Accuracy: ±0.1% of rate
- Wetted Materials: Stainless Steel 316L / 316Ti, Alloy C22 (2.4602)
- Process Connection: Up to 12″ (pipeline integration ready)
General Specifications
| Nominal Flow (Qnom)* | 30000 kg/min (66139 lb/min) |
| Minimum Flow (Qmin)* | 750 kg/min (1653 lb/min) |
| Operating Temperature |
Fluid from -196°C to 120°C (-320°F to 248°F), see options in Part Number Code |
| Pressure Ratings | Up to 50 bar / 725 psi – dependent upon material |
| Electrical Connection Sensor w/o Integral Transmitter |
Cable entry M25 x 1.5 (standard), M20 x 1.5, ½” NPT, ¾” NPT (optional) |
| Sensor Enclosure Materials |
Stainless steel (standard), 316 stainless steel (optional) |
| Enclosure Type | Protection class IP66 / NEMA 4X with Standard Temperature Range (Option N1/NA); IP65 / NEMA 4 for Extended Temperature Ranges (Option E3) |
| Wetted Materials |
1.4571 (316Ti), 2.4602 (Alloy C22) |
| Process Connections | Nearly any – the RHEONIK AnyPipeFit Commitment. Consult the factory for types/sizes not listed |
| Pressure Rating Compliance | Europe – PED: Module B3.2+C2 |
| Certifications and Approvals |
ATEX / IECEx Approvals for zone 0, 1, 2 (suitably rated RHE transmitter required) |
| Testing and Inspection | All sensors are hydro tested, calibrated and supplied with a traceable calibration certificate. Customized calibration and testing services available |
| Project Documentation and QA, Services |
Rheonik offers a full set of services for large and complex engineering projects.
|
| Options |
Enclosure heating for high temperature applications |
* At Qnom, the pressure drop will be approximately 1 bar (14 psi) for H2O. Sensors can be operated at higher flow rates but the pressure drop will be higher. The maximum recommended velocity (liquid) through the sensor is 15 m/s. Beyond this point, cavitation may occur. Qmin is the recommended lowest flow rate. Sensors will measure flow rates lower than Qmin, but uncertainty may increase beyond 0.5% of the rate.
These flow rate and pressure drop statements relate to standard pressure tube sensor versions. Models with higher pressure ratings have increased wall thickness and will have higher pressure drops and lower Qnom values.
Downloads